Miele DA 6480 DA6490

Miele DA 6480 Manual

Miele DA 6480 manual content summary:

  • Miele DA 6480 | DA6490 - Page 1
    Ventilation Hood DA 6490 36" Downdraft Ventilation Hood Page 1 of 7 Location Codes 1 DAG 500 Internal blower - The blower box can be mounted in such a way that the vent collar is aligned to the left, the right, downwards or towards the rear, as desired. 2 Connection plate when using the DAG 1000
  • Miele DA 6480 | DA6490 - Page 2
    Cut-out Dimensions DA 6480 30" Downdraft Ventilation Hood DA 6490 36" Downdraft Ventilation Hood Page 2 of 7 Location Codes A - Cooktop Overhang B - Cooktop Minimum Width DA6480: 28" (711 mm) DA6490: 34" (864 mm) C - Vented rear D - Feed the power cord and control cable when using an
  • Miele DA 6480 | DA6490 - Page 3
    Product and Cut-out Dimensions DA 6480 30" Downdraft Ventilation Hood DA 6490 36" Downdraft Ventilation Hood Page 3 of 7 Exhaust air ducting using the DAG 500 internal blower, installed on the front of the appliance [vent duct 6" ø (150 mm)] A to the left or right B downwards C to the rear If the
  • Miele DA 6480 | DA6490 - Page 4
    Cut-out Dimensions DA 6480 30" Downdraft Ventilation Hood DA 6490 36" Downdraft Ventilation Hood DAG 500 Internal W DAG 500 mounted behind the exhaust system. Note that the blower must be accessible to install the venting ductwork Item 28996319USA - DAG 500 Shipping weight 23 lbs (10.5 kg) Shipping
  • Miele DA 6480 | DA6490 - Page 5
    Product and Cut-out Dimensions DA 6480 30" Downdraft Ventilation Hood DA 6490 36" Downdraft Ventilation Hood DAG 1000 External Blower Installation using the DAG 1000 external blower connection plate Page 5 of 7 Exhaust air ducting to the front. Exhaust air ducting to the rear. Note that the back
  • Miele DA 6480 | DA6490 - Page 6
    Dimensions DA 6480 30" Downdraft Ventilation Hood DA 6490 36" Downdraft Ventilation Hood DAG 1000 External Blower Page 6 of 7 ¾ Conduit Size 10" ø DAG 1000 External Blower exhaust diameter- 10" Ø (254 mm) Item 28996291USA - DAG 1000 Shipping weight 55 lbs (25 kg) Shipping dimensions 36 1/4" (920
  • Miele DA 6480 | DA6490 - Page 7
    Product and Cut-out Dimensions DA 6480 30" Downdraft Ventilation Hood DA 6490 36" Downdraft Ventilation Hood Downdraft Recirculation Kit DUU 2900 2 3 1 DKF 18-1 Charcoal filters included Page 7 of 7 All installations must be done in accordance with local codes. Drawing is not to scale
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7

Product Dimensions
Page 1 of 7
DA 6480 30” Downdraft Ventilation Hood
DA 6480 30 Downdraft Ventilation Hood
DA 6490 36” Downdraft Ventilation Hood
Location Codes
1
DAG 500 Internal blower – The blower box can be mounted in such a way that the
vent collar is aligned to the left, the right, downwards or towards the rear, as desired.
2
Connection plate when using the DAG 1000 external blower. The blower or the
connection plate can also be mounted in the same position on the rear of the
Appliance.
X
= Distance to the rear of the cabinet or wall. Must be a minimum of ½” (13 mm).
Exhaust duct connection diameters
DA 6480, DA 6490 with internal blower
DA 6480, DA 6490 with external blower
DAG 500 Internal Blower - 6” Ø (150 mm)
DAG 1000 External Blower- 10” Ø (254 mm)
Item 28648050USA – DA 6480 Shipping weight
44 lbs (20 kg)
Shipping dimensions 31 5/16” (795 mm) L x 8 1/4” (210 mm) W x 33 1/16” (840 mm) H
Item 28649050USA – DA 6490 Shipping weight
50.7 lbs (23 kg)
Shipping dimensions 37“ (940 mm) L x 8 1/4” (210 mm) W x 33 1/16” (840 mm) H
The hood requires a 120 VAC, 60 Hz, 15 A hard wire connection to the terminal.
All electrical work should be performed by a qualified electrician.
All installations must be done in accordance with local codes.
Drawing is not to scale
Specification Sheets OJS 05152012