Sanyo MPR-1013R Instruction Manual

Sanyo MPR-1013R - Commercial Solutions Lab Manual

Sanyo MPR-1013R manual content summary:

  • Sanyo MPR-1013R | Instruction Manual - Page 1
    INSTRUCTION MANUAL Pharmaceutical Refrigerator MPR-513 MPR-513R MPR-1013 MPR-1013R MPR-513R MPR-1013R
  • Sanyo MPR-1013R | Instruction Manual - Page 2
    if any point in this manual is unclear or if there are any inaccuracies. SANYO Electric Biomedical Co., Ltd. All rights reserved. Printed in Japan. CONTENTS PRECAUTIONS FOR SAFE OPERATION CAUTIONS FOR USAGE ENVIRONMENTAL CONDITIONS REFRIGERATOR COMPONENTS INSTALLATION OPTIONAL COMPONENTS START
  • Sanyo MPR-1013R | Instruction Manual - Page 3
    associated property. Symbol shows;  ˚ this symbol means caution.  this symbol means an action is prohibited.  ˔ this symbol means an instruction must be followed. Be sure to keep this manual in a place accessible to users of this unit. < Label on the unit > This mark is labeled on the cover in
  • Sanyo MPR-1013R | Instruction Manual - Page 4
    the unit is exposed to rain water. Only qualified engineers or service personnel should install the unit. The installation by unqualified personnel may this unit. This may lead to damage to the inner components or electric parts. If this unit is to be used for storing poisons, radioactive material
  • Sanyo MPR-1013R | Instruction Manual - Page 5
    when you request any repair or maintenance for the safety of service personnel. CAUTION Select a level and sturdy floor for installation. exists that an object may fall on it. There are electric components in the upper part of this unit. Current leakage or electric shock may be caused if an object
  • Sanyo MPR-1013R | Instruction Manual - Page 6
    loose. This may cause fire or electric shock. Do not touch any electrical parts such as the power supply plug or any switches with a wet hand. removed for cleaning. This may cause injury due to hot surface. (MPR-1013, MPR-1013R only) Disconnect the power supply plug before moving the unit. Take care
  • Sanyo MPR-1013R | Instruction Manual - Page 7
    minutes. This protects the compressor. 2. This inner cabinet is refrigerated by forced circulation of cooled air inside the chamber. Ensure that the paint or cause it to peel. Plastic and rubber parts can be easily damaged by these materials, especially solvents. When MPR-1013, MPR-1013R only) 6
  • Sanyo MPR-1013R | Instruction Manual - Page 8
    figures show the circuit breaker position. Circuit breaker When the operation of the unit is stopped by this breaker, contact a dealer or a service station after disconnected the power supply plug. WARNING Never disassemble, repair, or modify the unit yourself. Any such work carried out by an
  • Sanyo MPR-1013R | Instruction Manual - Page 9
    REFRIGERATOR COMPONENTS 14 1 7 2 8 14 4 12 9 MPR-513R 1 14 12 4 10 7 15 16 13 10 11 5 17 6 3 2 8 14 10 11 5 9 3 MPR-1013R 15 6 16 13 8
  • Sanyo MPR-1013R | Instruction Manual - Page 10
    Unit cover: The refrigerating units are mounted inside the cover. Remove this cover at the time of cleaning of evaporating tray and filer (filter is attached in MPR-1013 and MPR-1013R only). 16. stopped by this breaker, contact a dealer or a service station after disconnected the power supply plug. 9
  • Sanyo MPR-1013R | Instruction Manual - Page 11
    REFRIGERATOR COMPONENTS Control panel and keypad 7 6 5 1 2 3 4 1. Buzzer stop key (BZ): To silence the audible alarm, press this key. Press it once again to reactivate the alarm. 2.
  • Sanyo MPR-1013R | Instruction Manual - Page 12
    appliances such as gas ranges or stoves. Heat can cause inefficient refrigeration. 4. A location with a sturdy and level floor WARNING Install the fall on it. There are cooling circuits and electric components in the upper part of this unit. Current leakage or electric shock may be caused if an
  • Sanyo MPR-1013R | Instruction Manual - Page 13
    INSTALLATION Installation 1. Remove the packaging materials and tapes Remove all transportation packaging materials and tapes. Open the doors and ventilate the unit. If the outside panels are dirty, clean them with a neutral detergent and wipe it off with a soft cloth washed in clean water. 2.
  • Sanyo MPR-1013R | Instruction Manual - Page 14
    to an instruction manual included with the recorder. The available recorder and a dedicated fixture is as follows: Recorder: Model MTR-G04A (AC 100 to 150 V) Model MTR-G04C (AC 220 to 240 V) Fixture: Model MPR-S7 sensor MTR-G04 MPR-513 MPR-S7 For model MPR-513R, MPR-1013, and MPR-1013R, the
  • Sanyo MPR-1013R | Instruction Manual - Page 15
    . 1. Follow the instruction manual provided with the temperature recorder and attach the recorder to the fixture MPR-S7. 2. Open through the hole after taking out the thermal insulation from it as shown in Fig. 3. MPR-S7 Fig. 2 7. Fix the recorder sensor to the sensor fixture as shown in Fig.
  • Sanyo MPR-1013R | Instruction Manual - Page 16
    is no need for routine defrosting of the unit as this occurs automatically as follows: 1. Cycle defrost To keep the chamber temperature stable, the refrigeration compressor is cycled on and off. During "off" period any frost which has accumulated on the evaporator is melted by energizing a defrost
  • Sanyo MPR-1013R | Instruction Manual - Page 17
    TEMPERATURE SETTING Chamber temperature Table 1 shows the basic procedure for setting the chamber temperature. Perform key operations in the sequence indicated in the table. The example in the table is based on the assumption that the desired temperature is 4oC. Note: The unit is set at the
  • Sanyo MPR-1013R | Instruction Manual - Page 18
    TEMPERATURE SETTING Alarm temperature setting This unit is provided with both high and low temperature alarms. The temperature at which the alarm is activated may be changed. The available set range for high temperature alarm is between +2oC and +14oC and -2oC and -14oC for low temperature alarm
  • Sanyo MPR-1013R | Instruction Manual - Page 19
    or short-circuited. If the defrost sensor 1 is disconnected or short-circuited. If the defrost sensor 2 is disconnected or short-circuited. (MPR-1013,1013R only) When power failure or disconnected the power cord. ALARM lamp is flashed. E01 and 50oC (or -50oC) are displayed alternately. ALARM
  • Sanyo MPR-1013R | Instruction Manual - Page 20
    ALARMS & SAFETY FUNCTIONS Remote alarm terminal WARNING Always disconnect the power supply to the unit prior to connection of alarm equipment to the terminal in order to prevent electric shock or injury. The terminal to which a lead wire of remote alarm is connected is positioned in the box at the
  • Sanyo MPR-1013R | Instruction Manual - Page 21
    electric insulation and cause failure. ɾThe compressor and other mechanical parts are completely sealed. This unit requires absolutely no lubrication. ɾRemove dust from the power supply plug periodically. Cleaning of condenser filter (MPR-1013, 1013R) 1. Remove the screws on the bottom of the unit
  • Sanyo MPR-1013R | Instruction Manual - Page 22
    plate by pulling out the clips towards front. Then take out the evaporating tray as shown in Fig. 2 and Fig. 3. Fig. 1 Clips Fig. 2 For MPR-1013 and MPR-1013R, as shown in Fig. 4, pull out the evaporating tray by lifting up and pulling out towards front. 3. Wash away any accumulated dirt in the
  • Sanyo MPR-1013R | Instruction Manual - Page 23
    starter is located on the right side of top front for MPR-513 and MPR-513R, and center of top front for MPR-1013 and MPR-1013R in the chamber. 1. Turn off the fluorescent lamp and then disconnect the power supply cord of the refrigerator. glow starter 2. Remove the water-proof cover and take out
  • Sanyo MPR-1013R | Instruction Manual - Page 24
     TROUBLESHOOTING  If the unit malfunctions, check out the following before calling for service. If nothing operates even when switched on 1. There is a power failure. 2. The circuit breaker is inactivated. 3. The unit is not connected to the power supply.
  • Sanyo MPR-1013R | Instruction Manual - Page 25
    SPECIFICATIONS  Name Pharmaceutical Refrigerator Model MPR-1013 MPR-1013R MPR-513 MPR-513R External dimensions W1800 x D600 x H1790 (mm) W900 x D600 x H1790 (mm) Internal dimensions Effective capacity Exterior W1700 x D465 x H1300 (mm) W800 x D465 x H1300 (mm) 1037 L
  • Sanyo MPR-1013R | Instruction Manual - Page 26
    V AC 220 V 60 Hz 50 Hz 220 W 205 W AC 230 V 50 Hz 210 W AC 240 V 50 Hz 210 W Model Temperature control range Usable ambient temperature MPR-1013, MPR-1013R +2oC to +14oC -5oC to +35oC Noise level 50 dB (A scale) Maximum pressure 1343 kPa Rated voltage AC 110 V AC 115 V AC 220 V AC 220
  • Sanyo MPR-1013R | Instruction Manual - Page 27
    Contaminated Others: ˘Yes ˘Yes ˘Yes ˘Yes ˘No ˘No ˘No ˘No 3. Instructions for safe repair/maintenance of the unit a) The unit is safe to work on b) Pharmaceutical Refrigerator Model: MPR-513, 513R MPR-1013, 1013R Serial number: Please decontaminate the unit yourself before calling the service
  • Sanyo MPR-1013R | Instruction Manual - Page 28
    7FB6P101277006 (5 April 2005) Recycled paper SANYO Electric Biomedical Co., Ltd. 10-15, Hongo 3-Chome Bunkyoku, Tokyo 113-8434 Japan Printed in Japan
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

MPR-513
MPR-513R
MPR-1013
MPR-1013R
Pharmaceutical Refrigerator
INSTRUCTION MANUAL
MPR-513R
MPR-1013R