Maytag MGR7685AB Installation Guide

Maytag MGR7685AB Manual

Maytag MGR7685AB manual content summary:

  • Maytag MGR7685AB | Installation Guide - Page 1
    Range 10 Electronic Ignition System 10 Warming Drawer or Premium Storage Drawer 12 Storage Drawer 12 Oven Door 13 Complete Installation 13 GAS CONVERSIONS 14 LP Gas Conversion 14 Natural Gas Conversion 17 IMPORTANT: Save for local inspector's use. Installer: Leave installation instructions
  • Maytag MGR7685AB | Installation Guide - Page 2
    from a neighbor's phone. Follow the gas supplier's instructions. • If you cannot reach your gas supplier, call the fire department. - Installation and service must be performed by a qualified installer, service agency or the gas supplier. WARNING: Gas leaks cannot always be detected by smell
  • Maytag MGR7685AB | Installation Guide - Page 3
    anti-tip bracket if range is moved. Do not operate range without anti-tip bracket installed and engaged. Failure to follow these instructions can result in -joint compound resistant to LP gas ■ Noncorrosive leak-detection solution For LP/Natural Gas Conversions combination wrench ■ ½" combination
  • Maytag MGR7685AB | Installation Guide - Page 4
    home installations require: ■ When this range is installed in a mobile home, it must be secured according to the instructions NOTE*. E. 30¹⁄₈" (76.5 cm) min. opening width F. The shaded areas are recommended for installation of rigid gas pipe. G. 4¹⁄₂" (11.4 cm) H. 8" (20.3 cm) I. 17" (43.2 cm) J. 2"
  • Maytag MGR7685AB | Installation Guide - Page 5
    the manufacturer's instructions. Type of Gas Natural gas: This range is design-certified by CSA International for use with Natural gas or, after proper conversion, for use with LP gas. ■ This range is factory set for use with Natural gas. See "Gas Conversions" section. The model/serial rating plate
  • Maytag MGR7685AB | Installation Guide - Page 6
    model/serial rating plate. Line pressure testing above ½ psi gauge (14" WCP) The range and its individual shutoff valve must be disconnected from the gas The range must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas
  • Maytag MGR7685AB | Installation Guide - Page 7
    can tip the range and be killed. Install anti-tip bracket to floor or wall per installation instructions. Slide range back so rear range foot is the wall mounting method. If you are installing the range in a mobile home, you must secure the range to the floor. 3. Determine and mark centerline
  • Maytag MGR7685AB | Installation Guide - Page 8
    range using the following installation instructions. Explosion Hazard Use a new CSA International approved gas supply line. Install a shut-off valve. Securely tighten all gas include: licensed heating personnel, authorized gas company personnel, and authorized service personnel. Failure to do so can
  • Maytag MGR7685AB | Installation Guide - Page 9
    manual shutoff valve in the gas supply line. The valve is open when the handle is parallel to the gas pipe. A B WARNING Electrical Shock Hazard Plug into a grounded 3 prong outlet. Do not remove ground prong. Do not use an adapter. Do not use an extension cord. Failure to follow these instructions
  • Maytag MGR7685AB | Installation Guide - Page 10
    between the range and the mounting wall. Changes to the gas supply must be performed by a qualified service technician. If you need assistance or service, refer to the "Assistance or Service" section of the Use and Care Guide, or the cover or "Warranty" section of the User Instructions, for contact
  • Maytag MGR7685AB | Installation Guide - Page 11
    and Care Guide or User Instructions for proper operation of the oven controls. Adjust Oven Bake Burner Flame (if needed) 1. On models with a needs to be adjusted, locate the air shutter near the center rear of the range. Loosen the locking screw and rotate the air shutter until the proper flame
  • Maytag MGR7685AB | Installation Guide - Page 12
    B. Air shutter 4. Press CANCEL/OFF when finished. Warming Drawer or Premium Storage Drawer (on some models) Remove all items from inside the warming drawer or premium storage drawer, and allow the range to cool completely before attempting to remove the drawer. To Remove: 1. Open the warming drawer
  • Maytag MGR7685AB | Installation Guide - Page 13
    grounded 3 prong outlet. ■ Electrical supply is connected. ■ See "Troubleshooting" in the Use and Care Guide or User Instructions. 8. When the range has been on for 5 minutes, check for heat. If the range is cold, turn off the range and check that the gas supply line shutoff valve is open. ■ If the
  • Maytag MGR7685AB | Installation Guide - Page 14
    and engaged. Failure to follow these instructions can result in death or serious burns to children and adults. 1. Turn the manual shutoff valve to the closed position. B A C A. To range B. Manual shutoff valve "closed" position C. Gas supply line 2. Unplug range or disconnect power. To Convert
  • Maytag MGR7685AB | Installation Guide - Page 15
    pressure regulator cap. To Convert Surface Burners (Natural Gas to LP Gas) 1. Remove burner cap. 2. Using a Phillips or Quadrex® screwdriver, remove the burner base. NOTE: Reinstall one of the screws through the range cooktop to hold the orifice spud holder in place while removing and replacing
  • Maytag MGR7685AB | Installation Guide - Page 16
    A 8. Replace the "49" spud with a "57" spud. Install the LP gas bake burner orifice spud, turning it clockwise until snug. IMPORTANT: Do not overtighten. oven bottom panel with 2 screws. To Convert Oven Broil Burner (Natural Gas to LP Gas) 1. Remove the screw from the broil burner. 2. Remove the
  • Maytag MGR7685AB | Installation Guide - Page 17
    LP gas flames have a slightly yellow tip. 3. Refer to "Complete Installation" in the "Installation Instructions" section of this manual to complete this procedure. NOTE: Make sure to save the orifices that have just been replaced in the conversion. Tip Over Hazard A child or adult can tip the range
  • Maytag MGR7685AB | Installation Guide - Page 18
    Gas to Natural Gas) 1. Remove burner cap. 2. Using a Phillips or Quadrex® screwdriver, remove the burner base. NOTE: Reinstall one of the screws through the range N210 N200 N190 N185 N180 N155 N140 N110 NOTE: Refer to the Model Number and Serial Number Plate located on the oven frame behind the top
  • Maytag MGR7685AB | Installation Guide - Page 19
    bottom panel with 2 screws. To Convert Oven Broil Burner (LP Gas to Natural Gas) 1. Remove the screw from the broil burner. 2. Remove the Bake burner 7. Use a ³⁄₈" nut driver or combination wrench and turn the LP gas bake burner orifice spud counterclockwise to remove. The spud will be stamped with a
  • Maytag MGR7685AB | Installation Guide - Page 20
    is very important. Natural gas flames do not have yellow tips. 3. Refer to "Complete Installation" in the "Installation Instructions" section of this manual to complete this procedure. NOTE: Make sure to save the orifices that have just been replaced in the conversion. W10403809B © 2012. All rights
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

INSTALLATION INSTRUCTIONS
30" (76.2 CM) FREESTANDING GAS RANGES
Table of Contents
RANGE SAFETY
.............................................................................
2
INSTALLATION REQUIREMENTS
...............................................
3
Tools and Parts
............................................................................
3
Location Requirements
...............................................................
3
Electrical Requirements
...............................................................
5
Gas Supply Requirements
..........................................................
5
INSTALLATION INSTRUCTIONS
.................................................
7
Unpack Range
.............................................................................
7
Install Anti-Tip Bracket
................................................................
7
Make Gas Connection
.................................................................
8
Verify Anti-Tip Bracket Is Installed and Engaged
.......................
9
Level Range
...............................................................................
10
Electronic Ignition System
.........................................................
10
Warming Drawer or Premium Storage Drawer
.........................
12
Storage Drawer
..........................................................................
12
Oven Door
..................................................................................
13
Complete Installation
.................................................................
13
GAS CONVERSIONS
...................................................................
14
LP Gas Conversion
....................................................................
14
Natural Gas Conversion
............................................................
17
W10403809B
IMPORTANT:
Save for local inspector's use.
Installer:
Leave installation instructions with the homeowner.
Homeowner:
Keep installation instructions for future reference.