  • Ryobi AUN923OPK | User Manual 2 - Page 1
    Guide is not a substitute for reading the operator's manual. To reduce the risk of injury or death, user must read and understand operator's manual before using this product. All page references refer to the operator's manual 18. TROUBLESHOOTING OFF OFF problem continues, contact a qualified service
  • 1

OFF
OFF
15-30 S
991000696
5-1-17 (REV:03)
Install the feet
(see page 11).
WARNING:
This Quick Reference Guide is not a substitute for reading the operator’s manual. To reduce the risk of injury or death, user must read and understand operator’s manual before using this product. All page references refer to
the operator’s manual.
FIRST TIME ASSEMBLY
1
RY907000 QUICK REFERENCE GUIDE
STARTING THE UNIT
USING THE GENERATOR
2
5
Install the wheels
(see page 12).
Add entire bottle of lubricant provided to the
generator
(see page 13).
Add fuel
(see page 14).
1
2
Turn the fuel valve to ON
(see page 15).
Set unit on flat surface so engine is level.
Remove dipstick, wipe clean, put back in hole
(but don’t screw in) and check lubricant level.
This is a 4-cycle engine. Do not mix fuel and
lubricant together.
Mix fuel stabilizer with gasoline according to
manufacturer’s directions prior to filling the
tank.
TOOLS NEEDED
Socket Wrench
4
Raise and secure the handle
(see page 13).
STOPPING THE UNIT
Turn the fuel valve to the OFF position
(see page 15).
1
Connect devices to be powered by generator by following the steps below
(see pages 8-9).
Make sure the generator can supply enough continuous (running) and surge (starting) watts for the items you
will power at the same time. See page 9 for how to calculate total amount of power needed.
Start the generator with nothing connected.
Plug in and turn on the first load, preferably the largest load you have.
Permit the generator output to stabilize (engine runs smoothly and attached device operates properly).
Plug in and turn on the next load.
Again, permit the generator to stabilize.
Repeat previous two steps for each additional load.
IMPORTANT: Never add more loads than the generator capacity. Take special care to consider surge loads in
generator capacity.
(See pages 8-9.)
1
TROUBLESHOOTING
STORING THE UNIT
When preparing to store the generator, allow the unit to cool for 30 minutes, then follow the guidelines listed on
page 18.
1
WARNING:
Do not connect to a building’s electrical
system unless the generator and transfer
switch have been properly installed and
the electrical output has been verified by
a qualified electrician. The connection
must isolate the generator power from
utility power and must comply with all
applicable laws and electrical codes.
IMPORTANT!
Only use OUTSIDE and
far away from windows,
doors, and vents.
NEVER use inside a home
or garage, EVEN IF doors
and windows are open.
Using a generator indoors CAN KILL YOU IN MINUTES.
Generator exhaust contains carbon monoxide. This is a
poison you cannot see or smell.
PROBLEM
POSSIBLE CAUSE
SOLUTION
Engine will not start.
Engine switch is OFF.
No fuel.
Stale gasoline or water in gasoline.
Lubricant level is low.
Fuel valve is OFF.
Spark plug faulty, fouled, or improperly
gapped.
Choke is in RUN position.
Engine stored without treating or draining
gasoline, or refueled with bad gasoline.
Dirty fuel filter.
Turn engine switch to ON.
Fill fuel tank.
Drain entire system and refill with fresh fuel.
Check engine lubrincant level and fill, if
necessary.
Turn fuel valve ON.
Replace spark plug.
Move choke to START position.
Drain fuel and carburetor. Refuel with fresh
gasoline.
Replace fuel filter or contact a qualified service
center.
Engine hard to start.
Water in gasoline.
Weak spark at spark plug.
Drain entire system and refill with fresh fuel.
Replace spark plug or contact a qualified
service center.
Engine lacks power.
Dirty air filter.
Engine stored without treating or draining
gasoline, or refueled with bad gasoline.
Check air filter element. Clean or replace as
needed.
Drain fuel and carburetor. Refuel with fresh
gasoline. If problem continues, contact a
qualified service center.
Electric start feature not
working.
Battery wires are disconnected.
Battery is not charged.
Engine battery charge circuit fuse is blown.
Connect the battery wires.
Charge the battery.
Replace the engine battery charge circuit fuse.
AC receptacle does not work.
Circuit breaker is tripped.
GFCI is tripped.
Item plugged in is defective.
Reset the AC circuit breaker.
Reset the GFCI.
Try a different item.
Generator makes a “spark
knock” or “pinging” noise.
An occasional light “knocking” or “pinging”
under heavy load is not a cause for concern.
However, if the knocking or pinging occurs
under normal load at a steady engine speed,
the problem may be with the brand of gasoline
being used.
Switch to a different brand of gasoline, making
sure that the octane rating is 86 or higher. If
problem continues, contact
a qualified
service
center.
If problem persists after trying the above solutions, contact
customer service or a qualified service center
for assistance.
NOTICE:
As the equipment owner, you are responsible for the performance of the required maintenance listed in the
Maintenance
section. It is recommended that you retain all receipts covering maintenance on your equipment. Neglecting or failing to
perform the required maintenance may increase emissions, decrease fuel efficiency, degrade performance, cause irreversible
engine damage and/or void your warranty.
NOTICE:
Do not use E15 or E85 fuel in this prod-
uct. Only use unleaded gasoline contain-
ing up to 10% ethanol. It is a violation of
federal law and will damage the unit and
void your warranty.
Allow engine to run for 15-30 seconds, then push
choke in to RUN position
(see page 15).
5
Combination Wrench
CHOKE
IN RUN
POSITION
Make the most of your purchase! Go to www.ryobitools.com and
register your new tool online. For questions about operating or
maintaining your product, please call 1-800-860-4050.
FUEL
VALVE ON
4
Slide the lock button down and push the engine
switch to the START position. Engine can also be
started by pulling the recoil starter grip until the
engine runs.
(See page 15)
OFF
3
Pull choke out to START position
(see page 15).
CHOKE IN
START
POSITION
OFF
Phillips Screwdriver
3
Connect the battery
(see page 12).
OFF
LOCK BUTTON
OR PULL RECOIL STARTER
TO START
Turn the engine switch to the OFF position
(see page 15).
2
ENGINE SWITCH
(OFF POSITION)
FUEL
VALVE OFF