Sanyo PLC-XL50A RS232 Basic

Sanyo PLC-XL50A - 2000 Lumens Manual

Sanyo PLC-XL50A manual content summary:

  • Sanyo PLC-XL50A | RS232 Basic - Page 1
    BASIC SERIAL COMMAND SPECIFICATIONS PLC-XL50/A Ver. 1.00
  • Sanyo PLC-XL50A | RS232 Basic - Page 2
    POWER OFF Command Quick Power OFF 10 6.7. POWER OFF Command 10 6.8. Computer 1 Command 10 6.9. Computer 2 Command 10 6.10. Video Command 11 6.11. VOLUME + Command 11 6.12. VOLUME - Command 11 6.13. AUDIO MUTE ON Command 11 6.14. AUDIO MUTE OFF Command 11 6.15. VIDEO MUTE ON Command 12 6.16
  • Sanyo PLC-XL50A | RS232 Basic - Page 3
    PLC-XL50 Basic Serial Command Specifications 6.32. BRIGHTNESS - Command 14 6.33. Computer 2 RGB Command 14 6.34. IMAGE (Toggle) Command 15 6.35. ON START Setting Command 15 6.36. ON START Cancel Command 15 6.37. Power Management Ready Command 15 6.38. Power Management OFF Command 15
  • Sanyo PLC-XL50A | RS232 Basic - Page 4
    define projector control commands for PLC-XL50. 1.2. The projector control commands are used to control a projector through can be changed in service mode. 2.2. Connection Dedicated serial cable must be used for connection to a computer and a projector. PC COM 1 Projector Control Port D-Sub 9
  • Sanyo PLC-XL50A | RS232 Basic - Page 5
    PLC-XL50 Basic Serial Command Specifications 3. Notes for Communication 3.1. The projector command is defined as one command/ seconds. 3.5. It takes about 5 seconds for internal initialization after plugging in AC power. During this time, it cannot process commands. Do not issue any command.
  • Sanyo PLC-XL50A | RS232 Basic - Page 6
    PLC-XL50 Basic Serial Command Specifications 4. Functional Execution Command Table Command Item C00 POWER ON POWER OFF C01 Quick Power OFF C02 POWER OFF C03 ――― C04 ――― C05 Computer 1 MC/W/N C06 Computer 2 C07 Video C08 ――― C09 VOLUME + C0A VOLUME - C0B AUDIO MUTE ON C0C
  • Sanyo PLC-XL50A | RS232 Basic - Page 7
    PLC-XL50 Basic Serial Command Specifications Command Item C43 FREEZE ON C44 FREEZE OFF C49 ――― C4A ――― C4E ――― Command CR0 CR1 CR2 CR3 Item Status Read Input Mode Read ――― (Corresponding) Lamp Time Read CR4 CR5 Setting Read ――― CR6 Temp Read "―――" means "No Function". Memo 7/23
  • Sanyo PLC-XL50A | RS232 Basic - Page 8
    PLC-XL50 Basic Serial Command Specifications 6. Functional Execution Command 6.1. Format 6.1.1. PC issues a command in format as below. "C" COMMAND [CR] Command: two characters (See Basic Functional Execution Command Table) 6.1.2. A projector changes received data to decode and returns a result
  • Sanyo PLC-XL50A | RS232 Basic - Page 9
    PLC-XL50 Basic Serial Command Specifications 6.4. Operation Requirements When the projector's status in this below, Functional Execution Commands are limited. Projector Status Standby Mode Processing Countdown Processing Cooling Down Cooling Down due to Abnormal Temperature Abnormal Temperature
  • Sanyo PLC-XL50A | RS232 Basic - Page 10
    PLC-XL50 Basic Serial Command Specifications 6.5. POWER ON Command Command "C00" [CR] Detail Power ON When already Power is ON, nothing is done. When sending this command during processing Countdown, Countdown is terminated. Acceptable Response [ACK] [CR] Unacceptable " "[CR] 6.6. POWER OFF
  • Sanyo PLC-XL50A | RS232 Basic - Page 11
    PLC-XL50 Basic Serial Command Specifications 6.10. Video Command Command "C07" [CR] Detail Select Video Input Notes) When Input search is On1/On2, this command is not executed while the projector returns OK. Acceptable Response [ACK] [CR] Unacceptable " "[CR] 6.11. VOLUME + Command Command
  • Sanyo PLC-XL50A | RS232 Basic - Page 12
    PLC-XL50 Basic Serial Command Specifications 6.15. VIDEO MUTE ON Command Command "C0D"[CR] Detail Video Mute ON. This command works the same as "NO SHOW" button of the remote control for No Show ON, but does not work for No Show OFF. Acceptable Response [ACK] [CR] Unacceptable " "[CR] 6.16.
  • Sanyo PLC-XL50A | RS232 Basic - Page 13
    PLC-XL50 Basic Serial Command Specifications 6.21. Image Cinema Command Command "C13" [CR] Detail Set Image to Cinema mode. Acceptable Response [ACK] [CR] Unacceptable " "[CR] 6.22. Image 1
  • Sanyo PLC-XL50A | RS232 Basic - Page 14
    PLC-XL50 Basic Serial Command Specifications 6. 32. BRIGHTNESS - Command Command "C21" [CR] Detail Brightness of User Control -1. Acceptable Response [ACK] [CR] Unacceptable " "[CR] command is not executed while the projector returns OK, when Input search is On1/On2. Acceptable Response [ACK]
  • Sanyo PLC-XL50A | RS232 Basic - Page 15
    PLC-XL50 Basic Serial Command Specifications 6.34. IMAGE (Toggle) Command Command " "[CR] Detail Switch Image Setting status. This command works the same as "IMAGE" button on the projector CR] Detail Set Power ON Start. This status is stored in EEPROM and retained regardless of Power OFF/ON.
  • Sanyo PLC-XL50A | RS232 Basic - Page 16
    PLC-XL50 This command is not executed while the projector returns OK, when Input search is This command is not executed while the projector returns OK, when Input search is command is not executed while the projector returns OK, when Input search is executed while the projector returns OK, when Input
  • Sanyo PLC-XL50A | RS232 Basic - Page 17
    PLC-XL50 Basic Serial Command Specifications 6.46. Image color board Command Command "C39" [ of On Screen Display Menu to the left This Command differs from the operation of pointer "
  • Sanyo PLC-XL50A | RS232 Basic - Page 18
    PLC-XL50 Basic Serial Command Specifications 6.52. FREEZE ON Command Command "C43" CR] Detail Get into Zoom mode and reduce screen. This command works the same as "ZOOM-" button of Projector. (Zoom function works only when there is no OSD on the screen.) Acceptable Response [ACK] [CR]
  • Sanyo PLC-XL50A | RS232 Basic - Page 19
    PLC-XL50 Basic Serial Command Specifications 6.57. INPUT 1 Scart Command Command "C51" [CR] Detail Select Analog Scart input of Input1. Notes) This command is not executed while the projector returns OK, when Input search is On. Acceptable Response [ACK] [CR] Unacceptable " "[CR] 6.58.
  • Sanyo PLC-XL50A | RS232 Basic - Page 20
    PLC-XL50 Basic Serial Command Specifications 7. Status Read Command 7.1. Format 7.1.1. PC issues commands in format as below; "CR" Command [CR] Command 1 character See Basic Status Read Command Table 7.1.2. When a projector receives the appropriate command, it returns a character line as the
  • Sanyo PLC-XL50A | RS232 Basic - Page 21
    PLC-XL50 Basic Serial Command Specifications 7.3. Status Read Command Command "CR0" [CR] Detail Get the projector status Acceptable "%1" [CR] "00" = Power ON "80" = Standby "40" = Processing Countdown "20" = Processing Cooling Down Response %1 "10" = Power Failure "28" = Processing
  • Sanyo PLC-XL50A | RS232 Basic - Page 22
    PLC-XL50 Basic Serial Command Specifications 7.3.5. "10" [CR] Status : Power Failure When the power supply voltage inside the projector reaches abnormal status, the projector is automatically turned off. The projector returns "10"[CR], which shows it moves to Power OFF status due to power failure.
  • Sanyo PLC-XL50A | RS232 Basic - Page 23
    PLC-XL50 Basic Serial Command Specifications 7.4. Input Mode Read Command Command "CR1" [CR] Detail Get the selected Input. Acceptable "%1" [CR] "1" = Computer1 is selected Response %1 "2" = Computer2 is selected "3" = Video is selected Unacceptable "?" [CR] 7.5. Lamp Time Read Command
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23

BASIC SERIAL COMMAND SPECIFICATIONS
PLC-XL50/A
Ver. 1.00