Sanyo PLC-WXU300 RS232 Expand

Sanyo PLC-WXU300 - 2500 Lumens Manual

Sanyo PLC-WXU300 manual content summary:

  • Sanyo PLC-WXU300 | RS232 Expand - Page 1
    EXPAND SERIAL COMMAND FUNCTIONAL SPECIFICATIONS PLC-WXU300 Ver. 1.00 SANYO Electric Co., Ltd DS Company Projector Division
  • Sanyo PLC-WXU300 | RS232 Expand - Page 2
    PLC-WXU300 Expand Serial Command Functional Specifications - CONTENTS 1. Overview ...7 2. Serial Interface Specification 7 2.1 Transfer Status Read Command Table 12 6.5 Screen Status Read Command Table 13 6.6 Lamp Status Read Command Table 13 6.7 Sound Status Read Command Table 13 6.8
  • Sanyo PLC-WXU300 | RS232 Expand - Page 3
    PLC-WXU300 Expand Serial Command Functional Specifications 8.4.9 CF_PROGV Command 19 8.4.10 CF_NZRED Command 19 8.7.6 CF_VPOS Command 30 8.7.7 CF_HSCALE Command 30 8.7.8 CF_HPOS Command 31 8.8 Lamp Command 32 8.8.1 CF_LAMPMODE Command 32 8.8.2 CF_LAMPLIFECONTRL Command 32 8.9 Sound Command
  • Sanyo PLC-WXU300 | RS232 Expand - Page 4
    PLC-WXU300 Expand Serial Command Functional Specifications 8.10.1 CF_LANG Command 34 8.10.2 CF_MENUPOSITION Command 34 8.10.3 CF_AUTOSETUPPCADJ Command 34 8.10.4 CF_AUTOSETUPKEYSTONE Command 35 8.10.5 CF_INPUTSEARCH Command 35 8.
  • Sanyo PLC-WXU300 | RS232 Expand - Page 5
    PLC-WXU300 Expand Serial Command Functional Specifications 9.2 Transfer Example 46 9.3 Operation Condition 46 9.4 Image Status Read Command 47 9.4.1 CR_BRIGHT Command 47 9.4.2 CR_CONT Command 47 9.4.3 CR_COLOR Command 47 9.4.4
  • Sanyo PLC-WXU300 | RS232 Expand - Page 6
    PLC-WXU300 Expand Serial Command Functional Specifications 9.8.1 CR_SCREEN Command 57 9.8.2 CR_ KYSTNMODE Command 57 9.8.3 CR_VSCALE Command 57 9.8.4 CR_VPOS Command 57 9.8.5 CR_HSCALE Command 58 9.8.6 CR_HPOS Command 58 9.9 Lamp Status Read Command 59 9.9.1 CR_LAMPREPL Command 59 9.9.2
  • Sanyo PLC-WXU300 | RS232 Expand - Page 7
    PLC-WXU300 Expand Serial Command Functional Specifications 9.11.22 CR_RCODE Command 66 9.11.23 CR_SECURITY Command 66 9.11.24 CR_KEYDIS Command 66 9.11.25 CR_PJLOCKNOW Command 67 9.
  • Sanyo PLC-WXU300 | RS232 Expand - Page 8
    PLC-WXU300. 1.2 Compatible to Firmware Ver. 1.x of the projector. 1.3 Most commands can be used to control projector remotely from be changed in service mode. 2.2 Connection Dedicated serial cable must be used for a connection to a computer and a projector. PC COM 1 Projector Control Port (D-Sub
  • Sanyo PLC-WXU300 | RS232 Expand - Page 9
    PLC-WXU300 Expand Serial Command Functional Specifications 3. Notes for communication 1. Expand Serial power. During this time commands cannot be processed. Do not issue any command. 4. Name Definition 1. Data from a controller to a projector is represented as COMMAND, and data from a projector
  • Sanyo PLC-WXU300 | RS232 Expand - Page 10
    PLC-WXU300 Expand Serial Command Functional Specifications 5. Functional Execution Command Table 5.1 Image Color Temp. value Set /Cancel Progressive Scan Set/Cancel Noise reduction Set Image mode Reset/Store for Image Adjustment 5.2 PC Adjust Control Command Table Execute command CF_FSYNC_%1[CR]
  • Sanyo PLC-WXU300 | RS232 Expand - Page 11
    PLC-WXU300 Set Ceiling function Power ON Start function Set channel of Closed caption Set color of Closed caption Select Remote Control Reception Code Disable RC/Projector keys Input PIN code to release PJ Lock Select Fan mode Select Fan control mode Set time when Filter warning OSD is displayed Reset
  • Sanyo PLC-WXU300 | RS232 Expand - Page 12
    PLC-WXU300 Expand Serial Command Functional Specifications 5.8 Other Command Table Execute command CF_KEYEMU_%1[CR] CF_MENU_%1[CR] CF_POWER_%1[CR] CF_FREEZE _%1[CR] CF_VMUTE _%1[CR] CF_PTIMER _%1[CR] Item Behave the same as corresponding key of Projector / Remote control. Switch ON/OFF of each
  • Sanyo PLC-WXU300 | RS232 Expand - Page 13
    PLC-WXU300 Expand Serial Command Functional Specifications 6. Status Read Command Table 6.1 Image Status Read Command Table Status read command CR_BRIGHT[CR] CR_CONT[CR] CR_COLOR[CR] CR_TINT[CR]
  • Sanyo PLC-WXU300 | RS232 Expand - Page 14
    PLC-WXU300 Expand Serial Command Functional Specifications 6.5 Screen Status Read Command Table Status for Lamp replacement time Get lamp total running time Get corresponding lamp use time Get Lamp Mode status Get lamp lighting status Get projector total running time Get lamp number Get lamp life
  • Sanyo PLC-WXU300 | RS232 Expand - Page 15
    PLC-WXU300 Expand Serial Command Functional Specifications CR_FILH[CR] CR_FILREPL[CR] CR_FILTIMER[CR] Get Filter used time Get the information for Filter replacement time Get time when Filter warning OSD is displayed 6.9 Other Status Read Command Status read command CR_STATUS[CR] CR_SIGNAL[CR]
  • Sanyo PLC-WXU300 | RS232 Expand - Page 16
    PLC-WXU300 Expand Serial Command Functional Specifications 7. Error Code Table Error Code ? 101 Contents -When the received data cannot be decoded -Parameter determination error (digit number error,
  • Sanyo PLC-WXU300 | RS232 Expand - Page 17
    PLC-WXU300 Expand Serial Command Functional Specifications 8. Functional Execution Command 8.1 Format 1. PC issues commands in POWER ON C00: POWER ON (Terminates Countdown) C01: POWER OFF C02: POWER OFF (Terminates Countdown) N/A N/A N/A N/A N/A C00: POWER ON C01: POWER OFF Note:) When the projector
  • Sanyo PLC-WXU300 | RS232 Expand - Page 18
    PLC-WXU300 projector. Therefore, when turning into Standby mode or ALL is OFF, the value returns to original setting. (The value is held in Suspend mode.) This command is available in normal Power Tint value of user control The value set by this command will not be saved to projector. Therefore, when
  • Sanyo PLC-WXU300 | RS232 Expand - Page 19
    PLC-WXU300 Expand Serial Command Functional Specifications 8.4.5 CF_SHARP Command Command "CF_SHARP_%1"[CR] "000~015 Directly select Sharpness setting value %1 "UP Current Sharpness setting value + 1 "DN Current Sharpness setting value - 1 Details Set Sharpness value of user control The
  • Sanyo PLC-WXU300 | RS232 Expand - Page 20
    PLC-WXU300 Expand Serial Command Functional Specifications 8.4.8 CF_COLTEMP Command Command "CF_COLTEMP_%1"[CR] "000" ------ Xlow %1 "001" ------ Low "002" ------ Mid "003" ------ High Details Set Color Temperature. (Available only in the normal Power be saved to projector. Therefore, when
  • Sanyo PLC-WXU300 | RS232 Expand - Page 21
    PLC-WXU300 Expand Serial Command Functional Specifications 8.4.11 CF_IMAGE Command Command "CF_IMAGE_%1"[CR] "DYNAMIC" ------ Dynamic (Fixed value to enable projection with a sharp, powerful Store current Image adjustment to Image 4 Details Reset / store Image adjustment. Parameter "STR1" to
  • Sanyo PLC-WXU300 | RS232 Expand - Page 22
    PLC-WXU300 Expand Serial value returns to original setting. This command is available in normal Power ON status. Acceptable "000"[CR] Response Unacceptable "101"[CR signal The value set by this command will not be saved to projector. Therefore, when turning into Standby mode or ALL is OFF, the value
  • Sanyo PLC-WXU300 | RS232 Expand - Page 23
    PLC-WXU300 Expand Serial Command The value set by this command will not be saved to projector. Therefore, when turning into Standby mode or ALL is OFF, value returns to original setting. This command is available in normal Power ON status. Acceptable "000"[CR] Response Unacceptable "101"[CR]
  • Sanyo PLC-WXU300 | RS232 Expand - Page 24
    PLC-WXU300 Expand Serial Command PC signal The value set by this command will not be saved to projector. Therefore, when turning into Standby mode or ALL is OFF, the value in PC Adjust MENU. This command is available in normal Power ON status. Acceptable "000"[CR] Response Unacceptable "101"[CR
  • Sanyo PLC-WXU300 | RS232 Expand - Page 25
    PLC-WXU300 Expand Serial Command Functional Specifications 8.6 Input Control Command 8.6.1 CF_INPUT Command The same operation as "INPUT" button of the projector and Remote Control. This command is available in normal Power ON status. Projector returns "101" by selecting Computer 2 while Monitor
  • Sanyo PLC-WXU300 | RS232 Expand - Page 26
    PLC-WXU300 Expand Serial Command Functional Specifications Response When Input specified by %1 is inappropriate for selected Input, the projector returns "101" and the command is not executed. This command is available in normal Power ON status. Acceptable "000"[CR] Unacceptable "Error Code"[CR]
  • Sanyo PLC-WXU300 | RS232 Expand - Page 27
    PLC-WXU300 Expand Serial Command Functional Specifications 8.6.7 CF_INPUT5 Command Command "CF_INPUT5 _%1"[CR] %1 "S-VIDEO Select S-video Input Details Response Select S-video input and source specified in %1 at once.. This command is available in normal Power normal Power ON status. Projector
  • Sanyo PLC-WXU300 | RS232 Expand - Page 28
    PLC-WXU300 Expand Serial Command Functional Specifications 8.6.9 CF_SYSTEM Command Command " Input specified by %1 is inappropriate for selected Input, the projector returns "101"[CR] and the command is not executed This command is available in normal Power ON status. Note1) "NTSC" / "NTSC4.43"
  • Sanyo PLC-WXU300 | RS232 Expand - Page 29
    PLC-WXU300 screen. When Input specified by %1 is inappropriate for selected Input, the projector returns "101" [CR] and the command is not executed. "DZOOM UP Zoom When image is expanded or shrunk, reset its value. This command is available in normal Power ON status and when Input is Computer.
  • Sanyo PLC-WXU300 | RS232 Expand - Page 30
    PLC-WXU300 Expand Set Keystone store mode to Reset Details Set Keystone store mode This command is available in normal Power ON status. Acceptable "000 Power ON status. Details Note1) Screen mode is changed into Custom by receiving this command. Note2) When there is no Input, projector returns
  • Sanyo PLC-WXU300 | RS232 Expand - Page 31
    PLC-WXU300 Expand Serial Command Functional Specifications 8.7.6 CF_VPOS Command Command "CF_VPOS_%1"[CR] "015 15 "014 14 " is available in normal Power ON status. Note1) Screen mode is changed into Custom by receiving this command. Note2) When there is no Input, projector returns 101 and the
  • Sanyo PLC-WXU300 | RS232 Expand - Page 32
    PLC-WXU300 Expand Serial Command Functional Specifications 8.7.8 CF_HPOS Command Command "CF_HPOS_%1"[CR] "015 15 "014 14 "002 is available in normal Power ON status. Note1) Screen mode is changed into Custom by receiving this command. Note2) When there is no Input, projector returns 101 and the
  • Sanyo PLC-WXU300 | RS232 Expand - Page 33
    PLC-WXU300 Expand Serial Command Functional Specifications 8.8 Lamp Command 8.8.1 CF_LAMPMODE Command Command "CF_LAMPMODE_%1"[CR] "NORMAL" ------- Set lamp to Normal mode status %1 "ECO Set lamp to 3L mode status "UP Switch Lamp mode forward "DN Switch Lamp mode backward Details Select
  • Sanyo PLC-WXU300 | RS232 Expand - Page 34
    PLC-WXU300 Expand Serial Command Functional Specifications 8.9 Sound Command 8.9.1 CF_VOLUME Command Command like RC operation. The value set by this command is stored in Projector. This command is available in normal Power ON status. Acceptable "000"[CR] Response Unacceptable "Error Code"[CR]
  • Sanyo PLC-WXU300 | RS232 Expand - Page 35
    PLC-WXU300 Expand Serial Command Functional Specifications 8.10 Setting Command 8.10.1 CF_LANG function This command is available in normal Power ON status. Note) It is unable to set Keystone, PC ADJ. and Input search to OFF at once. e.g. If projector receives Auto PC ADJ. OFF command while
  • Sanyo PLC-WXU300 | RS232 Expand - Page 36
    PLC-WXU300 Expand Serial Command Functional Specifications 8.10.4 CF_AUTOSETUPKEYSTONE Command Command "CF_AUTOSETUPKEYSTONE_%1"[CR] "AUTO Set Auto Keystone function to Auto %1 "MANUAL Set Auto Keystone function to Manual "OFF Set Auto Keystone function to OFF Details Set Keystone
  • Sanyo PLC-WXU300 | RS232 Expand - Page 37
    PLC-WXU300 Expand even after ALL is OFF. This command is available in normal Power ON status. Acceptable "000"[CR] Response Unacceptable "Error Code"[CR LOGO LOCK. (LOGO LOCK continues.) Response Projector returns Error Code "101" by receiving USER in %2 when capture has not operated. Acceptable
  • Sanyo PLC-WXU300 | RS232 Expand - Page 38
    PLC-WXU300 Expand Serial Command Functional Specifications 8.10.10 CF_CEIL Command Command "CF_CEIL_%1"[CR] %1 "ON Set Ceiling to ON "OFF Set Ceiling to OFF Details Set/Cancel Ceiling ALL is OFF This command is available in normal Power ON status. Acceptable "000"[CR] Response Unacceptable "
  • Sanyo PLC-WXU300 | RS232 Expand - Page 39
    PLC-WXU300 Expand Serial Command Functional Specifications 8.10.14 CF_TERMINAL Command Command "CF_TERMINAL_%1"[CR] %1 "COMPUTER Set Input mode "MONITOR Set Monitor Out mode Details Set Terminal setup. This command is available in normal Power normal Power ON status. Note) Projector returns
  • Sanyo PLC-WXU300 | RS232 Expand - Page 40
    PLC-WXU300 Expand Serial Command Functional Specifications 8.10.17 CF_PIPPOSITION Command Command Select Subpicture position of Picture in Picture. This command is available in normal Power ON status. Note) Projector returns "101" by receiving this command when Picture in Picture is Off.
  • Sanyo PLC-WXU300 | RS232 Expand - Page 41
    PLC-WXU300 Expand Serial Command Functional Specifications 8.10.20 CF_P-MANETIME Command Command "CF_P-MANETIME_%1"[CR] "01" ~ "30 Directly select setting time by the minute "UP Plus one minute (01 → 02 → → 30 → 01) "DN Minus one minute(30 → 29 → → 01 → 30) Details Set Power Management
  • Sanyo PLC-WXU300 | RS232 Expand - Page 42
    PLC-WXU300 Expand Serial of Remote Control forward "DN Switch Code setting of Remote Control backward Details Select Code of Remote Control Power ON status. Acceptable "000"[CR] Response Unacceptable "Error Code"[CR] 8.10.25 CF_KEYDIS Command Command "CF_KEYDIS_%1"[CR] "NONE RC & Projector
  • Sanyo PLC-WXU300 | RS232 Expand - Page 43
    PLC-WXU300 Expand Serial Command is "On1", it is necessary to transmit this command every time lamp turns on. Acceptable "000"[CR] Unacceptable "Error Code"[CR] 8. even after ALL is OFF. This command is available in normal Power ON status. Acceptable "000"[CR] Response Unacceptable "Error Code"[CR
  • Sanyo PLC-WXU300 | RS232 Expand - Page 44
    PLC-WXU300 Expand Serial Command Functional Specifications 8.10.29 CF_FILTIMER Command Command "CF_FILTIMER_%1"[CR] "100 Set 100 hours "200 Set 200 hours "300 Set 300 hours "OFF No warning display %1 "UP Switch Filter timer forward Off →100 → 200 → 300 → Off "DN Switch Filter timer
  • Sanyo PLC-WXU300 | RS232 Expand - Page 45
    PLC-WXU300 as Select key of Remote control "AUTOPC Execute Auto PC adj Details This command behave the same as corresponding keys of Projector Once Auto PC adj. ON Power ON projector "OFF Power OFF Projector Note1) Countdown can be terminated by sending this command. %1 Note2) Projector
  • Sanyo PLC-WXU300 | RS232 Expand - Page 46
    PLC-WXU300 Expand Serial Command Although projector returns "000", receiving another Freeze command does not release Freeze operation. This command is available in normal Power ON behaves the same as "P-TIMER" key of Remote Control / Projector. Acceptable "000"[CR] Response Unacceptable "Error Code"[
  • Sanyo PLC-WXU300 | RS232 Expand - Page 47
    PLC-WXU300 Expand Serial Command Functional Specifications 9. Status Read Command 9.1 Format 1) PC issues commands in format as below: "CR_Command" [CR] Command: Character Line 2) When projector receives the appropriate command, it returns a character line as the required data "000 "%1 [CR] %1:
  • Sanyo PLC-WXU300 | RS232 Expand - Page 48
    PLC-WXU300 Expand Serial Command Functional Specifications 9.4 Image Status Read Command 9.4.1 CR_BRIGHT Command Command "CR_BRIGHT"[CR] Details Get Brightness value of user control Acceptable "000_ "[CR] Response %a "000"~"063" Unacceptable "Error code"[CR] 9.4.2 CR_CONT Command Command
  • Sanyo PLC-WXU300 | RS232 Expand - Page 49
    PLC-WXU300 Expand Serial Command Functional Specifications 9.4.6 CR_GAMMA Command Command "CR_GAMMA"[CR] Details Get Gamma value of user Command Command "CR_WBAL-R"[CR] Details Get White Balance Red value of user control Acceptable "000_%a"[CR] Response %a "000"~"063" Unacceptable "Error
  • Sanyo PLC-WXU300 | RS232 Expand - Page 50
    PLC-WXU300 Expand Serial Command Functional Specifications 9.4.11 CR_NZRED Command Command "CR_NZRED"[CR] Details Get setting status of Noise Reduction Acceptable "000_%1"[CR] "L1" -------- Noise Reduction for
  • Sanyo PLC-WXU300 | RS232 Expand - Page 51
    PLC-WXU300 Expand Serial Command Functional Specifications 9.5 PC Adjust Status Read Command 9.5.1 CR_FSYNC Command Command "CR_FSYNC"[CR] Details Get Fine Sync value Acceptable "000_%a"[CR] Response %a Unacceptable "
  • Sanyo PLC-WXU300 | RS232 Expand - Page 52
    PLC-WXU300 Expand Serial Command Functional Specifications 9.5.5 CR_V - POS Command Command "CR_V - POS"[CR] Details Get Vertical Position value Acceptable "000_%a"[CR] Response %a Unacceptable "0000"~"nnnn" (nnnn =
  • Sanyo PLC-WXU300 | RS232 Expand - Page 53
    PLC-WXU300 Expand Serial Command Functional Specifications 9.6 Video Status Read Command 9.6.1 CR_SERSYS Command Command "CR_SERSYS"[CR] Details Get currently selected signal Returns auto-detected signal in Auto
  • Sanyo PLC-WXU300 | RS232 Expand - Page 54
    PLC-WXU300 Expand Serial Command Functional Specifications 9.7 Input Status Read Command 9.7.1 CR_INPUT Command Command "CR_INPUT"[CR] Details Get selected INPUT No. Acceptable "000_%1"[CR] Response Request data "1"-"5"
  • Sanyo PLC-WXU300 | RS232 Expand - Page 55
    PLC-WXU300 Expand Serial Command Functional Specifications 9.7.6 CR_SRCINP4 Command Command "CR_SRCINP4" is selected "MODE1" ------- Mode1 is selected "MODE5 Mode5 is selected When there is no signal, projector returns error code"101" [CR] "D XGA1 D-XGA1 is selected Input is HDMI "D WXGA3 D-
  • Sanyo PLC-WXU300 | RS232 Expand - Page 56
    PLC-WXU300 Expand Serial Command Functional Specifications Input is Y,Pb/Cb,Pr / When Input is HDMI "D-XGA D- XGA1is selectable "D-720P" --------- D-720P is selectable When there is no signal, projector returns Error Code "101" -When Input is Y,Pb/Cb,Pr/Cr Returns all the System titles on Menu
  • Sanyo PLC-WXU300 | RS232 Expand - Page 57
    PLC-WXU300 Expand Serial Command Functional Specifications 9.7.10 CR_MODELIST Command Command "CR_MODELIST"[CR] Details Get selectable Mode titles Acceptable "000_%1_%2_..._%x" [CR] Returns Error code "101"
  • Sanyo PLC-WXU300 | RS232 Expand - Page 58
    PLC-WXU300 Expand Serial Custom mode is selected When the screen is set to D.Zoom, projector returns the previous status (NORMAL ) %a Response "NORMAL Normal mode Store mode is "Store" "RST Store mode is "Reset" Unacceptable "Error code"[CR] 9.8.3 CR_VSCALE Command Command "CR_VSCALE
  • Sanyo PLC-WXU300 | RS232 Expand - Page 59
    PLC-WXU300 Expand Serial Command Functional Specifications 9.8.5 CR_HSCALE Command Command "CR_HSCALE"[CR] Details Get setting status of Horizontal Scale Store Mode Acceptable "000_%1"[CR] Response %1 "-32" ~ "032"
  • Sanyo PLC-WXU300 | RS232 Expand - Page 60
    PLC-WXU300 Expand Serial Command Functional Specifications 9.9 Lamp Status Read Command 9.9.1 CR_LAMPREPL Command Command "CR_LAMPREPL"[CR] Details Get information of Lamp Replacement time Acceptable "000_%1"[CR] "1Y Over lamp replacement time "1N Within lamp replacement time Response %1 "1"
  • Sanyo PLC-WXU300 | RS232 Expand - Page 61
    PLC-WXU300 Expand Serial Command Functional Specifications 9.9.5 CR_LAMPMSTS Command Command "CR_LAMPSTS"[CR] Details Get Lighting status of lamp Acceptable "000_%1"[CR] " **** " A number of * should be among 1-4. First character shows how many lamps are incorporated in projector. (1,2 or 4 )
  • Sanyo PLC-WXU300 | RS232 Expand - Page 62
    PLC-WXU300 Expand Serial Command Functional Specifications 9.10 Sound Status Read Command 9.10.1 CR_VOLUME Command Command "CR_VOLUME"[CR] Details Get Volume value of user control Acceptable "000_%a"[CR] Response %a "000"~"063" Unacceptable "Error code"[CR] 9.10.2 CR_MUTE Command Command
  • Sanyo PLC-WXU300 | RS232 Expand - Page 63
    PLC-WXU300 Expand Serial Command Functional Specifications 9.11 Setting Status Read Command 9.11.1 Auto setup Acceptable "000_%a"[CR] "AUTO Auto Keystone is Auto Response %a "MANUAL Auto Keystone is Manual "OFF Auto Keystone is OFF Unacceptable "Error code"[CR] 9.11.4 CR_INPUTSEARCH
  • Sanyo PLC-WXU300 | RS232 Expand - Page 64
    PLC-WXU300 Expand Serial Command Functional Specifications 9.11.5 CR_BACKGND Command Command "CR_BACKGND" [CR] Details Get setting status of Screen for no signal Acceptable "000_%1" [CR] Response "BLUE Blue Back is selected %1 "USER User is selected "BLACK Black Back is selected
  • Sanyo PLC-WXU300 | RS232 Expand - Page 65
    PLC-WXU300 Expand Serial Command Functional Specifications 9.11.10 CR_HDMI SETUP Command Command "CR_HDMI SETUP"[CR] Details Get status of Image mode in HDMI setup Acceptable "000_%1"[
  • Sanyo PLC-WXU300 | RS232 Expand - Page 66
    PLC-WXU300 Expand Serial Command Functional Specifications 9.11.15 CR_PIPPOSITION Command Command ] 9.11.18 CR_P-MANETIME Command Command "CR_P-MANETIME"[CR] Details Get time to start Power Management Acceptable "000_%a"[CR] Response %a "001"~"030 1 minute to 30 minutes Unacceptable "
  • Sanyo PLC-WXU300 | RS232 Expand - Page 67
    PLC-WXU300 Expand 22 CR_RCODE Command Command "CR_RCODE"[CR] Details Get selected Remote Control Code Acceptable "000_%a"[CR] Response %a "001 Projector keys (valid or invalid) Acceptable "000_%a"[CR] "NONE RC / Projector keys are valid Response %a "RC RC keys are invalid "KEY Projector
  • Sanyo PLC-WXU300 | RS232 Expand - Page 68
    PLC-WXU300 Expand Serial Command Functional Specifications 9.11.25 CR_PJLOCKNOW Command Command " PJ Lock status is ON-1 or ON-2 on Menu, and PJ PIN CODE is not entered so that projector is actually locked. Response %1 "FREE PJ Lock is released. PJ Lock status is OFF, or, status
  • Sanyo PLC-WXU300 | RS232 Expand - Page 69
    PLC-WXU300 Expand Serial Command Functional Specifications 9.11.30 CR_FILREPL Command Command " ] 9.11.31 CR_FILTIMER Command Command "CR_FILTIMER" [CR] Details Get setting time which filter warning OSD is displayed Acceptable "000_%1"[CR] "100 100 hours Response %1 "200 200 hours
  • Sanyo PLC-WXU300 | RS232 Expand - Page 70
    PLC-WXU300 Expand Serial Command Functional Specifications 9.12 Other Status Read Command 9.12.1 CR_STATUS Command Command "CR_STATUS"(CR) Details Get status of Projector behavior. This command affects the same as "CR0" of Basic Serial command, but this has an error code. Acceptable "000_%1"[
  • Sanyo PLC-WXU300 | RS232 Expand - Page 71
    PLC-WXU300 Expand Serial Command Functional Specifications 9.12.5 CR_PTIMER Command Command "CR_PTIMER"[CR 9.12.6 CR_TEMPWARN Command Command "CR_TEMPWARN"[CR] Details Get the temperature inside a projector and its condition if it is abnormal temperature or close to abnormal temperature If
  • Sanyo PLC-WXU300 | RS232 Expand - Page 72
    PLC-WXU300 Expand Serial Command Functional Specifications 9.12.7 CR_TEMP Command Command "CR_TEMP"[CR] Details Get current temperature inside a projector high to display Warning) "S" ------- the projectors get abnormal temperature because of heat of Lamp ballast in Standby mode or Powering ON.
  • Sanyo PLC-WXU300 | RS232 Expand - Page 73
    PLC-WXU300 Expand Serial Command Functional Specifications 9.12.8 CR_TEMPFAIL Command Command "CR_TEMPFAIL"[CR] Details Get the temperature inside a projector is safe, all data are represented as "□000S". When the projector is reset, "□000S" is set, and every time abnormal temperature occurs,
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73

EXPAND SERIAL COMMAND
FUNCTIONAL SPECIFICATIONS
PLC-WXU300
Ver. 1.00
SANYO Electric Co., Ltd
DS Company
Projector Division