Rheem Hybrid Electric Specifications

Rheem Hybrid Electric Manual

Rheem Hybrid Electric manual content summary:

  • Rheem Hybrid Electric | Specifications - Page 1
    Rheem Hybrid Heat Pump Water Heater Available in 40 and 50 Gallon Models 10-Year Limited Tank and Parts Warranty* • High 2.0 Energy Factor (EF) • 3 Operation modes - Energy Saver (heat pump) - High Demand (heat pump with element backup) - Electric Heat Only (Incoloy elements) • 2-1/2" Non-CFC foam
  • 1

These units are designed to meet
or exceed ANSI (American National
Standards Institute) requirements
and have been tested according to
D.O.E. test procedures and meet
or exceed the energy efficiency
requirements of NAECA, ASHRAE
standard 90, ICC Code and all
state energy efficiency performance
criteria for energy consuming
appliances.
Before purchasing this appliance,
read important energy cost and
efficiency information available
from your supplier.
Rheem Water Heating
• 101 Bell Road, Montgomery, Alabama 36117-4305 • www.rheem.com • www.rheemhpwh.com
Rheem Canada Ltd./Ltée
• 125 Edgeware Road, Unit 1 • Brampton, Ontario L6Y 0P5
PRINTED IN U.S.A
09/10 WP
FORM NO. 102-65 Rev. 5
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
Rheem Hybrid Heat Pump Water Heater
Available in 40 and 50 Gallon Models
±
10-Year Limited Tank and Parts Warranty*
High 2.0 Energy Factor (EF)
3 Operation modes
– Energy Saver (heat pump)
– High Demand (heat pump with element backup)
– Electric Heat Only (Incoloy elements)
2-1/2" Non-CFC foam insulation
Premium resistored anode rod protection,
extends tank life
Exclusive Rheemglas
®
tank lining
Factory installed T&P valve
Brass drain valve
Easy access side connections
Standard 3/4" NPT water inlet, outlet, and condensate
drain connections
21" diameter, fits through access doors
Easily replaces a standard electric water heater
Stainless steel resistor elements
Heat pump operating range 40° F to 120° F
Built in freeze/overheat protection
Easy access, top mounted washable air filter
*See Residential Warranty Certificate for complete warranty
information.
How Hybrid Heat Pump
Water Heaters Work
Rheem air-source heat pump water
heaters work much like a refrigerator
in reverse. The heat pump extracts
the heat from warm air, intensifies the
heat with a compressor, delivers the
heat to the water, and exhausts the
cooler air. Because it uses the warm
ambient air temperature to do most of
the work, it is a very efficient way to
heat water.
Select The Right
Installation Site
For best heat pump operation, the
temperature in the location where the
water heater is to be installed should
average 40 degrees or above.
Choose a warm installation site like
an attic, garage or basement.
Because a heat pump tends to cool
the area where it is located, any type
of air-source heat pump will work
more efficiently in a warm location.
The heat pump will need 1,000 cubic
feet of air space around it (approx.
10x10x10 ft. room).
B
A
T&P
VALVE
HOT
OUTLET
DRAIN
VALVE
COLD
INLET
Energy Factor and Average
Annual Operating Costs based
on 2007 D.O.E. (Department of
Energy) test procedures.
D.O.E. national average fuel
rate electricity 10.65¢/KWH.
8" TOP CLEARANCE
FOR AIR CIRCULATION
3/4" WATER CONNECTIONS
240 VOLT – 1 PH
MAX AMP DRAW – 22 AMPS
User Friendly Integrated
Touch Pad Controls
DESCRIPTION
DIMENSIONS (SHOWN IN INCHES)
ENERGY INFORMATION
FIRST HOUR
RECOVERY IN
HEIGHT
DIAMETER
APPROX.
AVG. ANN.
GAL.
MODEL
RATING
GPH @90° F
UNIT
SHIP
ENERGY
OPER.
CAP.
NUMBER
GPH
RISE
A
B
WT. (LBS)
WT. (LBS)
SAVER
COST
40
HP40RH
56
21
65-1/2
21
190
246
2.0 EF
$234
50
HP50RH
67
21
75-1/2
21
197
267
2.0 EF
$234
25-1/2"