Pyle PLTM40 User Manual

Pyle PLTM40 Manual

Pyle PLTM40 manual content summary:

  • Pyle PLTM40 | User Manual - Page 1
    II Q MD, >XV- USB 3 7 7 0. 2 4 6 PL7-11/140 Digital Multimeter Warning READ AND UNDERSTAND THIS MANUAL BEFORE USING THE INSTRUMENT Failure to understand and comply with the warnings and operating instructions can result in serious or fatal injuries and/or property damage. Please read carefully
  • Pyle PLTM40 | User Manual - Page 2
    , BUTTONS AND INPUT JACK ELUCIDATION 4 3. SPECIFICATIONS 5 3.1 GENERAL SPECIFICATIONS 5 3.2 ELECTRICAL SPECIFICATION 5 4. OPERATING INSTRUCTION 7 4.1 POWER-ON 7 4.2 DATA HOLD & CABLE TEST MANUAL SWITCH 8 4.3 BACK LIGHT 8 4.4 PREPARATION FOR MEASUREMENT 8 4.5 MEASURING DC VOLTAGE
  • Pyle PLTM40 | User Manual - Page 3
    4.8 MEASURING AC CURRENT 11 4.9 MEASURING RESISTANCE 12 4.10 TESTING DIODE 13 4.11 TESTING CONTINUITY 13 5. CABLE TESTER INSTRUCTION 14 5.1 SUMMARY 14 5.2 MAIN PERFORMANCE 14 5.3 FAULTY PHENOMENON 15 5.4 OPERATION 15 5.5 FUNCTIONAL DESCRIPTION 16 6. MAINTENANCE 16 6.1 BATTERY
  • Pyle PLTM40 | User Manual - Page 4
    all safety and operating instructions to ensure that the meter is used safely and kept in good operating condition. With proper use and care, the digital meter will give you years of satisfactory service. 1.1 PRELIMINARY 1.1.1 1.1.2 1.1.3 1.1.4 1.1.5 When using the meter, the user must observe
  • Pyle PLTM40 | User Manual - Page 5
    fastened fully. 1.2.13 Please do not store or use meter in areas exposed to direct sunlight, high temperature, humidity or condensation. 1.3 SYMBOLS A Important safety information, refer to the operating manual. g Double insulation (Protection classII) CAT II Overvoltage (installation) category
  • Pyle PLTM40 | User Manual - Page 6
    Logo The battery is not sufficient for proper operation. HOLD/TEST Keep switch and cable test manual. 1.4 MAINTENANCE 1.4.1 1.4.2 1.4.3 1.4.4 Please do not attempt to adjust or repair the meter by removing the rear case while voltage is being applied. A technician who fully understands danger
  • Pyle PLTM40 | User Manual - Page 7
    2.1 NAMES OF COMPONENTS (1) LCD Display (2) Cable test light (3) Back light switch (4) Digital Switch (5) Rotary Switch (6) 20A Jack (7) mA Jack (8) V/O /Hz Jack (9) COM Jack (10) Cable test long-distance Light (11) Removed accessory (12) RJ45, RJ11, RJ12, Jack (13) USB, Jack (14) RJ45, RJ11, RJ12,
  • Pyle PLTM40 | User Manual - Page 8
    Between Terminals And Earth Ground: 1000V DC and 700V AC. 3.1.2 Fuse Protection: F 500mA/250V 3.1.3 Operating Altitude: 2000 meters (7000 ft.) maximum 3.1.4 Display: 38mm LCD 3.1.5 Max. Show Value: 1999 (3 1/2) 3.1.6 Polarity Indication: "-" indicates negative polarity. 3.1.7 Overrange Indication
  • Pyle PLTM40 | User Manual - Page 9
    - Input Impedance: 10MS) - Overload Protection: 200mV range: 250V DC or AC rms, 2V-1000V ranges: 1000V DC or AC rms. - Max. Input Voltage: 1000V DC 3.2.2 AC Voltage Range 2V 20V 200V 750V Resolution 0.001V 0.01V 0.1V 1V Accuracy ± (0.8%, of rdg + 3 digits) ± (1.2%, of rdg + 3 digits) - Input
  • Pyle PLTM40 | User Manual - Page 10
    Display: read approximate forward voltage of diode - Forward DC Current: approx. 1mA - Reversed DC Voltage: approx. 3.0V - Overload Protection: 250V DC or AC rms 4. OPERATING INSTRUCTION 4.1 POWER-ON Press the "ON/OFF" button to turn the meter ON or OFF. 7
  • Pyle PLTM40 | User Manual - Page 11
    data will be hold in display and show " 4.2.2 When you test manual range of net cable, press "HOLD/TEST" and long-range LED, the input voltage or current should be less than specification on the sticker of the meter to protect the inner circuit from damaging. 4.4.3 Select a function and a range
  • Pyle PLTM40 | User Manual - Page 12
    polarity of the red test lead connection will be indicated. NOTE: • At the low voltage range, the meter will show unsteady reading when test leads haven't touched the circuit, it's normal because the meter is very sensitive. When test leads touch the circuit, you can get the true reading. • When
  • Pyle PLTM40 | User Manual - Page 13
    under measurement. 4.6.4 You can get reading from LCD. NOTE: • At the low voltage range, the meter will show unsteady reading when test leads E VA haven't touched the circuit, it's normal because the meter is very sensitive. When test leads touch the circuit, you can get the true reading
  • Pyle PLTM40 | User Manual - Page 14
    the fuse. 20 A's maximum current is 20A, no fuse protection. 4.8 MEASURING AC CURRENT A WARNING Shut down the power of the tested circuit, then connect the meter with the circuit for measurement. Inmunun i'mnnu O 868 A 08 11
  • Pyle PLTM40 | User Manual - Page 15
    4.8.1 Connect the black test lead to the COM jack and the red test lead to the mA jack for a maximum of 200mA current, For a maximum of 20A, move the red lead to the 20A jack. 4.8.2 Set the transform switch at the desired mA or A range position. 4.8.3 Connect test leads in series with the load under
  • Pyle PLTM40 | User Manual - Page 16
    NOTE: • At the manual rangemode, when only the figure "1" is displayed, it indicates overrange situation and the higher range has to be selected. • For measuring resistance above IMO , the meter may take a few seconds to get stable reading. • When the input is not connected, i.e. at open circuit,
  • Pyle PLTM40 | User Manual - Page 17
    figure "1" will be displayed. IuIuI u$I YaVa° 5. CABLE TESTER INSTRUCTION 5.1 SUMMARY This network cable tester is using to scan and judge the continuation property of the double-twisted cable. Both automation and manual are feasible. 5.2 MAIN PERFORMANCE 5.2.1 5.2.2 5.2.3 5.2.4 5.2.5 Test
  • Pyle PLTM40 | User Manual - Page 18
    with the mainframe and removed accessory. (2) Turn the switch on automatic mode. If everything is well, the lights of mainframe and removed will flash synchronism. 5.4.2 MANUAL MODE: (1) Connect the two terminals of cable with the mainframe and removed accessory. (2) Turn the switch on
  • Pyle PLTM40 | User Manual - Page 19
    RJ11 USB 1 2 3 4 5 6 7 8 J  J ,/ J V ,/   V ,/ V ,/  J J J J  J 6. MAINTENANCE 6.1 BATTERY REPLACEMENT A WARNING Before attempting open the battery cover of the meter, be sure that test leads have been disconnected from measurement circuit to avoid electric shock
  • Pyle PLTM40 | User Manual - Page 20
    REPLACEMENT L WARNING Before attempting open the battery cover of the meter, be sure that test leads have been disconnected from measurement circuit (i) Test Leads: Electric Ratings 1000V 10A (2) Battery: 9V 6F22 (3) Operating Manual (6) Yellow holster one piece one piece one piece one piece 17
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

PYLE®
www.PyleAudio.com
nnn
200
1
3
5
7
0
40 40 40 40
40 40
to
40
a
l
NIMBI
2
4
8
8
LIGHT
2
ZIA
200k
2r°.
A—
A
PYLEA
mA
4.444
QOM
20
Ve
200
1000
750
200
a
2
V—
•wx
>XV-
II
Q
MD,
3
7
USB
7
2
4
6
0.
PL7
-
11/140
Digital
Multimeter
Warning
READ
AND
UNDERSTAND
THIS
MANUAL
BEFORE
USING
THE
INSTRUMENT
Failure
to
understand
and
comply
with
the
warnings
and
operating
instructions
can
result
in
serious
or
fatal
injuries
and/or
property
damage.
Please
read
carefully
and
have
a
proper
understanding
of
all
functions
and
operations.