Oregon Scientific RGR126 US User Manual

Oregon Scientific RGR126 US Manual

Oregon Scientific RGR126 US manual content summary:

  • Oregon Scientific RGR126 US | User Manual - Page 1
    Model: RGR126 User Manual CONTENTS Introduction 2 Product Overview 2 Front View 2 Back View 3 LCD Display 4 Rain Gauge (PCR122 4 Temperature 11 Outdoor 11 Indoor 11 Reset 11 Precautions 11 Technical Specifications 12 Notices 12 Statement of Responsibility 12 About Oregon Scientific
  • Oregon Scientific RGR126 US | User Manual - Page 2
    EN INTRODUCTION PRODUCT OVERVIEW Congratulations on purchasing the Oregon ScientificTM Wireless Rain Gauge with Indoor / Outdoor Thermometer (RGR126). The rain gauge is equipped with the following functions: FRONT VIEW • Daily and total rainfall display • 9-day rainfall history • Rainfall
  • Oregon Scientific RGR126 US | User Manual - Page 3
    reset the rainfall counter to start again 6. HISTORY: Toggles between rainfall history and daily rainfall 7. : Enables or disables the rainfall alarm 8. REMOVABLE TABLE STAND: For securing the main unit on a flat surface BACK VIEW 1. ANTENNA: Receives radio signal from rain gauge and remote
  • Oregon Scientific RGR126 US | User Manual - Page 4
    , Time / Date 2. Rain Gauge RF Reception Status, Total Rainfall 3. Thermo-sensor RF Reception Status, Outdoor Temp 4. Indoor Temp RAIN GAUGE (PCR122) 1. ANTENNA: Transmits radio signal to main unit 2. BATTERY COMPARTMENT: Accommodates 2 x UM-3 or AAsized batteries 1 2 4 RGR126(R13)-4(final
  • Oregon Scientific RGR126 US | User Manual - Page 5
    EN REMOTE THERMO SENSOR (THN122N) 1. LED Indicator 1 1 2 3 4 1. WALL MOUNT HOLE 2. RESET hole 3. CHANNEL number (1-3) 4. BATTERY COMPARTMENT RGR126(R13)-4(final) 5 5 4/6/05, 5:46 PM
  • Oregon Scientific RGR126 US | User Manual - Page 6
    from a remote unit please repeat gauge. NOTE Every time the battery in the main unit is changed, repeat installation before use. RAIN GAUGE (PCR122) 1. Insert the batteries, matching the polarity (+ and -) as shown in the battery compartment. 2. Mount the rain gauge on a level surface. 6 RGR126
  • Oregon Scientific RGR126 US | User Manual - Page 7
    rain gauge. THERMO SENSOR (THN122N) 1. Insert the batteries, matching the polarity (+ and -) as shown in the battery compartment. RGR126(R13)-4(final) 7 2. Set the channel switch to any channel. The switch is located in the battery compartment. 3. Press RESET on the sensor. 4. Close the remote
  • Oregon Scientific RGR126 US | User Manual - Page 8
    estimated freezing range of below -40°F (-40°C). Wireless ranges can be impacted by a variety of factors reduce the effective range between the sensor and the base station. If the unit's performance fails due to low temperature, and furniture. 8 RGR126(R13)-4(final) 8 4/6/05, 5:46 PM
  • Oregon Scientific RGR126 US | User Manual - Page 9
    fails, check: • The remote rain gauge and thermo sensor are still in place. • The batteries of the main unit, rain gauge, and thermo sensor are still good. Replace them if necessary. • The 6. The order of the settings is hour, minute, year, month and day. RGR126(R13)-4(final) 9 9 4/6/05, 5:46 PM
  • Oregon Scientific RGR126 US | User Manual - Page 10
    the existing commencing date and reset it to start again, rain alarm is on the indicator will not stop flashing unless is pressed or the rain alarm value is changed. To stop the alarm and reminder beep, press any button or change the rainfall alarm value. To deactivate the alarm, press . 10 RGR126
  • Oregon Scientific RGR126 US | User Manual - Page 11
    Centigrade and Fahrenheit display units. RESET This button should only be used user-serviceable parts. • Only use fresh batteries as specified in the user's manual. Do not mix new and old batteries as the old ones may leak. • Always read the user's manual thoroughly before operating the unit. RGR126
  • Oregon Scientific RGR126 US | User Manual - Page 12
    of the product, whether intentional or unintentional. Oregon Scientific will not be responsible for any deviations in the usage of the device from those specified in the user instructions or any approved alternations or repairs of the product. 12 RGR126(R13)-4(final) 12 4/6/05, 5:46 PM
  • Oregon Scientific RGR126 US | User Manual - Page 13
    Oregon Scientific products such as digital cameras; MP3 players; children's electronic learning products and games; projection clocks; health and fitness gear; weather stations Oregon Scientific Customer Care department directly, please visit: www2.oregonscientific.com/service/support Part instructions
  • Oregon Scientific RGR126 US | User Manual - Page 14
    We Name: Address: Telephone No.: Fax No.: Oregon Scientific, Inc. 19861 SW 95th Ave., Tualatin, Oregon 97062 USA 1-800-853-8883 1-503-684-3332 declare that the product Product No.: RGR126 Product Name: Wireless Rain Monitor Manufacturer: IDT Technology Limited Address: Block C, 9/F, Kaiser
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14

EN
1
Wireless Rain Gauge
with Indoor / Outdoor Thermometer
Model: RGR126
User Manual
CONTENTS
Introduction
..............................................................
2
Product Overview
....................................................
2
Front View
..............................................................
2
Back View
..............................................................
3
LCD Display
...........................................................
4
Rain Gauge (PCR122)
...........................................
4
Remote Thermo Sensor (THN122N)
.....................
5
Getting Started
.........................................................
6
Main Unit
................................................................
6
Rain Gauge (PCR122)
...........................................
6
Thermo Sensor (THN122N)
...................................
7
Data Transmission
.................................................
9
Low Battery Warning
...............................................
9
Clock / Calendar Setting
..........................................
9
Set Clock & Calendar
............................................
9
Rainfall
....................................................................
10
Rainfall History
.....................................................
10
Total Rainfall
........................................................
10
Rainfall Alarm
......................................................
10
Temperature
............................................................
11
Outdoor
................................................................
11
Indoor
...................................................................
11
Reset
.......................................................................
11
Precautions
............................................................
11
Technical Specifications
.......................................
12
Notices
....................................................................
12
Statement of Responsibility
.................................
12
About Oregon Scientific
........................................
13
FCC Statement
.......................................................
13
Declaration of Conformity
....................................
14
RGR126(R13)-4(final)
4/6/05, 5:46 PM
1