- Sharp AF-S155NX | AF-S155NX Operation Manual - Page 1
AF-S155NX N - Sharp AF-S155NX | AF-S155NX Operation Manual - Page 2
- Sharp AF-S155NX | AF-S155NX Operation Manual - Page 3
- Sharp AF-S155NX | AF-S155NX Operation Manual - Page 4
HEAD BOLT WINDOW SUPPORT BRACKET SILLANGLE BRACKET 3. Check your storm windows - if your storm window frame does not allow the clearance required, correct by adding a piece of wood as shown in FIG.2, or by removing storm window while room air conditioner is being installed. (continued) FIG. 2 SASH - Sharp AF-S155NX | AF-S155NX Operation Manual - Page 5
48"long. Be sure you have an outlet near. All models have a 3-prong service plug to provide proper service and safe positive grouding. Do not change plug in any way air conditioner - remove all packing material. Protect floor or carpet from damage. Two people should be used to move and install - Sharp AF-S155NX | AF-S155NX Operation Manual - Page 6
base if installed. 7. Hold the cabinet while pulling on the base handle, and care- fully remove the unit. 8. Add two foam inserts to holes in top of cabinet where shipping screws were removed from. FIG. 7 PLASTIC FRAME WINDOW FILLER PANEL FIG. 8 SIDE RETAINER TOP VIEW AIR CONDITIONER CABINET - Sharp AF-S155NX | AF-S155NX Operation Manual - Page 7
slide freely. Screws will be tightened after Section 6. 4 Place Cabinet in Window 1. Open window and mark center of window stool. 5 Install Support Bracket 1. Hold each support bracket flush against outside of sill, and tight to bottom of cabinet as shown below. Mark brackets at top level of - Sharp AF-S155NX | AF-S155NX Operation Manual - Page 8
window to expose filler panel locking screws. Loosen screws so filler panels slide easily. LOCKING SCREWS 8 Install Chassis into Cabinet and Install Front to Unit 1. Lift air conditioner and carefully slide into cabinet leaving 6" protruding. 2. DO not push on controls OR finned coils. 3. Be - Sharp AF-S155NX | AF-S155NX Operation Manual - Page 9
- Sharp AF-S155NX | AF-S155NX Operation Manual - Page 10
- Sharp AF-S155NX | AF-S155NX Operation Manual - Page 11
- Sharp AF-S155NX | AF-S155NX Operation Manual - Page 12
TO CHANGE TEMPERATURE SETTING: YOU WILL SEE: DO THIS: PRESS TO RAISE PRESS TO LOWER Note: Tap or hold either up ( ) or down ( ) button until the desired temperature is seen on the display. This temperature will be automatically maintained anywhere between 60oF (16oC) and 90oF (32oC) for cooling - Sharp AF-S155NX | AF-S155NX Operation Manual - Page 13
WILL SEE: DO THIS: PRESS MODE BUTTON CHOOSE FAN Note: Use this function only when cooling is not desired, such as for room air circulation or to exhaust stale air. (Remember to open the vent during this function, but keep it closed during cooling for maximum cooling efficiency.) You can choose any - Sharp AF-S155NX | AF-S155NX Operation Manual - Page 14
AS", a sensor has failed. Contact your Authorized SHARP Service Center. Fresh Air Vent Control The Fresh Air Vent allows the air conditioner to: 1. Recirculate inside air - Vent Closed (see Fig. 1) 2. Draw fresh air into the room - Vent Open (see Fig. 2) 3. Exchange air from the room and draws fresh - Sharp AF-S155NX | AF-S155NX Operation Manual - Page 15