  • Sanyo PLC-XU300A | RS232 Basic - Page 1
    BASIC SERIAL COMMAND SPECIFICATIONS PLC-XU300 PLC-XU350 Ver.1.00 SANYO Electric Co., Ltd DS Company Projector Division
  • Sanyo PLC-XU300A | RS232 Basic - Page 2
    PLC-XU300/350 Basic Serial Command Specifications CONTENTS 1. Overview ...3 2. Serial Interface Specifications 3 2.1. Transfer Specifications 3 6.4. Operation Requirements 9 6.5. POWER ON Command 10 6.6. POWER OFF Command Quick Power OFF 10 6.7. POWER OFF Command 10 6.8. Computer 1 Command 10
  • Sanyo PLC-XU300A | RS232 Basic - Page 3
    PLC-XU300/350 Basic Serial Command Specifications 6.32. BRIGHTNESS - Command 14 6.33. IMAGE (Toggle) Command 14 6.34. 19 7.2. Transfer Example 19 7.3. Status Read Command 20 7.4. Input Mode Read Command 22 7.5. Lamp Time Read Command 22 7.6. Setting Read Command 22 7.7. Temp Read Command 22
  • Sanyo PLC-XU300A | RS232 Basic - Page 4
    Serial Command Specifications 1. Overview 1.1. These specifications define projector control commands for PLC-XU300/350. 1.2. The projector control commands are used to remotely control a projector through RS-232C from a computer. 2. Serial Interface Specifications 2.1. Transfer Specifications Item
  • Sanyo PLC-XU300A | RS232 Basic - Page 5
    PLC-XU300/350 Basic Serial Command Specifications 3. Notes for Communication 1. The projector control command is defined as one for the interval of 100ms after receiving a response. More than 100ms PC → Projector Projector → PC Command "C" "0" "7" CR ACK CR Next Command Response A few ms
  • Sanyo PLC-XU300A | RS232 Basic - Page 6
    PLC-XU300/350 Basic Serial Command Specifications 4. Functional Execution Command Table Command Item C00 POWER ON C01 POWER OFF Quick Power OFF C02 POWER OFF C03 ――― C04 ――― C05 Computer 1 C06 Computer 2 C07 Video C08 ――― C09 VOLUME + C0A VOLUME - C0B AUDIO MUTE ON C0C
  • Sanyo PLC-XU300A | RS232 Basic - Page 7
    PLC-XU300/350 Basic Serial Command Specifications Command C40 C41 C42 C43 C44 C45 C46 C47 C48 C49 C4A C4B C4C C4D C4E C4F C50 C51 C52 C53 C54 C55 C56 C57
  • Sanyo PLC-XU300A | RS232 Basic - Page 8
    PLC-XU300/350 Basic Serial Command Specifications 5. Status Read Command Table Command CR0 CR1 CR2 Item Status Read Input Mode Read ――― CR3 (Corresponding) Lamp Time Read CR4 CR5 Setting Read ――― CR6 Temp Read CR7 Lamp Mode Read ――― means no function. Memo 7/23
  • Sanyo PLC-XU300A | RS232 Basic - Page 9
    PLC-XU300/350 Basic Serial Command Specifications 6. Functional Execution Command 6.1. Format 6.1.1 PC issues a command in format as below. "C" COMMAND [CR] Command: two characters (See Basic Functional Execution Command Table) A projector changes received data to decode and returns a result after
  • Sanyo PLC-XU300A | RS232 Basic - Page 10
    PLC-XU300/350 Basic Serial Command Specifications 6.4. Operation Requirements When the projector's status is any of below, Functional Execution Commands are limited. Projector Status Standby Mode Countdown in process Cooling Down in process Cooling Down due to Abnormal Temperature Abnormal
  • Sanyo PLC-XU300A | RS232 Basic - Page 11
    PLC-XU300/350 Basic Serial Command Specifications 6.5. POWER ON Command Command "C00" [CR] Detail Power is OFF with ON/STAND-BY button of the projector and remote control, "Power OFF?" is displayed. However, as soon as this command is sent, Quick Power OFF is executed. Acceptable [ACK] [CR]
  • Sanyo PLC-XU300A | RS232 Basic - Page 12
    PLC-XU300/350 Basic Serial Command Specifications 6.10. Video Command Command "C07" [CR] Detail Select Video Input Although projector returns "OK", Input search is not executed with this command while Input search is set to On1 or On2, Acceptable [ACK] [CR] Response Unacceptable " "[CR] 6.
  • Sanyo PLC-XU300A | RS232 Basic - Page 13
    PLC-XU300/350 Basic Serial Command Specifications 6.15. VIDEO MUTE ON Command Command "C0D"[CR] Detail Video Mute ON. This command works the same way as "NO SHOW" button of the remote
  • Sanyo PLC-XU300A | RS232 Basic - Page 14
    PLC-XU300/350 Basic Serial Command Specifications 6.21. Image Cinema Command Command "C13" [CR] Detail Set image to Cinema mode. Acceptable [ACK] [CR] Response Unacceptable " "[CR] 6.22. Image1 Command Command "C14" [CR]
  • Sanyo PLC-XU300A | RS232 Basic - Page 15
    PLC-XU300/350 Basic Serial Command Specifications 6.28. MENU ON Command Command "C1C" [CR] Detail Display On-Screen Display " "[CR] 6.31. BRIGHTNESS + Command Command "C20" [CR] Detail Brightness of User Control +1. Acceptable [ACK] [CR] Response Unacceptable " "[CR] 6.32. BRIGHTNESS -
  • Sanyo PLC-XU300A | RS232 Basic - Page 16
    PLC-XU300/350 Basic Serial Command Specifications 6.34. ON START Setting Command Command "C28" [CR] Detail Enable Power ON Start. This status is stored in EEPROM and retained regardless of Power OFF/
  • Sanyo PLC-XU300A | RS232 Basic - Page 17
    PLC-XU300/350 Basic Serial Command Specifications 6.40. D.ZOOM - Command Command "C31" [CR] Detail CR] 6.41. Video S-Video Command Command "C34" [CR] Detail Select S-Video input. Although projector returns "OK", Input search is not executed with this command while Input search is set to On1
  • Sanyo PLC-XU300A | RS232 Basic - Page 18
    PLC-XU300/350 Basic Serial Command Specifications 6.46. POINTER DOWN Command Command "C3D" [CR] Detail Move down the Pointer of On-Screen Display Menu. This command works the same way as the pointer "▼" of the projector. Acceptable [ACK] [CR] Response Unacceptable " "[CR] 6.47. ENTER Command
  • Sanyo PLC-XU300A | RS232 Basic - Page 19
    PLC-XU300/350 Basic Serial Command Specifications 6.52. Computer 1 Component Command Command "C54" [CR] Detail Select Component input in Computer 1. Although projector returns "OK", Input search is not executed with this command while Input search is set to On1 or On2, Acceptable [ACK] [CR]
  • Sanyo PLC-XU300A | RS232 Basic - Page 20
    PLC-XU300/350 Basic Serial Command Specifications 7. Status Read Command 7.1. Format 7.1.1. PC issues commands in format as below; "CR" Command [CR] Command 1 character See Basic Status Read Command Table 7.1.2. When a projector receives the appropriate command, it returns a character line as the
  • Sanyo PLC-XU300A | RS232 Basic - Page 21
    PLC-XU300/350 Basic Serial Command Specifications 7.3.Status Read Command Command "CR0" [CR] Detail Get the projector processing Countdown is not executed and the status quickly moves to Power ON. "20" [CR] This status automatically moves to Standby after lamp turns off and the fan spin finishes
  • Sanyo PLC-XU300A | RS232 Basic - Page 22
    PLC-XU300/350 Basic Serial Command Specifications moves to Power OFF status due to power failure. in process after turned off due to lamp failure When a projector is turned off because of lamp failure, it automatically starts Cooling Down operation, in which the projector returns "21" [CR]. "81"
  • Sanyo PLC-XU300A | RS232 Basic - Page 23
    PLC-XU300/350 Basic Serial Command Specifications 7.4. Lamp Time Read Command Command "CR3" [CR] Detail Get the total lamp running hours (Not actual lamp the projector. With some temperature sensors installed in the projector, it returned due to hardware %3 problems, the first character becomes
  • Sanyo PLC-XU300A | RS232 Basic - Page 24
    PLC-XU300/350 Basic Serial Command Specifications 7.8.Lamp Mode Read Command Command "CR7" [CR] Detail Get lamp mode status. For 1 lamp projector, get if it is lighting or not. Acceptable "%1" [CR] Response %1 "00" [CR]=Light is out. "01" [CR]=Light is on. Unacceptable " "[CR] 23/23