NEC NP-PA803UL Recommended Light Output

NEC NP-PA803UL Manual

NEC NP-PA803UL manual content summary:

  • 1

60"
72"
100"
120"
150"
200"
300"
400"
1.1
1.6
3.1
4.5
7
12.4
27.9
49.5
NEC Product
Technology
Category
L102W
DLP
Mobile
909
625
323
222
143
81
36
20
VE281, VE281X, M282X
DLP
Mobile
2545
1750
903
622
400
226
100
57
V302H
DLP
Mobile, Education
2727
1875
968
667
429
242
108
61
V311X, V311W
DLP
Mobile, Education
2818
1938
1000
689
443
250
111
63
M322X, M322W, U321H
DLP
Portable, Education
2909
2000
1032
711
457
258
115
65
M332XS
LCD
Education
3000
2063
1065
733
471
266
118
67
M352WS, UM351W, UM352W
LCD
Education
3182
2188
1129
778
500
282
125
71
UM361X
LCD
Education
3273
2250
1161
800
514
290
129
73
M402X, P401W, M402H
DLP, LCD, DLP
Installation, Education
3636
2500
1290
889
571
323
143
81
P451X, P451W
LCD
Installation, Education
4091
2813
1452
1000
643
363
161
91
P501X
LCD
Installation, Education
4545
3125
1613
1111
714
403
179
101
PA521U
LCD
Installation, Education
4727
3250
1677
1156
743
419
186
105
PA571W
LCD
Installation, Education
5182
3563
1839
1267
814
460
204
115
PX602WL, PX602UL
DLP
Installation, Extended Use/Education
5455
3750
1935
1333
857
484
215
121
PA621X/PA622U
LCD
Installation, Education
5636
3875
2000
1378
886
500
222
125
PA672W
LCD
Installation, Education
6091
4188
2161
1489
957
540
240
135
PX700W2
DLP
Installation/Extended Use
6364
4375
2258
1556
1000
565
251
141
PA722X
LCD
Installation, Education
6545
4500
2323
1600
1029
581
258
145
PX750U2
DLP
Installation/Extended Use
6818
4688
2419
1667
1071
605
269
152
PX800X2
DLP
Installation/Extended Use
7273
5000
2581
1778
1143
645
287
162
PH1000U
3-Chip DLP
Installation/Extended Use
10000
6875
3548
2444
1571
887
394
222
PH1202HL, PH1201QL
3-Chip DLP
Installation/Extended Use
10909
7500
3871
2667
1714
968
430
242
PH1400U
3-Chip DLP
Installation/Extended Use
12727
8750
4516
3111
2000
1129
502
283
Ambient Light
Minimum of 100 lumens per square meter is required for environments with low ambient light.
Low
Minimum of 200 lumens per square meter is required for environments with some ambient light.
Moderate
Minimum of 400 lumens per square meter is required for environments with high ambient light.
High
* - WT610 has a maximum screen size of 100" diagonal
Screen gain of 1.0 is assumed
8000
11000
12000
14000
1LUMEN per square meter is equal to 1 LUX
6000
6200
6700
7000
7200
7500
3600
4000
4500
5000
5200
5700
2800
3000
3100
3200
3300
3500
Screen Diag.
Square Meters
Lumens
Divide lumens (left) by the screen size in square meters (above) to obtain figures below.
1000