Rheem Hybrid Electric Use and Care Manual

Rheem Hybrid Electric Manual

Rheem Hybrid Electric manual content summary:

  • Rheem Hybrid Electric | Use and Care Manual - Page 1
    Manual With Installation Instructions for the Installer Electric Residential Heat Pump Water Heaters Residential 40 & 50 Gallon The purpose of this manual is twofold: one, to provide the installer with the basic directions and recommendations for the proper installation and adjustment of the water
  • Rheem Hybrid Electric | Use and Care Manual - Page 2
    deal of time and money over the life of your water heater. You'll find many answers to common problems in the Before You Call For Service section. If you review our chart of Troubleshooting Tips first, you may not need to call for service at all. READ THE SAFETY INFORMATION Your safety and the
  • Rheem Hybrid Electric | Use and Care Manual - Page 3
    mixing hot and cold water in branch water lines. Contact a licensed plumber or the local plumbing authority for further information. Hotter Water Cooler  Water CAUTION RISK OF SCALDING INCREASES WITH HOTTER WATER TEMPERATURE SETTING OPERATION MODE HEAT PUMP OFF Review operating manual before
  • Rheem Hybrid Electric | Use and Care Manual - Page 4
    . Should you have problems understanding the instructions in this manual, or have any questions, STOP, and get help from a qualified service technician, or the local electric utility. FOR INSTALLATIONS IN THE STATE OF CALIFORNIA California Law requires that residential water heaters must be braced
  • Rheem Hybrid Electric | Use and Care Manual - Page 5
    consideration the following: Local Installation Regulations This water heater must be installed in accordance with these instructions, local codes, utility codes, utility company requirements or, in the absence of local codes, the latest edition of the National Electrical Code. It is available
  • Rheem Hybrid Electric | Use and Care Manual - Page 6
    the water heater may be easily disconnected for servicing if necessary. The HOT and COLD water connections are clearly marked and are 3/4″ NPT on all models. Install a shut-off valve in the cold water line near the water heater. See page 8 on "To Fill The Water Heater". NOTICE: Do not apply heat to
  • Rheem Hybrid Electric | Use and Care Manual - Page 7
    Supply Heat Trap 6" Min. Union Thermal Expansion Tank (if required) 6" Air Gap Drain Valve A new combination temperature and pressure relief valve, complying with the Standard for Relief Valves and Automatic Gas Shut-Off Devices for Hot Water Supply Systems, ANSI Z21.22/CSA 4.4, is installed
  • Rheem Hybrid Electric | Use and Care Manual - Page 8
    or partially empty tank. To Fill the Water Heater Make certain the drain valve is completely closed. Open the shut-off valve in the cold water supply line. Open each hot water faucet slowly to Electrical Connections ! WARNING! Turn off electric power at the fuse box or service panel before making
  • Rheem Hybrid Electric | Use and Care Manual - Page 9
    manufacturer's instructions included with the kit must be carefully followed. Insulation Blankets Insulation blankets, available to the general public, for external use on electric water heaters are not necessary. The purpose of an insulation blanket is to reduce the standby heat loss encountered
  • Rheem Hybrid Electric | Use and Care Manual - Page 10
    energy efficiency, this water heater has been supplied with two 2-3/8" sections of pipe insulation. Please install the insulation, according to Hot Water Outlet Relief Valve Hot and Cold Pipe Insulation Installation Please install the insulation on the cold water supply inlet and the hot water
  • Rheem Hybrid Electric | Use and Care Manual - Page 11
    voltage agrees with water heater rating plate. ❑ Branch circuit wire and fusing or circuit breaker of proper size. (Minimum 30 amp breaker) ❑ Electrical connections tight and unit properly grounded. ❑ 10 gauge wire. E. Condensate Lines ❑ Condensate lines from heat pump installed correctly
  • Rheem Hybrid Electric | Use and Care Manual - Page 12
    to the water heater. Do not operate the water heater again until it has been thoroughly checked by qualified service personnel. Safety Controls The water heater is equipped with a temperature limiting control (ECO) that is located above the upper heating element in contact with the tank surface. If
  • Rheem Hybrid Electric | Use and Care Manual - Page 13
    " will illuminate to indicate the temperature of the water. To turn the water heater "OFF", press the "OFF" key in the bottom left corner of the control pad. Temporary Electric Heat Only: This is a temporary mode utilized in conjunction with Normal, Hot, and Vacation modes. In this mode compressor
  • Rheem Hybrid Electric | Use and Care Manual - Page 14
    made by service personnel qualified in electric appliance repair. Most electrical appliances, even when new, make some sound when in operation. If the hissing or singing sound level increases excessively, Contact a qualified installer or plumbing contractor to inspect. A water heater's tank can act
  • Rheem Hybrid Electric | Use and Care Manual - Page 15
    in the Operating Instructions. Vacation and Extended Shut-Down If the water heater is to remain idle for an extended period of time, the power and water to the appliance should be turned off to conserve energy and prevent a build-up of dangerous hydrogen gas. The water heater and piping should
  • Rheem Hybrid Electric | Use and Care Manual - Page 16
    the top of the heat pump and the ceiling. ● See the Temperature regulation of the water heater section of this manual ! CAUTION: For your safety DO NOT attempt repair of electrical wiring, thermostats, heating elements or other safety devices. Refer repairs to qualified service personnel. 16
  • Rheem Hybrid Electric | Use and Care Manual - Page 17
    serial number of the water heater from the rating plate. Part description (as noted below) and number of parts desired. ! CAUTION: For your safety DO NOT attempt repair of electrical wiring, heating elements, heat pump or electronic controls. Refer repairs to qualified service personnel. Specify
  • Rheem Hybrid Electric | Use and Care Manual - Page 18
    are intended for qualified service personnel ONLY, and should only be done when necessary. In order to replace the ECO,thermistor or heating element, remove the cavity insert crossbar by following the instructions below: Turn off the power to the water heater. Remove the jacket access panel
  • Rheem Hybrid Electric | Use and Care Manual - Page 19
    Wiring Diagram 19
  • Rheem Hybrid Electric | Use and Care Manual - Page 20
    of the water heater. b. Address where the water heater is located and physical location. c. Name and address of installer and any service agency who performed service on the water heater. d. Date of original installation and dates any service work was performed. e. Details of the problems as you
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

Water Heaters
Electric Residential Heat Pump
The purpose of this manual is twofold:
one, to provide the installer with the basic
directions and recommendations for the proper
installation and adjustment of the water heater;
and two, for the owner–operator, to explain
the features, operation, safety precautions,
maintenance and troubleshooting of the water
heater. This manual also includes a parts list.
It is imperative that all persons who are
expected to install, operate or adjust this
water heater read the instructions carefully
so they may understand how to perform
these operations. If you do not understand
these instructions or any terms within it, seek
professional advice.
Any questions regarding the operation,
maintenance, service or warranty of this
water heater should be directed to the seller
from whom it was purchased. If additional
information is required, refer to the section on
“If you need service.”
Do not destroy this manual. Please read
carefully and keep in a safe place for future
reference.
!
Recognize this symbol as an
indication of Important Safety
Information!
!
California Proposition 65 Warning:
This product contains chemicals known
to the State of California to cause
cancer, birth defects or other
reproductive harm.
Residential 40 & 50 Gallon
92-103234-02-02
AP15121-3 (10/10)
Printed in USA
Use & Care Manual
With Installation Instructions for the Installer
©