Sanyo PLC-XU350 Instruction Manual, PLC-XU350 PJ Net Manager Windows
Sanyo PLC-XU350 - XGA LCD Projector Manual
UPC - 086483073823
View all Sanyo PLC-XU350 manuals
Add to My Manuals
Save this manual to your list of manuals |
Sanyo PLC-XU350 manual content summary:
- Sanyo PLC-XU350 | Instruction Manual, PLC-XU350 PJ Net Manager Windows - Page 1
non-Mac-compliant. Read this manual thoroughly to operate the PJ Network Manager software. First, read the owner's manual of the projector to understand the basic operation of the projector and the safety instructions. The safety instructions in the owner's manuals should be followed strictly. SNMP - Sanyo PLC-XU350 | Instruction Manual, PLC-XU350 PJ Net Manager Windows - Page 2
for targets...16 Setting up default setting...17 Customizing the status list...19 Viewing the alert information...22 Viewing the event log...23 Description of Event, Type, Warning column, Warning value 24 About event treatment...26 Viewing the command history...27 Storing the management file...28 - Sanyo PLC-XU350 | Instruction Manual, PLC-XU350 PJ Net Manager Windows - Page 3
software for the network equipment which supports the private MIB (Management Information Base). By installing the PJ Network Manager to the computer, you can monitor the equipment simply such as the projector , it is the protocol to monitor and control the equipment connected to the network. SNMP - Sanyo PLC-XU350 | Instruction Manual, PLC-XU350 PJ Net Manager Windows - Page 4
space Screen resolution LAN SVGA (16 or higher for Windows Vista XGA True color or more manual This manual does not provide the description of basic operation and functions for computer, web browser, projector and network. For instructions about each piece of equipment or application software - Sanyo PLC-XU350 | Instruction Manual, PLC-XU350 PJ Net Manager Windows - Page 5
Chapter 2 2 Set up PJ NETWORK MANAGER OWNER'S MANUAL - Sanyo PLC-XU350 | Instruction Manual, PLC-XU350 PJ Net Manager Windows - Page 6
installing and then follow the installation wizards. As the "Software License Agreement" will appear, read contents carefully and click to proceed with installing. Note: To install the software into the computer with Windows 2000, Windows XP or Manager software from your computer, perform it with "Add - Sanyo PLC-XU350 | Instruction Manual, PLC-XU350 PJ Net Manager Windows - Page 7
Chapter 3 3 Basic Operation PJ NETWORK MANAGER OWNER'S MANUAL - Sanyo PLC-XU350 | Instruction Manual, PLC-XU350 PJ Net Manager Windows - Page 8
Status list * With double clicking the target name, the web browser is launching and displays login window of the target.(+p.31) Items Description Menu Executes a command with menu selection Tool bar Executes a command assigned to a button. Target Network equipment for monitoring. Status bar - Sanyo PLC-XU350 | Instruction Manual, PLC-XU350 PJ Net Manager Windows - Page 9
on the status list. Font setting Sets up display font type and size on the status list. Display Update Updates the information on the tool bar on or off. Help Version information Displays version of software. What's Target Target indicates the network equipment which provides an SNMP agent - Sanyo PLC-XU350 | Instruction Manual, PLC-XU350 PJ Net Manager Windows - Page 10
select "Tool bar" from "Display" menu. Icon display for the target Displays icon according to the target condition. Icon Flat display type Projector type Condition Normal Abnormal condition (One of the abnormalities, Alert, Trap or System error is happening on the target.) Connection error (Target - Sanyo PLC-XU350 | Instruction Manual, PLC-XU350 PJ Net Manager Windows - Page 11
target 1 Select Target Addition from Target menu. The target information registering window appears. Items Description Name Enter a management name of the target equipment. IP address Enter IP address of can be used for target name and community. PJ NETWORK MANAGER 11 OWNER'S MANUAL - Sanyo PLC-XU350 | Instruction Manual, PLC-XU350 PJ Net Manager Windows - Page 12
equipment. 1 S elect a target on the status list with right click. 0 When setting multiple targets together, select targets with pressing "Shift" or "Control" key. 2 Select Warning value setting on the popup menu. The setting window will appear as the right figure. 3 Check Warning time check - Sanyo PLC-XU350 | Instruction Manual, PLC-XU350 PJ Net Manager Windows - Page 13
equipment. Projector has items such as "When PJ lamp is off", "When the life span of lamp is reached", "When internal PJ power circuit is failed" etc. For further trap information, refer to SNMP trap information in the separated network owner's manual - Sanyo PLC-XU350 | Instruction Manual, PLC-XU350 PJ Net Manager Windows - Page 14
from Target menu, the dialog box will appear as the below figure. 2 Select a group, and then click OK button. 0 " ---" will not set the group. 0 The projectors setting different network passwords cannot be set to the same group. It is necessary for the - Sanyo PLC-XU350 | Instruction Manual, PLC-XU350 PJ Net Manager Windows - Page 15
all the targets of the same group. 0The commands also work for the target which is not set to a group. PJ NETWORK MANAGER 15 OWNER'S MANUAL - Sanyo PLC-XU350 | Instruction Manual, PLC-XU350 PJ Net Manager Windows - Page 16
Description Power ON/OFF Sets up the Power ON or Power OFF. Input,Source Sets up the Input and Source. Selects Input and Source. Screen Sets up the screen size the image. Lamp control Sets up the Lamp control. Changes brightness of the screen. Fan control Sets up the Fan control. Chooses the - Sanyo PLC-XU350 | Instruction Manual, PLC-XU350 PJ Net Manager Windows - Page 17
information or E-mail information tab for each setting. Monitoring information Monitoring information Items Description Monitoring interval Sets up the interval of the polling in minute unit. (1 to Sound warning alarm p Send e-mail p Display warning dialog PJ NETWORK MANAGER 17 OWNER'S MANUAL - Sanyo PLC-XU350 | Instruction Manual, PLC-XU350 PJ Net Manager Windows - Page 18
Chapter 3 Basic Operation E-mail information E-mail information Items Description SMTP server Sets up the IP address of SMTP mail server or server host name. Administrator's mail address Sets up the e-mail address of administrator - Sanyo PLC-XU350 | Instruction Manual, PLC-XU350 PJ Net Manager Windows - Page 19
column width Column Description *Target name Name , Power failure, lamp failure, etc.) Replace) *Lamp4 status Status of Lamp4 (Off, On, Error, Replace) *Lamp1 time Used time of Lamp1 *Lamp2 time Used time of Lamp2 *Lamp3 time Used time of Lamp3 *Lamp4 time Used time of Lamp4 *Filter - Sanyo PLC-XU350 | Instruction Manual, PLC-XU350 PJ Net Manager Windows - Page 20
Description *Error info Error information (Not available for the projector Information of the input source (RGB, VIDEO, S-VIDEO, NETWORK, etc.) Network status Condition of Lamp mode Displays lamp mode (1: 1-lamp mode, 2: 2-lamp mode, 4: 4-lamp mode, etc.) Lamp control Displays lamp control - Sanyo PLC-XU350 | Instruction Manual, PLC-XU350 PJ Net Manager Windows - Page 21
to change column width Changing font Select Font setting from System menu. The font setup window will appear. Select your desired type face, style and size on the window. 0 Customized font property is applied to all the windows of the setting. PJ NETWORK MANAGER 21 OWNER - Sanyo PLC-XU350 | Instruction Manual, PLC-XU350 PJ Net Manager Windows - Page 22
Chapter 3 Basic Operation Viewing the alert information 1 Click button on the tool bar. The alert display window appears and the alert informa- tion of all the targets which are having an alert is listed on this window as the below. 2 To export the alert information as text file (CSV file), click - Sanyo PLC-XU350 | Instruction Manual, PLC-XU350 PJ Net Manager Windows - Page 23
button. On the confirmation dialog, click Yes to execute deletion. Event log information items Items Description Accrual date.......... Accrual date of the event Target name......... Name of the network equipment IP drop the column. Column cannot be deleted. PJ NETWORK MANAGER 23 OWNER'S MANUAL - Sanyo PLC-XU350 | Instruction Manual, PLC-XU350 PJ Net Manager Windows - Page 24
Replace Power status Normal(Standby) Normal(OnCoolingDown) PowerFailure Power management Inside Temperature status (A to C) Abnormal External Temperature status Input status SignalIsInterrupted Lamp time (1-4) (lamp time) Filter time (filter time) n/a n/a *1 Error n/a *1 Description - Sanyo PLC-XU350 | Instruction Manual, PLC-XU350 PJ Net Manager Windows - Page 25
Lamp status ON * Failure Replace Lamp time Filter time (Auto play error) (lamp time) (filter time) Error Description Projector has been disconnected from the network Projector file. 0 This Warning column is not available for some projector's model types. PJ NETWORK MANAGER 25 OWNER'S MANUAL - Sanyo PLC-XU350 | Instruction Manual, PLC-XU350 PJ Net Manager Windows - Page 26
item "Viewing the event log" (+p.23). 0 The setting of event treatment, refer to item "Setting up default setting" (+p.17). Notes on using Windows XP Service Pack 2 (SP2) / Windows Vista Windows Firewall is turned on by default in Windows XP SP2 and Windows Vista. Due to this Windows Firewall, the - Sanyo PLC-XU350 | Instruction Manual, PLC-XU350 PJ Net Manager Windows - Page 27
Delete button. On the confirmation dialog box, click Yes button to execute deletion. Command history Items Description Executed date/time..... Exrcuted date and time of the command Target name......... Name of the network deleted and the latest event is added. PJ NETWORK MANAGER 27 OWNER'S MANUAL - Sanyo PLC-XU350 | Instruction Manual, PLC-XU350 PJ Net Manager Windows - Page 28
to the registry of your computer. So the setting condition is memorized even after quitting the application. Items Description Status window information Display position and size of the status list window Status list information Display status column, column width and column order Event log - Sanyo PLC-XU350 | Instruction Manual, PLC-XU350 PJ Net Manager Windows - Page 29
correcting the defined file. 3 Click OK button to execute the registration. 0 Target batch registration is not available during Target monitoring. PJ NETWORK MANAGER 29 OWNER'S MANUAL - Sanyo PLC-XU350 | Instruction Manual, PLC-XU350 PJ Net Manager Windows - Page 30
of the defined file The defined file is a CSV data file created by the spreadsheet application and is defined as follows; Column Description (example) Target name.......... Name of target equipment (Proj_01, Proj_03, PDP_01, etc.) IP address IP address (192.168.0.1, etc.) Community Name of SNMP - Sanyo PLC-XU350 | Instruction Manual, PLC-XU350 PJ Net Manager Windows - Page 31
web browser and displays the login window of the target equipment. You can control and set up the projector remotely by using the web browser. For the further information of instruction, see the separated network owner's manual. Login by double clicking 0 A n example of the login page. PJ NETWORK - Sanyo PLC-XU350 | Instruction Manual, PLC-XU350 PJ Net Manager Windows - Page 32
PM-KF5AC PJ NETWORK MANAGER OWNER'S MANUAL FOR WINDOWS SANYO Electric Co., Ltd.
PJ Network Manager for Windows
SNMP Manager Software
This is the manual for the PJ Network Manager software.
This software is Windows-compliant, but non-Mac-compliant.
Read this manual thoroughly to operate the PJ Network Manager software.
First, read the owner's manual of the projector to understand the basic oper-
ation of the projector and the safety instructions.
The safety instructions in the owner's manuals should be followed strictly.
Owner's Manual