Sharp EL501WBBK Operation Manual

Sharp EL501WBBK - 10 Digit 131 Function Calculator Manual

Sharp EL501WBBK manual content summary:

  • Sharp EL501WBBK | Operation Manual - Page 1
    Symbol INTRODUCTION Thank you for purchasing the SHARP Scientific Calculator Model EL-501W. About the calculation examples (including some formulas and tables), refer to the reverse side of this English manual. Refer to the number on the right of each title on the manual for use. After reading this
  • Sharp EL501WBBK | Operation Manual - Page 2
    ) SCIENTIFIC CALCULATIONS • Calculate in Calculations This calculator allows the previous calculation result to be used in the following calculation. The previous calculation result will not be recalled after entering multiple instructions. Time, Decimal and Sexagesimal Calculations This calculator
  • Sharp EL501WBBK | Operation Manual - Page 3
    inputting the number press a. When inputting the imaginary part, after inputting the number press b. To obtain the result press =. • Immediately after completing calculation, you can recall the value of the real part with a, and the value of the imaginary part with b. • If the complex numbers are
  • Sharp EL501WBBK | Operation Manual - Page 4
    in the calculator. • Batteries are factory-installed before shipment, and may be exhausted before they reach the service life stated in operation manual, quick reference card and hard case FOR MORE INFORMATION ABOUT SCIENTIFIC CALCULATOR Visit our Web site. http://sharp-world.com/calculator/
  • Sharp EL501WBBK | Operation Manual - Page 5
    EL-501W CALCULATION EXAMPLES ANWENDUNGSBEISPIELE EXEMPLES DE CALCUL EJEMPLOS DE CÁLCULO EXEMPLOS DE CÁLCULO ESEMPI DI CALCOLO REKENVOORBEELDEN PÉLDASZÁMÍTÁSOK PŘÍKLADY VÝPOČTŮ RÄKNEEXEMPEL LASKENTAESIMERKKEJ UDREGNINGSEKSEMPLER CONTOH-CONTOH PENGHITUNGAN CONTOH-CONTOH PERHITUNGAN ªæøº 3× 3 * 3.
  • Sharp EL501WBBK | Operation Manual - Page 6
    6+4=ANS ANS+5 44+37=ANS √ANS= ª 6 + 4 = + 5 = 44 + 37 = ⁄ ´¨ 12°39'18"05 → [10] ª 12.391805 ´ 123.678 → [60] 123.678 @¨ sin62°12'24" = [10] 62.1224 ´s 10. 15. 81. 9. 12.65501389 123.404080 0.884635235 DEG RAD GRAD θ = sin-1 x, θ = tan-1 x -90 ≤ θ ≤ 90 - -π2 2 -100 ≤ θ ≤ 100 g 90°→ [rad] →
  • Sharp EL501WBBK | Operation Manual - Page 7
    πab{} (12-6i) + (7+15i) - (11+4i) = CPLX @ π 0. 12 a 6 ±b+ 7 a 15 b - 11 a 4 b= 8. b 5. a 8. 6×(7-9i) × (-5+8i) = 6 a* 7 a 9 ±b* 5 ±a 8 b= 222. b 606. 16×(sin30°+icos30°) = 16 a* 30 sa 30 ub (sin60°+icos60°) / 60 sa 60 ub = 13.85640646 b 8. y A r1 r θ1 θ r2 B θ2 x 8 a 70
  • Sharp EL501WBBK | Operation Manual - Page 8
    •••• tanh x sinh-1 x cosh-1 x tanh-1 x x2 ¿x 1/x n! | x | < 10100 | x | < 5 × 1099 1 ≤ x < 5 × 1099 | x | < 1 | x | < 1050 0 ≤ x < 10100 | x | < 10100 (x ≠ 0) 0 ≤ n ≤ 69* →D.MS →DEG x, y → r, θ r, θ → x, y | x | < 1 × 10100 | x |, | y | < 1050 | -yx |, x2 + y2 < 10100 0 ≤ r < 10100 DEG: | θ | <
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

EL-501W
SCIENTIFIC CALCULATOR
OPERATION MANUAL
MODEL
ENGLISH
INTRODUCTION
Thank you for purchasing the SHARP Scientific Calculator
Model EL-501W.
About the
calculation examples (including some formulas
and tables)
, refer to the reverse side of this English manual.
Refer to the number on the right of each title on the
manual for use
.
After reading this manual, store it in a convenient location for
future reference.
Operational Notes
Do not carry the calculator around in your back pocket, as
it may break when you sit down. The display is made of
glass and is particularly fragile.
Keep the calculator away from extreme heat such as on a
car dashboard or near a heater, and avoid exposing it to
excessively humid or dusty environments.
Since this product is not waterproof, do not use it or store
it where fluids, for example water, can splash onto it.
Raindrops, water spray, juice, coffee, steam, perspiration,
etc. will also cause malfunction.
Clean with a soft, dry cloth. Do not use solvents or wet
cloth.
Do not drop it or apply excessive force.
Never dispose of batteries in a fire.
Keep batteries out of the reach of children.
This product, including accessories, may change due to
upgrading without prior notice.
SHARP will not be liable nor responsible for any inciden-
tal or consequential economic or property damage caused
by misuse and/or malfunctions of this product and its
peripherals, unless such liability is acknowledged by law.
Press the RESET switch (on the back), with the tip of a
ball-point pen or similar object, only in the following cases.
Do not use an object with a breakable or sharp tip. Note
that pressing the RESET switch erases all data stored in
memory.
When using for the first time
After replacing the batteries
To clear all memory contents
When an abnormal condition occurs and all keys are
inoperative.
If service should be required on this calculator, use only a
SHARP servicing dealer, SHARP approved service facility,
or SHARP repair service where available.
Hard Case
(During actual use not all symbols are displayed at the same time.)
If the value of mantissa does not fit within the range
±0.000000001 – ±9999999999, the display changes to scien-
tific notation. The display mode can be changed according to
the purpose of the calculation.
2ndF
:
Appears when
@
is pressed, indicating that the
functions shown in orange are enabled.
HYP
:
Indicates that
h
has been pressed and the hy-
perbolic functions are enabled. If
@
H
are
pressed, the symbols “
2ndF HYP
” appear, indicat-
ing that inverse hyperbolic functions are enabled.
DEG/RAD/GRAD:
Indicates angular units and changes each
time
G
is pressed. The default setting is DEG.
( )
:
Appears when a calculation with parentheses is per-
formed by pressing
(
.
BIN
:
Indicates that
@
ê
has been pressed.
Binary system mode is selected.
OCT
:
Indicates that
@
î
has been pressed.
Octal system mode is selected.
HEX
:
Indicates that
@
ì
has been pressed.
Hexadecimal system mode is selected.
CPLX
:
Indicates that
@
π
has been pressed.
Complex number mode is selected.
STAT
:
Indicates that
@
Æ
has been pressed.
Statistics mode is selected.
M
:
Indicates that a numerical value is stored in the
independent memory.
E
:
Appears when an error is detected.
PRINTED IN CHINA / IMPRIMÉ EN CHINE / IMPRESO EN CHINA
04AGK (TINSE0496THZZ)
BEFORE USING THE CALCULATOR
Key Notation Used in this Manual
In this manual, key operations are described as follows:
To specify A (HEX) : A
To specify
π
:
@
V
To specify E
x
p
:
E
Functions that are printed in orange above the key require
@
to be pressed first before the key. Numbers are not
shown as keys, but as ordinary numbers.
Power On and Off
Press
ª
to turn the calculator on, and
F
to turn it off.
Clearing Numbers
Press
ª
to clear the entries except for a numerical
value in the independent memory and statistical data.
Press
æ
to clear the number entered prior to use of
function key.
In case of one digit correction of the entered number, press
ø
(right shift key).
DISPLAY
Symbol
Mantissa
Exponent
Floating point system
Scientific notation system