Sharp PN-L805H Safety Standard FCC

Sharp PN-L805H Manual

Sharp PN-L805H manual content summary:

  • Sharp PN-L805H | Safety Standard FCC - Page 1
    Business Solutions BU 492 Minosho-Cho, Yamatokoriyama-Shi, Nara 639-1186, JAPAN 2. Type of Equipment: LCD Monitor 3. Model Number / Brand: PN-L805H/SHARP 4. Test Standard: FCC Part15 Subpart B (ANSI63.4:2014), ICES-003 Issue6:2016, Class A 5. Test Result: PASS Note 1. This test report shall
  • 1

Sharp Nara Test Center
Test Report No.: D17-0106-A1
Page:
1 / 62
Issued Date: 2018/03/16
Ver.2.2_2017/06/30
1. Customer/ Applicant:
Visual Solutions Business Unit
Business Solutions BU
(Address)
492 Minosho-Cho, Yamatokoriyama-Shi, Nara 639-1186, JAPAN
2. Type of Equipment:
LCD Monitor
3. Model Number / Brand:
PN-L805H/SHARP
4. Test Standard:
FCC Part15 Subpart B (ANSI63.4:2014), ICES-003 Issue6:2016, Class A
5. Test Result:
PASS
Note
1.
This test report shall not be reproduced in full or partial, without the written approval of Sharp Nara
Test Center.
(この試験報告書は、シャープ奈良試験センターの許可を得ることなしに複製してはならない。)
2.
The results in this report should not be construed to imply compliance of equipment other than that which
was tested.
(この試験報告書の結果は、試験された以外の機器の適合性を意味するものでない。)
3.
Measurement uncertainty in our test center is less than Ucispr specified in CISPR16-4-2, so this
measurement uncertainty is not considered into the judgment.
EMI only
(当試験センターの計測における
測定不確かさは、CISPR16-4-2 に示される Ucispr を下回るため、適合性の判定には考慮しない。〔EMI のみ〕)
4.
There is no test item of non-accreditation.
(非認定の試験項目はなし。)
Date of Test:
2018/03/01,03/05-07
Issued Date:
2018/03/16
EMI Tested by:
Approved by:
Keizoh Kitahashi
Technical Manager
(Sharp Nara Test Center)
EMS Tested by:
---------------------------------------
Sharp Nara Test Center
(シャープ奈良試験センター)
Telephone:
+81-743-55-5082
492 Minosho-Cho, Yamatokoriyama-Shi, Nara 639-1186, JAPAN
Facsimile:
+81-743-52-6894
[VCCI Acceptance No.: A-0183]
EMC Test Report
EMC
試験報告書)
Test Report Number: D17-0106-A1
yyyy/mm/dd
yyyy/mm/dd
Teruki Sugiura
< CERTIFIED COPY OF ORIGINAL DOCUMENT >