Sanyo PLC-XW250 RS232 Expand

Sanyo PLC-XW250 - 2600 Lumens Manual

Sanyo PLC-XW250 manual content summary:

  • Sanyo PLC-XW250 | RS232 Expand - Page 1
    EXPAND SERIAL COMMAND FUNCTIONAL SPECIFICATIONS PLC-XW200 PLC-XW250 Ver. 1.01 SANYO Electric Co., Ltd DS Company Projector Division
  • Sanyo PLC-XW250 | RS232 Expand - Page 2
    PLC-XW200/250 Expand Serial Command Functional Specifications - CONTENTS 1. Overview ...7 2. Serial Interface Specification 7 2.1 Transfer Specification 7 2.2 Connection...7 3. Notes for communication 8 4. Name Definition ...8 5. Functional Execution Command Table 9 5.1 Image Command Table 9
  • Sanyo PLC-XW250 | RS232 Expand - Page 3
    PLC-XW200/250 Expand Serial Command Functional Specifications 8.4.9 CF_PROGV Command 17 8.4.10 CF_NZRED Command 17 8.4.11 CF_IMAGE Command CF_VPOS Command 26 8.7.7 CF_HSCALE Command 27 8.7.8 CF_HPOS Command 27 8.8 Lamp Command 28 8.8.1 CF_LAMPH Command 28 8.8.2 CF_LAMPMODE Command 28 8.8.3
  • Sanyo PLC-XW250 | RS232 Expand - Page 4
    PLC-XW200/250 Expand Serial Command Functional Specifications 8.10.2 CF_MENUPOSITION Command 30 8.10.3 CF_INPUTSEARCH Command 40 9.1 Format ...40 9.2 Transfer Example 40 9.3 Operation Condition 40 9.4 Image Status Read Command 40 9.4.1 CR_BRIGHT Command 40 9.4.2 CR_CONT Command 40 9.4.3
  • Sanyo PLC-XW250 | RS232 Expand - Page 5
    PLC-XW200/250 Expand Serial Command Functional Specifications 9.4.4 CR_TINT Command 41 9.4.5 CR_SHARP Command 41 9.4.6 CR_GAMMA Command 41 9.4.7 CR_WBAL - R Command 50 9.8.5 CR_HSCALE Command 50 9.8.6 CR_HPOS Command 51 9.9 Lamp Status Read Command 52 9.9.1 CR_LAMPREPL Command 52 4 / 64
  • Sanyo PLC-XW250 | RS232 Expand - Page 6
    PLC-XW200/250 Expand Serial Command Functional Specifications 9.9.2 CR_LAMPH Command 52 9.9.3 CR_LAMPCORRESPH Command 52 9.9.4 CR_LAMPMODE Command 52 9.9.5 CR_LAMPMSTS Command 53 9.9.6 CR_PROJH Command 53 9.9.7 CR_HMLAMP Command 53 9.9.8 CR_LAMPLIFECONTRL Command 53 9.10 Sound Status Read
  • Sanyo PLC-XW250 | RS232 Expand - Page 7
    PLC-XW200/250 Expand Serial Command Functional Specifications 9.12.3 9.12.4 9.12.5 9.12.6 9.12.7 9.12.8 CR_VMUTE Command 61 CR_FREEZE Command 61 CR_PTIMER Command 62 CR_TEMPWARN Command 62 CR_TEMP Command 63 CR_TEMPFAIL Command 64 6 / 64
  • Sanyo PLC-XW250 | RS232 Expand - Page 8
    /250 Expand Serial Command Functional Specifications 1. Overview 1.1 This Functional Specification defines communication functions for PLC-XW200/250. 1.2 Compatible to Firmware Ver. 1.x of the projector. 1.3 Most commands can be used to control projector remotely from PC by RS-232C. Therefore, the
  • Sanyo PLC-XW250 | RS232 Expand - Page 9
    PLC-XW200/250 Expand Serial Command Functional Specifications 3. Notes for communication 1. Expand power. During this time commands cannot be processed. Do not issue any command. 4. Name Definition 1. Data from a controller to a projector is represented as COMMAND, and data from a projector
  • Sanyo PLC-XW250 | RS232 Expand - Page 10
    PLC-XW200/250 Expand Serial Command Functional Specifications 5. Functional Execution Command Table 5.1 Image Command Table Execute command Set /Cancel Progressive Scan Set/Cancel Noise reduction Set Image mode Reset/Store for Image Adjustment 5.2 PC Adjust Control Command Table Execute command
  • Sanyo PLC-XW250 | RS232 Expand - Page 11
    time Set Power ON Start function Select Remote Control Reception Code Disable RC/Projector keys Input PIN code to release PJ Locj Select Fan mode Select Fan control mode Set channel of Closed caption Set color of Closed caption Set time when Filter warning OSD is displayed Reset Filter used time
  • Sanyo PLC-XW250 | RS232 Expand - Page 12
    PLC-XW200/250 Expand Serial Command Functional Specifications 6. Status Read Command Table 6.1 Image Status Read Command Table Status read command CR_BRIGHT[CR] CR_CONT[CR] CR_COLOR[CR] CR_TINT[CR] CR_SHARP[CR] CR_GAMMA[CR] CR_WBAL-R[CR] CR_WBAL-G[CR] CR_WBAL-B[CR]
  • Sanyo PLC-XW250 | RS232 Expand - Page 13
    Lamp replacement time Get lamp total running time Get corresponding lamp use time Get Lamp Mode status Get lamp lighting status Get projector total running time Get lamp number Get lamp life of Power management Get setting time for Power management Get setting status of ON Start Get selected Remote
  • Sanyo PLC-XW250 | RS232 Expand - Page 14
    PLC-XW200/250 Expand Serial Command Functional Specifications 7. Error Code Table Error Code ? 101 Contents -When the received data cannot be decoded -Parameter determination error (digit number error, including invalid value, etc.) The
  • Sanyo PLC-XW250 | RS232 Expand - Page 15
    Except "000" , when it is unable to execute command by any specific reason. See Error Code Table for details 3. When the received data cannot be decoded, the projector returns "?" [CR] 8.2 Transfer Example When setting projector's total dots to 1344 by Expand Serial Command PC → PJ: "CF_TDOTS_1344
  • Sanyo PLC-XW250 | RS232 Expand - Page 16
    Functional Specifications 8.4 Image Command 8.4.1 CF_BRIGHT Command Command "CF_BRIGHT_%1"[CR] "000~063 Directly select Brightness setting value %1 "UP Current Brightness setting value + 1 "DN Current Brightness setting value - 1 Details Set Brightness value of user control Projector
  • Sanyo PLC-XW250 | RS232 Expand - Page 17
    Serial Command Functional Specifications 8.4.5 CF_SHARP Command Command "CF_SHARP_%1"[CR] "000~015 Directly select Sharpness setting value %1 "UP Current Sharpness setting value + 1 "DN Current Sharpness setting value - 1 Details Set Sharpness value of user control Projector does not save
  • Sanyo PLC-XW250 | RS232 Expand - Page 18
    PLC-XW200/250 Expand Serial Command Functional Specifications Acceptable "000"[CR] Response Unacceptable "Error Code"[CR] with a sharp, powerful picture tone) "STAND Standard (Image adjust value is set to factory default) "REAL Real (Fixed value to display graphic image with natural tone)
  • Sanyo PLC-XW250 | RS232 Expand - Page 19
    PLC-XW200/250 Expand Serial Command Functional Specifications Details Select Image Mode Parameter "CUSTOM1" to "CUSTOM4" is the same as "Image1" to "Image4" displayed when selecting Image on OSD menu. The value set by this command is stored in EEPROM and its setting is effective even after ALL is
  • Sanyo PLC-XW250 | RS232 Expand - Page 20
    PLC-XW200/250 Expand Serial Command Functional Specifications 8.5 PC Adjust Control Command 8.5.1 CF_FSYNC Command Command so that it returns its original when projector turning into Stanby mode or ALL is OFF. This command is available in normal Power ON status. Acceptable "000"[CR] Response
  • Sanyo PLC-XW250 | RS232 Expand - Page 21
    PLC-XW200/250 Expand Serial Command Functional Specifications Acceptable "000"[CR] Response Unacceptable "101"[CR] ---- when so that it returns its original when projector turning into Stanby mode or ALL is OFF. This command is available in normal Power ON status. Acceptable "000"[CR] Response
  • Sanyo PLC-XW250 | RS232 Expand - Page 22
    PLC-XW200/250 Expand Serial Command Functional Specifications 8.5.8 CF_PCSTORE Command Command "CF_PCSTORE_%1"[CR] "MODE1" ---- Store current PC to Mode1-Mode5 in PC Adjust MENU. This command is available in normal Power ON status. Acceptable "000"[CR] Response Unacceptable "101"[CR] ---- When
  • Sanyo PLC-XW250 | RS232 Expand - Page 23
    PLC-XW200/250 Expand Serial Command Functional Specifications 8.6 Input Control Command 8.6.1 CF_INPUT Command Command "CF_INPUT_%1"[CR operation as "INPUT" button of the projector and Remote Control. This command is available in normal Power ON status. Projector returns "101" by selecting Computer
  • Sanyo PLC-XW250 | RS232 Expand - Page 24
    PLC-XW200/250 Expand Serial Command Functional Specifications 8.6.3 CF_INPUT1 Command Command "CF_INPUT1_%1_"[CR] "ANALOG Select Analog by %1 at the same time. This command is available in normal Power ON status. Projector returns "101" by selecting Computer 2 while Monitor out is selected in
  • Sanyo PLC-XW250 | RS232 Expand - Page 25
    PLC-XW200/250 Expand Serial Command Functional Specifications 8.6.7 CF_SYSTEM Command Command "CF_SYSTEM_%1"[CR] %1 is inappropriate for selected Input, the projector returns "101"[CR] and the command is not executed This command is available in normal Power ON status. Details Note1) "NTSC" /
  • Sanyo PLC-XW250 | RS232 Expand - Page 26
    PLC-XW200/250 Expand Serial Command Functional Specifications →Normal) Select image size on screen. When Input specified by %1 is inappropriate for selected Input, the projector returns "101" Zoom When image is expanded or shrunk, reset its value. This command is available in normal Power ON status
  • Sanyo PLC-XW250 | RS232 Expand - Page 27
    PLC-XW200/250 Expand Serial Command Functional Specifications store mode to Reset Details Set Keystone store mode This command is available in normal Power ON status. available in normal Power ON status. Note1) When Screen setting is not in Custom mode, projector changes image mode into Custom
  • Sanyo PLC-XW250 | RS232 Expand - Page 28
    PLC-XW200/250 Expand Serial Command Functional Specifications This command is available in normal Power ON status. Note1) When Screen setting is not in Custom mode, projector changes image mode into Custom by receiving this command. Note2) When there is no signal detected, projector returns 101 and
  • Sanyo PLC-XW250 | RS232 Expand - Page 29
    PLC-XW200/250 Expand Serial Command Functional Specifications 8.8 Lamp Command 8.8.1 CF_LAMPH Command Command "CF_LAMPH_%1"[CR] %1 "RST" Details Reset total lamp running time This command is available in normal Power ON status. Acceptable "000"[CR] Response Unacceptable "Error Code"[CR]
  • Sanyo PLC-XW250 | RS232 Expand - Page 30
    PLC-XW200/250 Expand Serial Command Functional Specifications 8.9 Sound Command 8.9.1 CF_VOLUME Command Command "CF_VOLUME_%1"[ operation. The value set by this command is stored in Projector. This command is available in normal Power ON status. Acceptable "000"[CR] Response Unacceptable "Error
  • Sanyo PLC-XW250 | RS232 Expand - Page 31
    PLC-XW200/250 Expand Serial Command Functional Specifications 8.10 Setting Command 8.10.1 CF_LANG Command Command " This command is available in normal Power ON status. Note) It is unable to set Keystone, PC ADJ. and Input search to OFF at once. e.g. If projector receives Input search OFF command
  • Sanyo PLC-XW250 | RS232 Expand - Page 32
    ] "BLUE Select Blue Back "USER Select User %1 "BLACK Select Black Back "UP Switch forward (Blue Back→User→Black Back→Blue Back) "DN" --------- Switch backward (Blue Back→Black Back→User→Blue Back) Details Set Screen status for no signal.(Available only in the normal Power ON status) The
  • Sanyo PLC-XW250 | RS232 Expand - Page 33
    PLC-XW200/250 Expand Serial Command Functional Specifications Power ON Default Logo "USER Display Captured Logo %2 "UP Switch Logo setting in positive order (OFF → DFLT → User → OFF → ) "DN Switch Logo setting in negative order (OFF → User Projector returns Error Code "101" by receiving USER
  • Sanyo PLC-XW250 | RS232 Expand - Page 34
    PLC-XW200/250 Expand Serial Command Functional Specifications 8.10.10 CF_CEIL Command Command "CF_CEIL_%1"[CR] in normal Power ON status. Terminal means Computer 2 in this model. Acceptable "000"[CR] Response "Error Code"[CR] Unacceptable When Input is Computer 2, the projector returns "101
  • Sanyo PLC-XW250 | RS232 Expand - Page 35
    PLC-XW200/250 Expand Serial Command Functional Specifications 8.10.14 CF_P-MANE Command Command "CF_P MANE_%1"[CR] "OFF Set Power Management to OFF "READY Set Power Management to Ready "SHUTDOWN Set Power Management to Shut Down mode %1 "UP Switch Power management setting Off → Ready →
  • Sanyo PLC-XW250 | RS232 Expand - Page 36
    PLC-XW200/250 Expand Serial Command Functional Specifications Response after ALL is OFF This command is available in normal Power ON status. Acceptable "000"[CR] Unacceptable "Error Code"[CR] 8.10.18 CF_KEYDIS Command Command "CF_KEYDIS_%1"[CR] "NONE RC & Projector keys are valid (All are
  • Sanyo PLC-XW250 | RS232 Expand - Page 37
    PLC-XW200/250 Expand Serial Command Functional Specifications is available in normal Power ON status. Closed caption 200 Set 200 hours "300 Set 300 hours "OFF No warning display %1 "UP Switch Filter timer forward Off →100 → 200 → 300 → Off "DN Switch Filter timer backward Off → 300 → 200
  • Sanyo PLC-XW250 | RS232 Expand - Page 38
    PLC-XW200/250 Expand Serial Command Functional Specifications Details Response Set timer of Filter replacement /clean-up warning display. Acceptable "000"[CR] Unacceptable "Error Code"[CR] 8.10.25 CF_FILH Command Command "CF_FILH_%1"[CR] %1 "RST Reset Filter used time Details Reset filter
  • Sanyo PLC-XW250 | RS232 Expand - Page 39
    PLC-XW200/250 Expand Serial Command Functional Specifications keys of Remote Control / Projector Auto PC adj. keeps operating even though projector receives this Power ON projector "OFF Power OFF Projector Note1) Count down can be terminated by sending this command. %1 Note2) Projector
  • Sanyo PLC-XW250 | RS232 Expand - Page 40
    normal Power ON status. Acceptable "000"[CR] Response Unacceptable "Error Code"[CR] 8.11.6 CF_PTIMER Command Command "CF_PTIMER_%1"[CR] %1 "SET Excute P-TIMER Details Display / Suspend / Cancel P-TIMER This command behaves the same as "P-TIMER" key of Remote Control / Projector. Acceptable
  • Sanyo PLC-XW250 | RS232 Expand - Page 41
    PLC-XW200/250 Expand Serial Command Functional Specifications 9. Status Read Command 9.1 Format 1) PC issues commands in format as below: "CR_Command" [CR] Command : Character Line 2) When projector receives the appropriate command, it returns a character line as the required data "000 "%1 [CR] %1:
  • Sanyo PLC-XW250 | RS232 Expand - Page 42
    PLC-XW200/250 Expand Serial Command Functional Specifications 9.4.3 CR_COLOR Command Command "CR_COLOR"[CR] Details Get Color value of user control Acceptable "000_%a"[CR] Response %a "000"~"063" Unacceptable "Error Code"[CR] 9.4.4 CR_TINT Command Command "CR_TINT"[CR] Details Get Tint
  • Sanyo PLC-XW250 | RS232 Expand - Page 43
    PLC-XW200/250 Expand Serial Command Functional Specifications 9.4.9 CR_WBAL - B Command Command "CR_WBAL-B"[CR] Details Get White Balance Blue value of user L1" -------- Noise Reduction for moving image Response %1 "L2" -------- Noise Reduction for still image "OFF" ----- Noise Reduction is
  • Sanyo PLC-XW250 | RS232 Expand - Page 44
    PLC-XW200/250 Expand Serial Command Functional Specifications 9.4.13 CR_IMAGE Command Command "CR_IMAGE"[CR] Details Get image setting status Required data "CUSTOM1" to "CUSTOM4" is the same as "Image1" to "Image4" displayed when selecting IMAGE on OSD menu Acceptable "000_%a"[CR] "DYNAMIC
  • Sanyo PLC-XW250 | RS232 Expand - Page 45
    PLC-XW200/250 Expand Serial Command Functional Specifications 9.5 PC Adjust Status Read Command 9.5.1 CR_FSYNC Command Command "CR_FSYNC"[CR] Details Get Fine Sync value Acceptable "000_%a"[CR] Response %a Unacceptable "0000"~"0031" "Error Code"[CR] -----
  • Sanyo PLC-XW250 | RS232 Expand - Page 46
    PLC-XW200/250 Expand Serial Command Functional Specifications 9.5.6 CR_DDOTS Command Command "CR_DDOTS"[CR] Details Get Display Dots value Acceptable "000_%a"[CR] Response %a "0256"~"nnnn" (nnnn = Total Dots - Horizontal Position value) Unacceptable "Error Code"[
  • Sanyo PLC-XW250 | RS232 Expand - Page 47
    PLC-XW200/250 Expand Serial Command Functional Specifications 9.6 Video Status Read Command 9.6.1 CR_SERSYS Command Command "CR_SERSYS"[CR] Details Get currently selected signal Returns auto-detected signal in Auto mode Only available for Video
  • Sanyo PLC-XW250 | RS232 Expand - Page 48
    PLC-XW200/250 Expand Serial Command Functional Specifications 9.7 Input Status Read Command 9.7.1 CR_INPUT Command Command "CR_INPUT"[CR] Details Get selected INPUT No. Acceptable "000_%1"[CR] Response Request data "1"-"3" Unacceptable "Error Code"[CR] 9.7.2 CR_SOURCE
  • Sanyo PLC-XW250 | RS232 Expand - Page 49
    PLC-XW200/250 Expand Serial Command Functional Specifications 9.7.6 CR_SYSTEM Command Command "CR_SYSTEM"[CR] Cr Input is Video,S-Vi deo Unacceptable "MODE5 Mode5 is selected When there is no signal, projector returns error code"101" [CR] "AUTO Auto is selected "1080i 1080i is selected "1035i
  • Sanyo PLC-XW250 | RS232 Expand - Page 50
    PLC-XW200/250 Expand Serial Command Functional Specifications 9.7.7 CR_SYSLIST Command Command "CR_SYSLIST"[CR] Details Get selectable System titles Acceptable "000_%1_%2_..._%x" [CR] - When Input is PC-Analog "XGA1 XGA1is selectable "1080I 1080i is selectable Projector does not return Auto,Mode1
  • Sanyo PLC-XW250 | RS232 Expand - Page 51
    PLC-XW200/250 Expand Serial Command Functional Specifications 9.8 Screen Status Read Command 9.8.1 CR_SCREEN Command Command "CR_SCREEN"[CR] Details Get selected on-screen image Store mode is "Store" "RST Store mode is "Reset" Unacceptable "Error Code"[CR] 9.8.3 CR_VSCALE Command Command "
  • Sanyo PLC-XW250 | RS232 Expand - Page 52
    PLC-XW200/250 Expand Serial Command Functional Specifications 9.8.6 CR_HPOS Command Command "CR_HPOS"[CR] Details Get setting status of Horizontal Position Store Mode Acceptable "000_%1"[CR] Response %1 "-15" ~ "015" Unacceptable "Error Code"[CR] 51 / 64
  • Sanyo PLC-XW250 | RS232 Expand - Page 53
    PLC-XW200/250 Expand Serial Command Functional Specifications 9.9 Lamp Status Read Command 9.9.1 CR_LAMPREPL Command Command "CR_LAMPREPL"[CR] Details Get information of Lamp Replacement time Acceptable "000_%1"[CR] "1Y Over lamp replacement time "1N Within lamp replacement time Response %1
  • Sanyo PLC-XW250 | RS232 Expand - Page 54
    PLC-XW200/250 Expand Serial Command Functional Specifications 9.9.5 CR_LAMPMSTS Command Command "CR_LAMPSTS"[CR] Details Get Lighting status of lamp Acceptable "000_%1"[CR] "n**** " A number of * should be among 1-4. First character shows how many lamps are incorporated in projector Lamp life
  • Sanyo PLC-XW250 | RS232 Expand - Page 55
    PLC-XW200/250 Expand Serial Command Functional Specifications 9.10 Sound Status Read Command 9.10.1 CR_VOLUME Command Command "CR_VOLUME"[CR] Details Get Volume value of user control Acceptable "000_%a"[CR] Response %a "000"~"031" Unacceptable "Error Code" [CR] 9.10.2 CR_MUTE Command
  • Sanyo PLC-XW250 | RS232 Expand - Page 56
    PLC-XW200/250 Expand Serial Command Functional Specifications 9.11 Setting Status Read Command 9.11.1 CR_LANG Command Command " Acceptable "000_%a"[CR] "AUTO Auto Keystone is Auto Response %a "MANUAL Auto Keystone is Manual "OFF Auto Keystone is OFF Unacceptable "Error Code"[CR] 55 /
  • Sanyo PLC-XW250 | RS232 Expand - Page 57
    PLC-XW200/250 Expand Serial Command Functional Specifications 9.11.5 CR_BACKGND Command Command "CR_BACKGND" [CR] Details Get setting status of Screen for no signal Acceptable "000_%1" [CR] Response "BLUE Blue Back is selected %1 "USER User is selected "BLACK Black Back is selected
  • Sanyo PLC-XW250 | RS232 Expand - Page 58
    PLC-XW200/250 Expand Serial Command Functional Specifications 9.11.10 CR_TERMINAL Command Command "CR_TERMINAL" 11.13 CR_P-MANETIME Command Command "CR_P-MANETIME"[CR] Details Get time to start Power Management Acceptable "000_%a"[CR] Response %a "001"~"030 1 minute to 30 minutes
  • Sanyo PLC-XW250 | RS232 Expand - Page 59
    PLC-XW200/250 Expand Serial Command Functional Specifications 9.11.15 CR_RCODE Command Command "CR_RCODE"[CR] Details Get selected Remote ON-1 or ON-2 on Menu, and PJ PIN CODE is not entered so that projector is actually locked. Response %1 "FREE PJ Lock is released. PJ Lock status is
  • Sanyo PLC-XW250 | RS232 Expand - Page 60
    PLC-XW200/250 Expand Serial Command Functional Specifications 9.11.20 CR_FANMODE Command Command "CR_FANMODE"[CR] Details "Error Code" [CR] 9.11.22 CR_FILH Command Command "CR_FILH"[CR] Details Get Filter used time Acceptable "000_%1"[CR] Response %1 "00000"~"99999 0 hour to 99999 hours
  • Sanyo PLC-XW250 | RS232 Expand - Page 61
    PLC-XW200/250 Expand Serial Command Functional Specifications 9.11.25 CR_FILREPL Command Command "CR_FILREPL"[CR] Details Get the information of Filter replacement time Acceptable "000_%1"[CR] Response %1 "1Y Over filter replacement time "1N Within filter replacement time Unacceptable "
  • Sanyo PLC-XW250 | RS232 Expand - Page 62
    Specifications 9.12 Other Status Read Command 9.12.1 CR_STATUS Command Command "CR_STATUS"(CR) Details Get status of Projector behavior. This command affects the same as "CR0" of Basic Serial command, but this has an error code. Acceptable "000_%1"[CR] "00"= Power Show is ON, User Logo (My
  • Sanyo PLC-XW250 | RS232 Expand - Page 63
    PLC-XW200/250 Expand Serial Command Functional Specifications 9.12.5 CR_PTIMER Command Command "CR_PTIMER"[CR] Details CR_TEMPWARN Command Command "CR_TEMPWARN"[CR] Details Get the temperature inside a projector and its condition if it is abnormal temperature or close to abnormal temperature
  • Sanyo PLC-XW250 | RS232 Expand - Page 64
    PLC-XW200/250 Expand Serial Command Functional Specifications 9.12.7 CR_TEMP Command Command "CR_TEMP"[CR] Details Get current temperature inside a projector high to display Warning) "S" ------- the projectors get abnormal temperature because of heat of Lamp ballast in Standby mode or Powering ON
  • Sanyo PLC-XW250 | RS232 Expand - Page 65
    PLC-XW200/250 Expand Serial Command Functional Specifications 9.12.8 CR_TEMPFAIL Command Command "CR_TEMPFAIL"[CR] Details Get the temperature inside a projector is safe, all data are represented as "□000S". When the projector is reset, "□000S" is set, and every time abnormal temperature occurs,
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65

EXPAND SERIAL COMMAND
FUNCTIONAL SPECIFICATIONS
PLC-XW200
PLC-XW250
Ver. 1.01
SANYO Electric Co., Ltd
DS Company
Projector Division