Panamax MB1000 Addendum for Service

Panamax MB1000 Manual

Panamax MB1000 manual content summary:

  • Panamax MB1000 | Addendum for Service - Page 1
    ADDITIONAL TECHNICAL INFORMATION: Panamax MB1000 is intended to be installed in a dry indoor environment with a maximum ambient temperature of 0 - 40°C (32 - 104°F) and that is free of conductive contaminants. NOTICE TO SERVICE PERSONNEL ONLY: Input SYSTEM FUNCTIONAL BLOCK DIAGRAM EMI Filter
  • 1

ADDITIONAL TECHNICAL INFORMATION:
Panamax MB1000 is intended to be installed in a dry indoor environment with a maximum
ambient temperature of 0 – 40°C (32 – 104°F) and that is free of conductive contaminants.
1690 Corporate Circle, Petaluma, CA 94954
www.panamax.com
707-283-5900
Fax 707-283-5901
When replacing batteries, replace the two batteries with the following:
BB Battery, Part Number
SH7-12
, rated
12V
,
28W
CAUTION:
RISK OF ENERGY HAZARD: 12V, maximum 9 Ampere-hour batteries. Before replacing
batteries, remove conductive jewelry such as chains, wrist watches and rings. High energy
through conductive materials could cause severe burns.
CAUTION:
DO NOT dispose of batteries in a fire.
The batteries may explode.
CAUTION:
DO NOT open or mutilate batteries.
Released material is harmful to the skin and eyes
and may be toxic.
NOTICE TO SERVICE PERSONNEL ONLY:
INS00851 PMX ADDENDUM
Battery
EMI Filter
Surge
Suppressor
AVR
Charger
AC / DC
Inverter
Input
Output
Normal Mode
Battery Mode