Sanyo PLC-XW250 RS232 Basic

Sanyo PLC-XW250 - 2600 Lumens Manual

Sanyo PLC-XW250 manual content summary:

  • Sanyo PLC-XW250 | RS232 Basic - Page 1
    BASIC SERIAL COMMAND SPECIFICATIONS PLC-XW200 PLC-XW250 Ver.1.00 SANYO Electric Co., Ltd DS Company Projector Division
  • Sanyo PLC-XW250 | RS232 Basic - Page 2
    PLC-XW200/250 Basic Serial Command Specifications CONTENTS 1. Overview ...3 2. Serial Interface Specifications 3 2.1. Transfer Specifications POWER ON Command 10 6.6. POWER OFF Command Quick Power OFF 10 6.7. POWER 19. Image Standard Command 12 6.20. Image Real Command 12 6.21. Image Cinema
  • Sanyo PLC-XW250 | RS232 Basic - Page 3
    PLC-XW200/250 Basic Serial Command Specifications 6.32. BRIGHTNESS - Command 14 6.33. IMAGE (Toggle) Command 14 6.34. ON START Setting Command 15 6.35. ON START Cancel Command 15 6.36. Power Management Ready Command 15 6.37. Power Management OFF Command 15 6.38. Power Lamp Time Read Command
  • Sanyo PLC-XW250 | RS232 Basic - Page 4
    PLC-XW200/250 Basic Serial Command Specifications 1. Overview 1.1. These specifications define projector control commands for PLC-XW200/250. 1.2. The projector control commands are used to remotely control a projector through RS-232C from a computer. 2. Serial Interface Specifications 2.1. Transfer
  • Sanyo PLC-XW250 | RS232 Basic - Page 5
    PLC-XW200/250 Basic Serial Command Specifications 3. Notes for Communication 1. The projector control command is defined as one seconds. 5. It takes about 5 seconds for internal initialization after plugging in AC power. During this time, it cannot process commands. Do not issue any command.
  • Sanyo PLC-XW250 | RS232 Basic - Page 6
    PLC-XW200/250 Basic Serial Command Specifications 4. Functional Execution Command Table Command Item C00 POWER ON C01 POWER OFF Quick Power OFF C02 POWER 16 9 C11 Image Standard C12 Image Real C13 Image Cinema C14 Image 1 C15 Image 2 C16 Image 3 C17 Image 4 C18 Blackboard
  • Sanyo PLC-XW250 | RS232 Basic - Page 7
    PLC-XW200/250 Basic Serial Command Specifications Command C40 C41 C42 C43 C44 C45 C46 C47 C48 C49 C4A C4B C4C C4D C4E C4F C50 C51 C52 C53 C54 C55 C56 C57
  • Sanyo PLC-XW250 | RS232 Basic - Page 8
    PLC-XW200/250 Basic Serial Command Specifications 5. Status Read Command Table Command CR0 CR1 CR2 Item Status Read Input Mode Read ――― CR3 (Corresponding) Lamp Time Read CR4 CR5 Setting Read ――― CR6 Temp Read CR7 Lamp Mode Read ――― means no function. Memo 7/22
  • Sanyo PLC-XW250 | RS232 Basic - Page 9
    PLC-XW200/250 Basic Serial Command Specifications 6. Functional Execution Command 6.1. Format 6.1.1 PC issues a command in format as below. "C" COMMAND [CR] Command: two characters (See Basic Functional Execution Command Table) A projector same as that of the remote control; 6.2.1. System: issues
  • Sanyo PLC-XW250 | RS232 Basic - Page 10
    PLC-XW200/250 Basic Serial Command Specifications 6.4. Operation Requirements 1) When the projector's status is any of below, Functional Execution Commands are limited. Projector Status Standby Mode Countdown in process Cooling Down in process Cooling Down due to Abnormal Temperature Abnormal
  • Sanyo PLC-XW250 | RS232 Basic - Page 11
    is terminated. Acceptable [ACK] [CR] Response Unacceptable " "[CR] 6.6. POWER OFF Command Quick Power OFF Command "C01" [CR] Detail Power OFF (Standby) When Power is OFF with ON/STAND-BY button of the projector and remote control, "Power OFF?" is displayed. However, as soon as this command is
  • Sanyo PLC-XW250 | RS232 Basic - Page 12
    PLC-XW200/250 Basic Serial Command Specifications 6.10. Video Command Command "C07" [CR] Detail Select Video Input Although projector returns " Sound Mute ON. This command works the same way as "MUTE" button of the remote control for Mute ON, but does not work for Mute OFF. Acceptable [ACK] [
  • Sanyo PLC-XW250 | RS232 Basic - Page 13
    PLC-XW200/250 Basic Serial Command Specifications 6.15. VIDEO MUTE ON Command Command "C0D"[CR] Detail Video Mute ON. This command works the same way as "NO SHOW" button of the remote control for No Show ON, but does not work for No Show OFF. Acceptable [ACK] [CR] Response Unacceptable " "[CR]
  • Sanyo PLC-XW250 | RS232 Basic - Page 14
    PLC-XW200/250 Basic Serial Command Specifications 6.21. Image Cinema Command Command "C13" [CR] Detail Set image to Cinema mode. Acceptable [ACK] [CR] Response Unacceptable " "[CR] 6.22. Image1 Command Command "C14" [CR] Detail Set image to Image1 mode. Acceptable [ACK] [CR] Response
  • Sanyo PLC-XW250 | RS232 Basic - Page 15
    PLC-XW200/250 Basic Serial Command Specifications 6.28. MENU ON Command User Control -1. Acceptable [ACK] [CR] Response Unacceptable " "[CR] 6.33. IMAGE (Toggle) Command Command "C27"[CR] Detail Switch Image Setting status. This command works the same way as "IMAGE" button of the remote
  • Sanyo PLC-XW250 | RS232 Basic - Page 16
    EEPROM and retained regardless of Power OFF/ON. Acceptable [ACK] [CR] Response Unacceptable " "[CR] 6.39. D.ZOOM + Command Command "C30" [CR] Detail Enter Digital Zoom mode and expand image size. This command works the same way as "D.ZOOM ▲" button of the remote control. Acceptable [ACK] [CR
  • Sanyo PLC-XW250 | RS232 Basic - Page 17
    PLC-XW200/250 Basic Serial Command Specifications 6.40. D.ZOOM - Command Command "C31" [CR] Detail Enter Digital Zoom mode and reduce image size. This command works the same as "D.ZOOM ▼" button of the remote from the pointer "
  • Sanyo PLC-XW250 | RS232 Basic - Page 18
    PLC-XW200/250 Basic Serial Command Specifications 6.46. POINTER DOWN Command Command "C3D" [CR] Detail Move down the Pointer of On-Screen Display Menu. This command works the same way as the pointer "▼" of the projector image. This command works the same way as "FREEZE" button of the remote
  • Sanyo PLC-XW250 | RS232 Basic - Page 19
    PLC-XW200/250 Basic Serial Command Specifications 6.52. Computer 1 Component Command Command "C54" [CR] Detail Select Component input in Computer 1. Although projector "P-TIMER" button of the remote control. Acceptable [ACK] [CR distortion by reducing upper part of image. Acceptable [ACK] [CR]
  • Sanyo PLC-XW250 | RS232 Basic - Page 20
    PLC-XW200/250 Basic Serial Command Specifications 7. Status Read Command 7.1. Format 7.1.1. PC issues commands in format as below; "CR" Command [CR] Command 1 character See Basic Status Read Command Table 7.1.2. When a projector receives the appropriate command, it returns a character line as the
  • Sanyo PLC-XW250 | RS232 Basic - Page 21
    down the lamps and other optical parts and is quite important for projector's reliability. During this time, Functional Execution Commands are invalid. "10" [CR] Status: Power Failure When the power supply voltage inside the projector reaches abnormal status, the projector is automatically turned
  • Sanyo PLC-XW250 | RS232 Basic - Page 22
    Save This shows that it moves to Power Save status by Power management function in Setting menu. "21" [CR] Status: Cooling Down in process after turned off due to lamp failure When a projector is turned off because of lamp failure, it automatically starts Cooling Down operation, in which the
  • Sanyo PLC-XW250 | RS232 Basic - Page 23
    PLC-XW200/250 Basic Serial Command Specifications to hardware %3 problems, the first character Lamp Mode Read Command Command "CR7" [CR] Detail Get lamp mode status. For 1 lamp projector, get if it is lighting or not. Acceptable "%1" [CR] Response %1 "00" [CR]=Light is out. "01" [CR]=Light