Installation and Maintenance manual LED Module LED Display Kit [Models for indoor use] LED-FE012i3 LED-FE015i3 LED-FE019i3 [Models for indoor use] LED-FE012i3-110 LED-FE015i3-137 LED-FE019i3-165 LED-FE012i3-220 MODEL: LED-FE012i3, LED-FE015i3, LED-FE019i3 - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 2
English-54 Cleaning English-61 Maintenance English-62 Troubleshooting English-67 1. Display problems...67 2. Adjusting the colors on a part errors or omissions, please contact us. (4) The image shown in this manual is indicative only. If there is inconsistency between the image and the actual - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 3
About the Symbols To ensure safe and proper use of the product, this manual uses a number of symbols to prevent injury to you and others as well described below. Be sure to understand them thoroughly before reading this manual. WARNING CAUTION Failing to heed this symbol and handling the product - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 4
In case foreign matter has entered into the product, immediately disconnect the power supply and stop using the product. After the installation, if a problem such as loose screws occurs, immediately ask a technician or your retailer for repair. Do not put objects into the product. Otherwise, it may - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 5
from your body before touching the Pixel cards by touching an aluminum sash, a door knob, or some other metal object. This product can only be serviced in the country where it was purchased. English - 3 - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 6
display areas. When you install the product or when you use it for the first time after leaving it unused for a long time, follow the instructions below. The LED lamps may absorb and hold moisture during the LED module installation or if not used for a long time. Therefore, in such cases - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 7
Name Interface connectors 12 Signal input/output 34 Power input (output) 5 Status lamp (red) 6 Status lamp (blue) 7 Status lamp (green) 8 Test button 9 Handle 0 Guide pin Description Input and output connectors for the signal and AC power. To input the signal from the LED controller or the previous - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 8
A) The connectors are equipped on the top and bottom sides. There are guide pins on the top. Power hub board Power unit Receiving card (2) When (Type B) There are no connectors on the top side. There are no guide pins. Power hub board Power unit Receiving card (3) When connecting a LAN - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 9
Model name list 4 x 4 frame set 5 x 5 frame set 6 x 6 frame set 8 x 8 frame set LED-FE012i3-110 LED-FE015i3-137 LED-FE019i3-165 LED-FE012i3-220 English - 7 - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 10
Contents No. Parts Pixel card Specifications 152 x 171 mm 4 x 4 frame set 128 Quantity 5 x 5 frame 6 x 6 frame set set 200 288 8 x 8 frame set 512 Cabinet Cabinet hanger pin 1 Power bar cover plate 2 Power bar screw (M8×20) 608 x 342 mm 16 Head diameter 15 mm, thickness 5 mm, M8 - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 11
for Adjustment plates (M8×25) Screw for connecting cabinets (M8×25) LAN cable for the LED modules Alignment bar USB flash memory Safety Manual LED controller*2 LAN cable between LED controller and module*2 Power cord for the LED controller*2 Power cord*3 Hexagon socket head screw 750 mm Novastar - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 12
8 x 8 frame set ᶍ ᶋ ᶌ ᶆᶇ ᶅ ᶄ ᶃ ᶊ ᶈᶉ English - 10 - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 13
by enough people to ensure safety. • Make sure that the beams or the other structures to which the product is installed have enough strength to support the weight of the product, and make sure that the product is securely fixed. • Do not install directly the product to a surface that has not - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 14
A B C min. distance to sides min. distance to top and bottom min. distance between wall and system 60 mm 60 mm 20 mm D Recommended distance to ceiling 500 mm* E Recommended distance to floor 500 mm* *: Depending on the temperature condition. Wall mounting setting % < 40 °C & D - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 15
2. Handle Use the handles when carrying and installing the cabinet. Put the handles in their original positions after the installation work has been completed. When carrying or installing the cabinet, pull out the handles on both sides. Put the handles back after the work has been completed. 3. - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 16
Anchor points positions: 5 x 5 frame set 608 mm 608 mm 608 mm 684 mm 684 mm Anchor points positions: 6 x 6 frame set 608 mm 608 mm 608 mm 608 mm 1026 mm 684 mm Anchor points positions: 8 x 8 frame set 608 mm 608 mm 1216 mm 608 mm 608 mm 684 mm 684 mm 684 mm 342 mm English - 14 - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 17
Anchor points number and positions Frame set 4×4 Anchor points (horizontal x vertical) 3×2 Horizontal distance 608 mm Vertical distance 1026 mm Anchor size Ø10 mm 5×5 4×3 6×6 5×3 8×8 6×5 608 mm 608 mm 684 mm equally Distance top row - middle row: 1026 mm Distance middle row - bottom - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 18
5. Preparing mounting bar Attaching mounting bar connector Insert the mounting bar connector and tighten it securely with 6 screws (M6 x 14). Removing mounting bar connector Remove the 6 screws (M6 x 14) holding the mounting bar connector, and pull out the mounting bar connector. English - 16 - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 19
6. Install the mounting bars (1) Install the mounting bars on the anchor points on the wall. (2) Check the distance between the mounting bars using the alignment bars. 4 x 4 frame set Alignment bar Alignment bar 608 mm 608 mm 5 x 5 frame set Alignment bar 608 mm 608 mm 608 mm Alignment bar - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 20
6 x 6 frame set Alignment bar 608 mm 608 mm 608 mm 608 mm Alignment bar 8 x 8 frame set Alignment bar 608 mm 608 mm 1216 mm 608 mm 608 mm Alignment bar English - 18 - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 21
(3) Check the evenness using a spirit level or a laser line level and the alignment bars together. Adjust the positions if required. Wall mounted: Mounting bar installation (4 x 4 frame set) M10 screws 7. Install the power bar Remove the power bar cover and install the power bar using Power bar - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 22
Power bar screw (M8) Power bar When using the 8 x 8 frame set, use the power bar connecting part to install the power bar. English - 20 - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 23
8. Install the cabinet hanger pins to the back of the cabinets The following drawings indicate where Hangar pins are required. Insert the Hangar pins until the pitch of the screws is no longer visible. Hanger pin LED cabinet Hanger pin M8 8 mm Cabinet hanger pins installation position 4 x 4 - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 24
8 x 8 frame set Cabinet Mounting bar Mounting bar Power bar Positions for Cabinet hanger pins English - 22 - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 25
9. Install the cabinets Hook the hanger pins, which have been inserted into the cabinets, into the holes on the mounting bars starting from the lowest row. Fix temporarily the cabinets of the first row to the power bar. Check that the top edges of any two adjacent cabinets in the first row are flush - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 26
Hook the hanger pins of the cabinets of the second row to the mounting bars. Secure the LED cabinets together using screws for connecting cabinets. Do not tighten the screws completely. After you have installed two rows of cabinets, align the surfaces of the cabinets using the Adjustment plates. - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 27
When the cabinets' surfaces are aligned, securely tighten the cabinets of the first row to the power bar, the cabinets of the first row together, as well as the cabinets of the first row with the cabinets of the second row. Remove the Adjustment plates after the screws have been tightened. Follow - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 28
Install the power bar cover. Insert the slot nut into the overframe and align it with the marking line and fix them with screw for overframe screws. Use overframe screws (M4 x 4) for the right side and overframe screws (M4 x 8) for the rest. Install the corner parts to the corner frame top and - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 29
Slot nut installation locations 4 x 4 frame set 5 x 5 frame set 6 x 6 frame set Screw for overframe M4×4 Screw for overframe M4×8 8 x 8 frame set English - 27 - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 30
171 10. Assembly diagrams 4 x 4 frame set 608 608 1469.5 1368 2444 2432 BBBB AAAA AAAA AAAA 1475.5 698.5 800 800 1469.5 Through hole for the LAN cable and power code 171 360 608 608 608 260 5 x 5 frame set 608 608 608 1811.5 1710 78 3052 3040 BBBBB AAAAA AAAAA AAAAA AAAAA 1817.5 698 - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 31
2159.5 698.5 171 6 x 6 frame set 608 608 608 608 2153.5 2052 3660 3648 BBBB BB AAAA AA AAAA AA AAAA AA AAAA AA AAAA AA 800 800 2153.5 Through hole for the LAN cable and power code 360 608 608 608 608 608 260 78 8 x 8 frame set 608 608 1216 608 608 2837.5 2742 4876 4864 BBBBBBBB - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 32
11. Installation without a frame set A recommended example of installation when using the brackets is shown below. Please prepare the bracket by yourself. Ask a technician or your retailer for the installation procedure when not using the brackets. Install the brackets to the frame as shown in the - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 33
12. Wiring (1) Maximum number of signal connections The maximum number of connections per LAN cable is shown below. Product name Maximum number of connections LED-FE012i3 5 modules LED-FE015i3 7 modules LED-FE019i3 10 modules CAUTION The maximum number of connections may differ depending - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 34
(3) Connection when using a wall-mount frame This connection is an example of connection when using the maximum capacity. The power cable corresponding to the yellow part needs to be prepared by the customer. Please connect considering the capacity of the switchboard and the inrush current - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 35
5 x 5 frame set HDMI DVI AC POWER Controller (MCTRL660Pro) 5 x 5 frame set Number of power system Current rating per 1 module per power system Inrush current 25°C Cold start Pulse width: 3ms per frame set per 1 module per power system per frame set AC 100V 3 0.5 A 5.0 A (2 Systems) 2.5 A - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 36
6 x 6 frame set HDMI DVI AC POWER Controller (MCTRL660Pro) 6 x 6 frame set Number of power system Current rating per 1 module per power system per frame set Inrush current per 1 module 25°C Cold start Pulse width: 3ms per power system per frame set AC 100V 3 0.5 A 6.0 A 18.0 A 50 A 600 - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 37
8 x 8 frame set AC POWER HDMI DVI Controller (MCTRL 4K) 8 x 8 frame set Number of power system Current rating per 1 module per power system per frame set Inrush current per 1 module 25°C Cold start Pulse width: 3ms per power system per frame set AC 100V 8 0.5 A 4.0 A 32.0 A 50 A 400 A - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 38
Backside hole cabinet There are holes on the back of the cabinet for passing signal cables and power cords. backside hole If the hole is not drilled, place a flathead screwdriver from inside the cabinet at the edge of the round recess and tap it lightly with a hammer to make a hole. Cables for - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 39
Remove the cable holder fixing ring attached to the LAN cable or power cord. Remove the cable fixing part and move the cable holder to the end of the cable. Attach the cable holder to the backside hole of the cabinet and attach the cable holder fixing ring from the outside of the cabinet. Insert the - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 40
Precautions on use of the power connector (WAGO) When using the power cord connector (WAGO's product, WFR Series (WAGO 221), Models WFR-2 and WFR-3), respect the following precautions. WAGO 221 * Visiting WAGO's homepage for more details is recommended. WARNING • Always use the connector indoors ( - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 41
How to connect the power cord (1) Raise the lever. (2) Insert the wire. (3) Return the lever to its previous position. CAUTION Insufficient insertion may cause poor electricity conduction and heat generation. Power code connection checking • Perform checking for correct and proper connection. - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 42
(4) LAN cable connection Connect the LAN cables for the signal between the LED modules. Use the through holes to pass the cables between the modules. Four through holes for the LAN cables LAN connectors [Connection example] Connecting from bottom to top using multiple ports LAN cable from the LED - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 43
13. Installing the pixel card CAUTION • The pixel cards contain powerful magnets. If magnetic cards come close to the pixel cards, the data contained within may be damaged. Therefore, do not carry any magnetic card when installing the pixel cards. • When installing the pixel cards, pay attention not - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 44
(↑) at the back of the pixel cards indicate the upper side. Install the pixel card into the cabinet with the four guide holes of the pixel card aligned with the four guide pins of the cabinet (four pins for each pixel card). The pixel card is secured by the 4 magnets on each - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 45
Screen Configuration Check that all the connections are completed, and then turn on the LED modules and the LED controller. Power distributor LED controller CONTROL INPUT OUTPUT Control signal Video signal WARNING Pay attention to the wire colors of the power cord when connecting the cord. If - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 46
software by Novastar. Connect the supplied USB memory to the computer. Start NovaLCT*.exe. After it has started, install it following the software instructions. The NovaLCT preparation is complete. CAUTION For NovaLCT*.exe, be sure to use the file contained in the supplied USB drive. Using a NovaLCT - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 47
Module connection settings Start NovaLCT and log in with the administrator privileges. In the Screen Configuration screen that is displayed, select the "Screen Connection" tab (a). (a) CAUTION Do not change the settings in the "Receiving Card" tab. Otherwise, the video may not be displayed properly. - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 48
[Configuration example] The setting values are given for the following example where 16 are installed in a 4 (columns) x 4 (rows) configuration connecting from bottom to top using multiple ports. CONTROL INPUT OUTPUT (1) With a pixel pitch of 1.25 mm, enter Width=480 and Height=270 under " - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 49
(2) Since the configuration is 4 (columns) x 4 (rows), enter Columns=4 and Rows=4. A 4 (columns) x 4 (rows) screen configuration is displayed. (3) If multiple LED controllers are used, select the number of the connected LED controllers. Since only one controller is used in this example, it is not - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 50
Select the cabinet at the bottom left with the mouse, and then select the other cabinets up to the top cabinet. Then select Port2 and select the cabinets from the bottom to the top as you did for Port1. Follow the same procedure for Port3 and Port4. English - 48 - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 51
(5) Save the settings. (a) Click the "Send to HW" button (h). When the dialog box indicating that the process finished successfully is displayed, click OK. (b) Check that the image is correctly displayed, and then click the "Save" button (i). When the screen indicating that the process finished - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 52
Receiving card settings (1) The Screen Configuration screen is displayed. Select the "Receiving Card" tab (a). (a) (c) (b) (d) (2) Click "Load from File" (b). (3) Select the configuration file (rcfgx file) you want to load to the receiving card. A screen like the following appears when the - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 53
Update the Calibration Data (1) Login as Advanced User. (2) Click the "Calibration" button (a). Start calibration menu. (a) (3) Select the "Screen1" radio button. (4) Click on the "Manage Coefficients" tab (b). (b) English - 51 - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 54
(5) Click on "Module Flash". Result: The module flash options will appear. Select whether you want the entire screen or individual modules. Full screen: Select this option when installing. Module Flash (Select by Topology or list): Select this option when replacing pixel cards, etc. If "Line - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 55
(7) Click "Save Calibration Coefficients to Receiving Card". The pop-up message, that the data has been successfully stored to the Receiving cards, will appear. Result: The screen with the exchanged Pixel cards should look calibrated now. (8) Click on "Save to HW" button and go back to main window - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 56
Image Setting You can adjust the brightness, the gamma correction value, and the color temperature. Click "Brightness" on the top screen to display the following window. (b) (a) Click "Advanced Settings" to expand the screen. (c) (e) (d) English - 54 - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 57
Click "Advanced Settings" ( ) (a) to expand the setting screen. (1) Brightness Set the brightness of the screen using the slider (b). Increasing the value increases the brightness. (2) Gamma correction Set the gamma correction value using the slider (c). Increasing the value makes the dark parts of - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 58
Line calibration (1) Log in with the administrator privileges (English-44). (2) On the tabs at the top of the window, click Tools > Quickly Adjust Dark or Bright Lines > Adjust Dark or Bright Lines (3) Click the "Quickly Adjust (New)" button on the right of the window that pops up. (4) A screen like - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 59
(5) Click "Module Mode" on the top left of the screen. Enter the number of pixel cards inside one module on the screen that pops up, and then click "OK". Lines separating each pixel card are displayed. 8 pixel cards in 1 module English - 57 - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 60
(6) Specify the border between the pixel cards for which you want to perform line calibration by clicking on it or specifying a range. You may also adjust multiple locations at the same time. < Tool icons used to select the adjustment range > Clear effects: Resets the line calibration in the - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 61
(7) Click the upward and downward arrows next to the input box at the bottom of the window to adjust the brightness of the selected locations. Upward arrow: Increases the brightness (makes the dark lines less noticeable) Downward arrow: Decreases the brightness (makes the bright lines less - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 62
(9) The adjustment is complete when the following screen is displayed. Click "Close" to finish. English - 60 - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 63
Cleaning The screen brightness may decrease if dust or another foreign material is adhering to the surface of the pixel card. The magnet used to install the pixel cards also attracts magnetic metal particles, such as iron powder. Therefore, magnetic metal particles may adhere to areas near the - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 64
Maintenance CAUTION • Disconnect the power supply to the LED modules when performing the maintenance. • Before installing or removing pixel cards, please ensure the wall has been powered off for 1 or 2 hours. Otherwise the thermal expansion of pixel cards increases the risk of damaging them during - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 65
maintenance tool is fully charged before starting the work. Pixel card falls if the battery runs out. Hold the pixel card with your hand to support in case it falls. • Do not turn the maintenance tool off until you hold the pixel card. Otherwise, the pixel card may fall and break - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 66
Removing and installing the hub board (1) Removing the hub board (a) Disconnect the LAN cable from the hub board (b) Remove the 16 screws securing the hub board with a Phillips screwdriver (No. 1). (c) Since the hub board is connected to the power unit with pins and connectors, remove it by raising - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 67
(2) Installing the hub board Install the hub board into the cabinet following the procedure below. (a) Connect the status board to the hub board using the cable. (b) Install the hub board into the cabinet. Install it with the power unit pins and connectors aligned. Insert the pins and connectors - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 68
Remove the two screws securing the power unit. Use a Phillips screwdriver (No. 2). Replace the power unit. Use the screws you have removed to secure the power unit. Tightening torque: 3 ± 0.5 kgf•cm Replacing the receiving card Remove the receiving card from the hub board. Remove the four screws - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 69
Troubleshooting 1. Display problems Problem Nothing is displayed on all the LED modules. Nothing is displayed on one LED module. No image is displayed on one pixel card. Control (communication) - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 70
2. Adjusting the colors on a part of the screen (1) Log in with the administrator privileges (English-44). (2) Click "Calibration" (a). Start calibration menu. (a) (3) Check that "Chroma Calibration" (b) is selected and click the "Manage Coefficients" tab (c). (c) (b) English - 68 - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 71
(4) Set "Extended Display" (d) under "Setting of Displaying Image", and then click "Adjust coefficients" (e). (e) (d) (5) Select the range specification method from the three available methods depending on the calibration range. After setting the range, click "Next" to display the "Adjust - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 72
(5)-2 Select by Pixel Area: Adjust by pixels. The screen used to specify the adjustment range is displayed. Column Number: The position (pixel) on the horizontal axis of the starting point (top left) of the selection range Row Number: The position (pixel) on the vertical axis of the starting - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 73
Check that "Adjust Its Own Effect" is selected and click "Next" to start the calibration settings reading process. The "Adjust Coefficients" screen is displayed when the data has been read. (5)-3 Select by Topology or List: Adjust multiple modules A screen with the display configuration is displayed - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 74
(6) Adjust Coefficients screen Click "Advanced Adjustment". (7) Adjust the "Color adjustment of red, green and blue" parameters, and then adjust the "Color matching of red, green and blue" parameters. Click "Next" after you have finished the adjustment. English - 72 - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 75
(8) Click "Save" to save the calibration settings you have adjusted. (9) Click "Finish" to complete the procedure. Note To return the calibration adjustment values to their default setting, perform the "Update the Calibration Data" procedure (English-51). English - 73 - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 76
3. State monitoring using the software In case of a problem, you will be able to determine the location where it occurred by monitoring the state of the system. 3-1 Display under normal conditions The display is - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 77
with the input signal to the LED controller When the display is red, there is a problem with the LED controller. To display more details, click "Monitoring", and then click "Sending card" on the screen that is displayed. No video signal is - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 78
display more details, click "Monitoring", and then click "Receiving card" on the screen that is displayed. In the example shown on the left, the following problems must be considered. - Signal loss between the screen of the 3rd row 3rd column and the screen of the 2nd row 3rd column → Check the - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 79
with the internal temperature of the LED modules There is a problem with the LED module operation. To display more details, click "Monitoring", and then the brightness setting. If changing the brightness setting could not solve the problem, contact your retailer or the Customer Service. English - 77 - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 80
(4) Communication problem When the display is grey, the communication is not established. → Check that the USB cable is connected. → Check that the LED controller is turned on. English - 78 - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 81
4. Redundancy setting method 4.1 Configuring the settings with two LED controllers connected to the PC using LAN cables Connect the LED controllers and the LED modules with LAN cables. Terminate the Backup system connection at the RJ-45 connector located top left on the last module in the daisy - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 82
Check the port in "Select Communication Port", select the Main (Primary) and Backup system LED controllers by their IP address, and then click "Next". Configure the settings for the Main (Primary) controller and Backup controller separately. Main (Primary) Backup On the Main (Primary) side Click - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 83
use "Ethernet Port No." and the screen configuration section to configure the connection. * For details of the configuration procedure, refer to the User's Manual. Next, select the Sending Card tab. Go to "Redundancy", select the checkbox for "Set as Primary" and click "Save". On the Backup - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 84
Backup Select the Screen Connection tab. Configure the connection in the same way as for Main (Primary). * The direction of connection is the same as for Main (Primary). Next, select the Sending Card tab. Go to "Redundancy", select the checkbox for "Set as Backup" and click "Save". E (End) S (Start) - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 85
The monitoring screens appear like below. English - 83 - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 86
Note: On the monitoring screen, the LED modules configured as "Backup" are displayed in red color (this is not an indication of a fault). If a fault occurs on modules configured as "Main (Primary)", "Backup" modules are displayed in green color, which is an indication of normal state. "Main ( - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 87
In the case of MCTRL 4K, the display of the LED controllers is as follows. (This example display is for the case of connection using four Ethernet cables.) Upper: Backup Lower: Main (Primary) English - 85 - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 88
4.2 Configuring the settings with two LED controllers connected to the PC using USB cables Connect the LED controllers and the LED modules with LAN cables. Terminate the Backup system connection at the RJ-45 connector located top left on the last module in the daisy chain connection. LED modules - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 89
Select the port in "Select Communication Port", and then click "Next". In the Screen Configuration screen that is displayed, select the "Sending Card" tab. Click the "Restore Factory Settings" button for initialization. After initialization, configure the settings for "Select Input Source" and " - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 90
Port No." and the screen configuration section to configure the connection. * For details of the configuration procedure, refer to the User's Manual. Notes on the setting operation: Perform these setting procedures prior to the redundancy settings configuration. Make sure that the value of "Quantity - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 91
In the Redundancy Settings screen, set the Port number of the Backup side LED controller (Sending Card) that matches the Port number of the Primary side LED controller (Sending Card). After entering the value, click the "Add" button. In the LED configuration example (English-79), the settings are as - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 92
Check the current brightness setting. Click the "Brightness" button. In the Brightness Adjustment screen, set the desired brightness value and click the "Save to HW" button. The monitoring screens appear like below. English - 90 - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 93
In the case of MCTRL 4K, the display of the LED controllers is as follows. (This example display is for the case of connection using four Ethernet cables.) Upper: Backup Lower: Main (Primary) English - 91 - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 94
4.3 Configuring the settings with one LED controller connected to the PC using a USB cable Connect the LED controllers and the LED modules with LAN cables. Terminate the Backup system connection at the RJ-45 connector located top left on the last module in the daisy chain connection. LED modules - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 95
Select the port in "Select Communication Port", and then click "Next". Click the "Restore Factory Settings" button for initialization. After initialization, configure the settings for "Select Input Source" and "Source Configuration". If the factory setting is correctly configured and the device - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 96
Port No." and the screen configuration section to configure the connection. * For details of the configuration procedure, refer to the User's Manual. E (End) S (Start) Notes on the setting operation: Perform these setting procedures prior to the redundancy settings configuration. Make sure that the - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 97
In the Redundancy Settings screen, set the Port to use on the LED controller. In the LED configuration example (English-92), the settings are as follows. After entering the value, click the "Add" button. Serial Number of Primary Sending Card : 1 Serial Number of Primary Port : 1 Serial Number of - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 98
Check the current brightness setting. Click the "Brightness" button. In the Brightness Adjustment screen, set the desired brightness value and click the "Save to HW" button. The monitoring screens appear like below. English - 96 - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 99
Specifications Models for indoor use LED-FE012i3 LED-FE015i3 LED-FE019i3 LED configuration Pixel pitch Number of displayed pixels (resolution/module) Brightness Contrast ratio Brightness adjustment range Gamma correction Color temperature Viewing angle Signal interface Signal input - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 100
Models for indoor use LED-FE012i3-110 LED-FE015i3-137 LED-FE019i3-165 LED-FE012i3-220 Module configuration LED configuration Pixel pitch Number of displayed pixels (resolution/module) Brightness Contrast ratio Brightness adjustment range Gamma correction Color temperature Viewing angle - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 101
Diagram LED-FE012i3, LED-FE015i3, LED-FE019i3 608 49 342 Rear 4 x M8 18.5 24 294 24 44 520 44 (Unit: mm) English - 99 - Sharp LED-FE3 | Installation and Maintenance Manual - Series - Page 102
Adjustment plate 28 4-Φ8.5 75 75 10 (Unit: mm) English - 100
![](/manual_guide/products/sharp-ledfe3-installation-maintenance-manual-series-7e4e1ea/1.png)
Installation and
Maintenance manual
LED Module
[Models for indoor use]
LED-FE012i3
LED-FE015i3
LED-FE019i3
MODEL:
LED-FE012i3, LED-FE015i3, LED-FE019i3
LED Display Kit
[Models for indoor use]
LED-FE012i3-110
LED-FE015i3-137
LED-FE019i3-165
LED-FE012i3-220