    BASIC SERIAL COMMAND FUNCTIONAL SPECIFICATIONS PLC-ZM5000 PLC-ZM5000L Ver.1.00 SANYO Electric Co., Ltd DS Company Projector Division
  • Sanyo PLC-ZM5000L | RS232C Basic - Page 2
    PLC-ZM5000/ZM5000L Basic Serial Command Functional Specifications Contents 1. Overview...5 2. Serial Interface Specification 5 2.1. Transfer Specification Operation Requirements 11 6.5 POWER ON Command 12 6.6 POWER OFF Command (Quick POWER OFF 12 6.7 POWER OFF Command 12 6.8 INPUT 1 Command 12
  • Sanyo PLC-ZM5000L | RS232C Basic - Page 3
    PLC-ZM5000/ZM5000L Basic Serial Command Functional Specifications 6.32 POWER MANAGEMENT CANCEL Command 16 6.33 POWER 1 DVI (AV HDCP) Command 20 6.55 LENS SHIFT UP Command 20 6.56 LENS SHIFT DOWN Command 20 6.57 LENS SHIFT LEFT Command 21 6.58 LENS SHIFT RIGHT Command 21 6.59 AUTO PC ADJ.
  • Sanyo PLC-ZM5000L | RS232C Basic - Page 4
    PLC-ZM5000/ZM5000L Basic Serial Command Functional Specifications 7.6 Lamp Time Read Command 27 7.7 Setting Read Command 27 7.8 Temp Read Command 28 7.9 Lamp Mode Read Command 28 4/28
  • Sanyo PLC-ZM5000L | RS232C Basic - Page 5
    PLC-ZM5000/ZM5000L Basic Serial Command Functional Specifications 1. Overview These specifications define projector control commands for PLC-ZM5000/ZM5000 L The projector control commands are used to control a projector through RS-232C from a computer. 2. Serial Interface Specification 2.1.
  • Sanyo PLC-ZM5000L | RS232C Basic - Page 6
    PLC-ZM5000/ZM5000L Basic Serial Command Functional Specifications 3. Notes for Communication The projector ZOOM UP/DOWN", "FOCUS UP/DOWN" and "LENS-SHIFT UP/DOWN/RIGHT" --> 100ms 2) Other mode, when the command for internal initialization or lamp lighting is received, ACK value is returned but
  • Sanyo PLC-ZM5000L | RS232C Basic - Page 7
    PLC-ZM5000/ZM5000L Basic Serial Command Functional Specifications 4. Functional Execution Command Table Command C00 C01 C02 C03 C04 C05 C06 C07 C08 C09 C0A C0B C0C C0D C0E C0F C10 C11 C12 C13 C14 C15 C16 C17 C18 C19 C1A C1B C1C C1D C1E C1F Item POWER ON POWER OFF (QUICK POWER OFF) POWER OFF ----
  • Sanyo PLC-ZM5000L | RS232C Basic - Page 8
    PLC-ZM5000/ZM5000L Basic Serial Command Functional Specifications Command C40 C41 C42 C43 C44 C45 C46 C47 C48 C49 C4A C4B C4C C4D C4E C4F C50 C51 C52 C53 C54 C55 C56 C57
  • Sanyo PLC-ZM5000L | RS232C Basic - Page 9
    PLC-ZM5000/ZM5000L Basic Serial Command Functional Specifications 5. Status Read Command Table Command CR0 Item STATUS READ CR1 CR2 INPUT MODE READ --- CR3 CR4 LAMP TIME READ SETTING READ CR5 CR6 CR7 --TEMP READ LAMP MODE READ CR8 --- CR9 --- CRA --- CRB --- CRC --- "---" means "
  • Sanyo PLC-ZM5000L | RS232C Basic - Page 10
    PLC-ZM5000/ZM5000L Basic Serial Command Functional Specifications 6. Functional Execution Command 6.1 Format PC issues a command in the following format: "C" Command [CR] Command: two characters (See Functional Execution Command Table) Projector decodes the received data and returns the result when
  • Sanyo PLC-ZM5000L | RS232C Basic - Page 11
    PLC-ZM5000/ZM5000L Basic Serial Command Functional Specifications 6.4 Operation Requirements 6.4.1 In the following status of projector, Available Functional Execution Commands are limited. Projector Status Available Functional Execution Commands Standby Mode Countdown in process C00: POWER ON
  • Sanyo PLC-ZM5000L | RS232C Basic - Page 12
    PLC-ZM5000/ZM5000L Basic Serial Command Functional Specifications 6.5 POWER ON Command Command "C00" [CR] This command executes Quick Power OFF operation without displaying "Power OFF?" message, which is displayed when Power is turned OFF with ON/STAND-BY button of the projector or remote control.
  • Sanyo PLC-ZM5000L | RS232C Basic - Page 13
    PLC-ZM5000/ZM5000L Basic Serial Command Functional Specifications 6.10 INPUT 3 Command Command "C07" [CR] Detail this command does not execute the source switching; just for switching to Input 3. Although projector returns "OK", Input search is not executed with this command while Input button is
  • Sanyo PLC-ZM5000L | RS232C Basic - Page 14
    PLC-ZM5000/ZM5000L Basic Serial Command Functional Specifications 6.15 SOUND MUTE OFF Command Command "C0C" [CR] Detail Sound Mute Off. This command works the same way as "MUTE" button of the remote control
  • Sanyo PLC-ZM5000L | RS232C Basic - Page 15
    PLC-ZM5000/ZM5000L Basic Serial Command Functional Specifications 6.21 MENU OFF Command Command "C1D" [CR] Detail Clear user control. Acceptable Response [ACK] [CR] Unacceptable "?" [CR] 6.25 INPUT 2 VIDEO Command Command "C23" [CR] Detail Select Video input in Input 2. Although projector
  • Sanyo PLC-ZM5000L | RS232C Basic - Page 16
    PLC-ZM5000/ZM5000L Basic Serial Command Functional Specifications 6.27 INPUT 2 RGB Command Command "C25" [CR] Detail Select RGB input in Input 2. Although projector returns "OK", Input search is not executed with this command while Input button is set to Mode2 or Mode3. Acceptable Response [
  • Sanyo PLC-ZM5000L | RS232C Basic - Page 17
    PLC-ZM5000/ZM5000L Basic Serial Command Functional Specifications 6.33 POWER MANAGEMENT SHUTDOWN Command Cr Command Command "C35" [CR] Detail Select Y,Pb/Cb,Pr/Cr input in Input 3. Although projector returns "OK", Input search is not executed with this command while Input button is set to Mode2
  • Sanyo PLC-ZM5000L | RS232C Basic - Page 18
    PLC-ZM5000/ZM5000L Basic Serial Command Functional Specifications 6.39 POINTER RIGHT Command Command "C3A" [CR] Detail Move the Pointer of On-Screen Display Menu to the right. This command works differently from the command by Point button ">" of the projector or remote control and has no "
  • Sanyo PLC-ZM5000L | RS232C Basic - Page 19
    PLC-ZM5000/ZM5000L Basic Serial Command Functional Specifications Adjust on-screen focus by making focal length longer. (The lens moves backward) This command works the same way as "FOCUS CR] Detail Select HDMI input in Input 1. Although projector returns "OK", Input search is not executed with
  • Sanyo PLC-ZM5000L | RS232C Basic - Page 20
    PLC-ZM5000/ZM5000L Basic Serial Command Functional Specifications 6.51 INPUT 1 ANALOG RGB Command Command "C50" [CR] Detail Select Analog RGB input in Input 1. Although projector Response [ACK] [CR] Unacceptable "?" [CR] 6.55 LENS SHIFT UP Command Command "C5D" [CR] Detail Move projection
  • Sanyo PLC-ZM5000L | RS232C Basic - Page 21
    PLC-ZM5000/ZM5000L Basic Serial Command Functional Specifications 6.57 LENS SHIFT LEFT Command Command "C5F" [CR] Detail Move projection area leftward. Acceptable Response [ACK] [CR] Unacceptable "?" [CR] 6.58 LENS SHIFT RIGHT Command Command "C60" [CR] Detail Move projection area
  • Sanyo PLC-ZM5000L | RS232C Basic - Page 22
    PLC-ZM5000/ZM5000L Basic Serial Command Functional Specifications 6.63 KEYSTONE ↓ Command Command "C8F" [CR] Detail Correct keystone distortion by reducing lower part of image. This command invokes both operations of keystone distortion correction
  • Sanyo PLC-ZM5000L | RS232C Basic - Page 23
    PLC-ZM5000/ZM5000L Basic Serial Command Functional Specifications 7 Status Read Command 7.1 Format PC issues a command in the following format. "CR" Command [CR] Command: one character (See Status Read Command Table) When projector receives an appropriate command, it returns the required data in
  • Sanyo PLC-ZM5000L | RS232C Basic - Page 24
    PLC-ZM5000/ZM5000L Basic Serial Command Functional Specifications 7.4 Status Read Command Command "CR0" [CR] Detail Get the projector processing Countdown is not executed and the status quickly moves to Power ON. "20" [CR] moves to Cooling Down status. When lamp turns off and about 90 seconds of
  • Sanyo PLC-ZM5000L | RS232C Basic - Page 25
    PLC-ZM5000/ZM5000L Basic Serial Command Functional Specifications "10" [CR] Status: Power Failure When the power supply voltage inside the projector reaches abnormal status, the projector is automatically turned off. Abnormal power supply voltage includes; Filter abnormal status Shutter abnormal
  • Sanyo PLC-ZM5000L | RS232C Basic - Page 26
    PLC-ZM5000/ZM5000L Basic Serial Command Functional Specifications "04" [CR] Status: Power Save This indicates it moves to Power-Save status by Power Management function as set in the Setting menu. "21" [CR] Status: Cooling Down in process after OFF due to Lamp Failure When the projector is turned
  • Sanyo PLC-ZM5000L | RS232C Basic - Page 27
    PLC-ZM5000/ZM5000L Basic Serial Command Functional Specifications 7.5 Input Mode Read Command Command "CR1" [CR] Detail Get currently selected Input No. "?" [CR] 7.6 Lamp Time Read Command Command "CR3" [CR] Detail Get total lamp running hours. *return lamp operating time multiplied by
  • Sanyo PLC-ZM5000L | RS232C Basic - Page 28
    PLC-ZM5000/ZM5000L Basic Serial Command Functional Specifications 7.8 Temp Read Command Command "CR6" [CR] Detail Get the information of temperature inside a projector hardware problems, it %3 starts with "E" like"E00.0" [CR]. With several built-in temperature sensors, the projector returns
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

BASIC SERIAL COMMAND
FUNCTIONAL SPECIFICATIONS
PLC-ZM5000
PLC-ZM5000L
Ver.1.00
SANYO Electric Co., Ltd
DS Company
Projector Division