Miele DA 6480 Operating and Installation manual

Miele DA 6480 Manual

Miele DA 6480 manual content summary:

  • Miele DA 6480 | Operating and Installation manual - Page 1
    Operating and Installation Instructions Downdraft Ventilation System DA 6480, DA 6490 DAG 500, DAG 1000 To prevent accidents and appliance damage, read these instructions before installation or use. en - US, CA M.-Nr. 09 045 140
  • Miele DA 6480 | Operating and Installation manual - Page 2
    ¢15 10 Temperature warning 11 Cleaning and Care 12 Grease filters 13 After Sales Service 15 Installation instructions 17 Caring for the environment 19 Appliance dimensions 20 Installation 26 Installation with the DAG 1000 external blower 34 Air extraction 35 Electrical connection 37 2
  • Miele DA 6480 | Operating and Installation manual - Page 3
    and pass them on to any future user. Read these Instructions carefully before installing or using the Ventilation System. ~ you have questions, contact Miele. ~ b) Before servicing or cleaning the appliance, switch power off at the service panel and lock the service disconnecting means to prevent
  • Miele DA 6480 | Operating and Installation manual - Page 4
    IMPORTANT SAFETY INSTRUCTIONS ~ d) Before connecting the appliance to the power supply make sure ~ f) Only open the housing as described in the "Cleaning and care" section of this manual. Under no circumstances should any other parts of the housing be opened. Tampering with electrical connections
  • Miele DA 6480 | Operating and Installation manual - Page 5
    IMPORTANT SAFETY INSTRUCTIONS ,WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A COOKTOP GREASE FIRE, OBSERVE THE FOLLOWING*: ~ a) SMOTHER FLAMES with a close fitting lid,
  • Miele DA 6480 | Operating and Installation manual - Page 6
    IMPORTANT SAFETY INSTRUCTIONS Installation ,WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR between a cooktop and the ventilation system given in the "Appliance dimensions" section of this manual. If local building codes require a greater safety distance, follow their requirement. ~ i)
  • Miele DA 6480 | Operating and Installation manual - Page 7
    Functional description The ventilation system offers two installation options: with the internal DAG 500 exhaust blower (not included) with the DAG 1000 external blower (not included) The air is drawn through and cleaned by the grease filters and then directed outside. The air is drawn through
  • Miele DA 6480 | Operating and Installation manual - Page 8
    Description of the appliance 8
  • Miele DA 6480 | Operating and Installation manual - Page 9
    of the appliance a On/Off button for the retractable vent and fan b Control panel c Retractable vent d Grease filter e Exhaust blower DAG 500 (not included) The exhaust blower can also be installed behind the appliance. f Vent collar The vent collar can be installed so that the exhaust vents to
  • Miele DA 6480 | Operating and Installation manual - Page 10
    Operation Raising the vent / Turning on the fan ^ Press the On/Off button on the top of the ventilation system. The vent will rise. The fan will start at power level 2. The fan will automatically turn off if it is blocked while rising or retracting. When the obstruction is removed, press the On/Off
  • Miele DA 6480 | Operating and Installation manual - Page 11
    system. - Turn off the ventilation system by pressing the 0/1 button. - Disconnect the ventilation system from the power supply, see "Important Safety Instructions". - Leave the ventilation system off for an extended period of time so that any liquid that may have entered can evaporate. Do not open
  • Miele DA 6480 | Operating and Installation manual - Page 12
    Cleaning and Care Before cleaning or servicing the ventilation system, disconnect it from the power supply, see "Important Safety Instructions". Avoid: - cleaning agents containing lye, acids or chlorides, - , a conditioner for stainless steel can be applied. Cleaners are available from Miele. 12
  • Miele DA 6480 | Operating and Installation manual - Page 13
    Cleaning and Care Special instructions for control buttons The controls may change or become discolored if not cleaned regularly, clean soiled areas immediately. ^ Press the On/Off button on the
  • Miele DA 6480 | Operating and Installation manual - Page 14
    Cleaning and Care Cleaning the grease filters ^ By hand: use a scrub brush with a solution of warm water and mild dish soap. Do not use the pure detergent, aggressive all purpose cleaners, oven sprays, abrasive cleaning agents or limescale removers. They could damage the filter. ^ In a dishwasher:
  • Miele DA 6480 | Operating and Installation manual - Page 15
    Repairs In the event of a fault which you cannot easily fix yourself, please contact the Miele Technical Service Department. ^ When contacting the Technical Service Department, please have the model and serial number of your appliance available. These can be found on the data plate located on the
  • Miele DA 6480 | Operating and Installation manual - Page 16
    16
  • Miele DA 6480 | Operating and Installation manual - Page 17
    " before installing this ventilation system. The installation steps are described in the enclosed "Installation Diagram". Leave these instructions with the appliance for the consumer/user. Information is subject to change. Please refer to our website to obtain the most current product specification
  • Miele DA 6480 | Operating and Installation manual - Page 18
    18
  • Miele DA 6480 | Operating and Installation manual - Page 19
    Caring for the environment Disposal of packing material The cardboard box and packing materials protect the appliance during shipping. They have been designed to be biodegradable and recyclable. Please recycle. ,DANGER Ensure that any plastic wrappings, bags, etc., are disposed of safely and kept
  • Miele DA 6480 | Operating and Installation manual - Page 20
    Appliance dimensions 20
  • Miele DA 6480 | Operating and Installation manual - Page 21
    on the rear of the appliance. x = Distance to the rear of the cabinet or wall. Must be a minimum of ½" (13 mm). Exhaust duct connection diameters DA 6480, 6490 with internal blower DAG 500 6" C (150 mm) DA 6480, 6490 with external blower DAG 1000 10" C (254 mm) Appliance dimensions 21
  • Miele DA 6480 | Operating and Installation manual - Page 22
    Appliance dimensions Cabinet dimensions 22
  • Miele DA 6480 | Operating and Installation manual - Page 23
    e Using the DAG 1000 external blower, install exhaust ducting to the rear (vent duct 10" C (254 mm)). If installing the exhaust ducting to the front, appropriate clearances must be maintained in the cabinet. a) Cooktop overhang b) Minimum width of the cooktop: DA 6480: 28" (711 mm) DA 6490: 34" (864
  • Miele DA 6480 | Operating and Installation manual - Page 24
    Appliance dimensions Installation using the DAG 500 internal blower DAG 500 mounted in front of the exhaust system. DAG 500 mounted behind the exhaust system. Note that the blower must be accessible to install the venting ductwork. 24
  • Miele DA 6480 | Operating and Installation manual - Page 25
    Appliance dimensions Installation using the DAG 1000 external blower connection plate Exhaust air ducting to the front. Exhaust air ducting to the rear. Note that the back must be accessible for the installation of the vent duct. 25
  • Miele DA 6480 | Operating and Installation manual - Page 26
    where there are strong drafts, for instance near windows, doors, etc. Before installation, please read the "Appliance dimensions" and "Important safety instructions". Installation preparation ^ Remove the connection plate from the front of the appliance. ^ Remove the side screws at the top of the
  • Miele DA 6480 | Operating and Installation manual - Page 27
    Installation Alternatively, or additionally, the appliance can also be attached underneath the countertop with the angle brackets provided. ^ First, loosely screw the brackets into the sliding nuts in the housing, then push them up under the countertop. ^ Now tighten the brackets on the housing. ^
  • Miele DA 6480 | Operating and Installation manual - Page 28
    at the marked position. ^ Lay the vent housing on the floor on a blanket or other suitable protection in order to mount the DAG 500 blower or DAG 1000 blower adapter. Decide on the venting direction. If the ventilation system is installed in a cabinet, the vent duct can go through the floor, the
  • Miele DA 6480 | Operating and Installation manual - Page 29
    the rear: In this case, the DAG 500 blower box must be modified. Installation ^ Remove the small cover on the rear of the ventilation system. ^ Loosen the two screws holding the blower in the box. ^ Take the blower out of the box. ^ Mount the blower on the front of the ventilation system housing
  • Miele DA 6480 | Operating and Installation manual - Page 30
    Installation ^ Plug the connection cable from the ventilation system into the blower motor. ^ Mount the vent collar on the rear of the ventilation system. ^ Remove the vent collar of the blower box. ^ Close the opening in the blower box with the cover you removed from the rear of the ventilation
  • Miele DA 6480 | Operating and Installation manual - Page 31
    DAG 500 blower box on the rear The blower box can also be installed on the back of the ventilation system: Installation ^ When finished, mount the previously removed cover on the front. ^ Remove the large cover on the rear. Mounting is the same as if installing on the front. ^ Mount the blower on
  • Miele DA 6480 | Operating and Installation manual - Page 32
    cable to enter the ventilation system from below or from the rear. Remove the respective knock-out. ^ If the system is connected to an external blower, remove the knock-out for the control cable. ^ Install a suitable UL listed cable clamp or conduit fitting (not included) in the knock-out. ^ Align
  • Miele DA 6480 | Operating and Installation manual - Page 33
    ^ Connect the appliance to the electric power supply. Observe the "Important safety instructions" and "Electrical connection" warnings. Installation ^ Replace the cover panel and secure it with 2 nuts. ^ Remove the backing from the grease filters. ^ Place the cover panel
  • Miele DA 6480 | Operating and Installation manual - Page 34
    the opposite side of the connection plate. ^ The ventilation system is connected to the external blower by an additional control cable. Please follow the Operating and Installation Instructions for the DAG 1000. The control cable will be connected in the terminal box of the ventilation system (see
  • Miele DA 6480 | Operating and Installation manual - Page 35
    or in attics, crawl spaces or garages. To reduce the risk of fire, only use metal ductwork. Please read and follow the "IMPORTANT SAFETY INSTRUCTIONS" to reduce the risk of personal injury. Follow all local building codes when installing the ventilation system. Exhaust ducting and connections - The
  • Miele DA 6480 | Operating and Installation manual - Page 36
    , garages, etc. where temperature variations exist, it may need to be insulated to reduce condensation. Only for Canada with the DAG 500 Internal blower: If the installation should meet the construction standard "R2000", then installing the enclosed Reducing Collar is required. It reduces the air
  • Miele DA 6480 | Operating and Installation manual - Page 37
    as follows: The ventilation system may only be used with Miele DAG 500 or DAG 1000 blowers. ^ Verify that the voltage, load and circuit rating power supply, please consult a licensed electrician or contact Miele's Technical Service Department. See back cover for contact information. WARNING:
  • Miele DA 6480 | Operating and Installation manual - Page 38
    Operating and Installation Instructions for the DAG 1000. ^ Connect to the power supply as described previously. ^ The external blower will be connected to the additional control cable. ^ Close the terminal box. ^ Turn the power supply back on. Maximum load with interior-mounted DAG 500 vent motor
  • Miele DA 6480 | Operating and Installation manual - Page 39
    39
  • Miele DA 6480 | Operating and Installation manual - Page 40
    Alteration rights reserved / 4011 M.-Nr. 09 045 140 / 02 INFORMATION IS SUBJECT TO CHANGE. PLEASE REFER TO OUR WEBSITE TO OBTAIN THE MOST CURRENT PRODUCT SPECIFICATIONS, TECHNICAL & WARRANTY INFORMATION.
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

Operating and Installation
Instructions
Downdraft Ventilation System
DA 6480, DA 6490
DAG 500, DAG 1000
To prevent accidents
and appliance damage,
read these instructions
before
installation or use.
M.-Nr. 09 045 140
en - US, CA