TP-Link TL-SG3428MP TL-SG3428XMPUN V1 Installation Guide
TP-Link TL-SG3428MP Manual
View all TP-Link TL-SG3428MP manuals
Add to My Manuals
Save this manual to your list of manuals |
TP-Link TL-SG3428MP manual content summary:
- TP-Link TL-SG3428MP | TL-SG3428XMPUN V1 Installation Guide - Page 1
Business Networking Solution Installation Guide JetStream L2/L2+ Managed Switch - TP-Link TL-SG3428MP | TL-SG3428XMPUN V1 Installation Guide - Page 2
- TP-Link TL-SG3428MP | TL-SG3428XMPUN V1 Installation Guide - Page 3
connection of the switch. Chapter 4 Configuration This chapter illustrates how to configure the switch. Appendix A Troubleshooting Appendix B Hardware Specifications Audience This Installation Guide is for: Network Engineer Network Administrator Conventions • Some models featured in this - TP-Link TL-SG3428MP | TL-SG3428XMPUN V1 Installation Guide - Page 4
12 3.3 Console Port 12 3.4 Verify Installation 13 3.5 Power On 14 3.6 Initialization 14 Chapter 4 Configuration----------- 15 4.1 Configuration Overview 15 4.2 Standalone Mode 15 4.3 Controller Mode 16 Appendix A Troubleshooting--------- 19 Appendix B Specifications---------- 20 - TP-Link TL-SG3428MP | TL-SG3428XMPUN V1 Installation Guide - Page 5
abundant L2 management features. It provides a variety of service features and multiple powerful functions with high security. The also a Power Sourcing Equipment (PSE*). All the RJ45 ports on the switch support Power over Ethernet (PoE*) function, which can automatically detect and supply power to - TP-Link TL-SG3428MP | TL-SG3428XMPUN V1 Installation Guide - Page 6
JetStream L2/L2+ Managed Switch The front panel of TL-SG3428 is shown as the following figure. Figure 1-3 Front Panel of TL-SG3428 LED Console Port (USB/RJ45) 1G RJ45 Port The front panel of TL-SG3428MP is shown as the following figure. Figure 1-4 Front Panel of TL-SG3428MP SFP Slot LED - TP-Link TL-SG3428MP | TL-SG3428XMPUN V1 Installation Guide - Page 7
JetStream L2/L2+ Managed Switch The front panel of TL-SG3452 is shown as the following figure. Figure 1-7 Front Panel of TL-SG3452 Console Port LED (USB/RJ45) 1G RJ45 Port F SFP Slot The front panel of TL-SG3452P is shown as the following figure. Figure 1-8 Front Panel of TL-SG3452P TL- - TP-Link TL-SG3428MP | TL-SG3428XMPUN V1 Installation Guide - Page 8
JetStream L2/L2+ Managed Switch LED Port 9-10 Indication Green On: Running at 10 Gbps, but no activity. Green Flashing: Running at 10 Gbps and transmitting or receiving data. Yellow On: Running at 1 Gbps, but no activity. Yellow Flashing: Running at 1 Gbps and transmitting or receiving data. Off: - TP-Link TL-SG3428MP | TL-SG3428XMPUN V1 Installation Guide - Page 9
JetStream L2/L2+ Managed Switch LED Port 25-28 Indication Green On: Running at 10 Gbps, but no activity. Green Flashing: Running at 10 Gbps and transmitting or receiving data. Yellow On: Running at 1 Gbps, but no activity. Yellow Flashing: Running at 1 Gbps and transmitting or receiving data. Off: - TP-Link TL-SG3428MP | TL-SG3428XMPUN V1 Installation Guide - Page 10
JetStream L2/L2+ Managed Switch LED SFP+ Indication Green On: Running at 10 Gbps, but no activity. Green Flashing: Running at 10 Gbps and transmitting or receiving data. Yellow On: Running at 1 Gbps, but no activity. Yellow Flashing: Running at 1 Gbps and transmitting or receiving data. Off: No - TP-Link TL-SG3428MP | TL-SG3428XMPUN V1 Installation Guide - Page 11
, search the model number of your switch and go to the product Support web page, refer to the Lightning Protection Guide from the Related Documents: https://www.tp-link.com/us/configuration-guides/lightning_protection_guide/. Power Socket Connect the female connector of the power cord here, and - TP-Link TL-SG3428MP | TL-SG3428XMPUN V1 Installation Guide - Page 12
, if any of the listed items is damaged or missing. One Switch One Power Cord and One Console Cable Installation Guide Business Networking Solution Installation Guide Two Mounting Brackets, Eight Screws and Four Rubber Feet 2.2 Safety Precautions To avoid any device damage and bodily injury - TP-Link TL-SG3428MP | TL-SG3428XMPUN V1 Installation Guide - Page 13
, leakage of electricity, mechanical property changes, and corrosion. High temperatures may accelerate aging of the insulation materials, significantly shortening the service life of the device. To find out the best temperature and humidity conditions for the device, check the following table - TP-Link TL-SG3428MP | TL-SG3428XMPUN V1 Installation Guide - Page 14
, search the model number of your switch and go to the product Support web page, refer to the Lightning Protection Guide from the Related Documents: https://www.tp-link.com/us/configuration-guides/lightning_protection_guide/. Installation Site When installing the device on a rack or a flat workbench - TP-Link TL-SG3428MP | TL-SG3428XMPUN V1 Installation Guide - Page 15
Switch Feet Bottom of the Device Notch ■■ Rack Installation To install the device in an EIA standard-sized, 19-inch rack, follow the instructions described below: 1. Check the efficiency of the grounding system and the stability of the rack. 2. Secure the supplied rack-mounting brackets to each - TP-Link TL-SG3428MP | TL-SG3428XMPUN V1 Installation Guide - Page 16
JetStream L2/L2+ Managed Switch Chapter 3 Connection 3.1 Ethernet Port Connect an Ethernet port of the switch to the computer by RJ45 cable as the following figure shows. Figure 3-1 Connecting the RJ45 Port RJ45 Port RJ45 Cable 3.2 SFP/SFP+ Slot The following figure demonstrates the - TP-Link TL-SG3428MP | TL-SG3428XMPUN V1 Installation Guide - Page 17
JetStream L2/L2+ Managed Switch Connect the console (RJ45) port of the device with your computer by the console cable as the following figure shows. Figure 3-3 Connecting the Console (RJ45) Port Connect the console (USB) port of the device with your computer by the USB cable (not provided) as - TP-Link TL-SG3428MP | TL-SG3428XMPUN V1 Installation Guide - Page 18
JetStream L2/L2+ Managed Switch 3.5 Power On Plug the female connector of the provided power cord into the power socket of the device and plug the positive connector into a power outlet as the following figure shows. Make sure that the voltage of the power supply meets the requirement of the input - TP-Link TL-SG3428MP | TL-SG3428XMPUN V1 Installation Guide - Page 19
to configure the corresponding functions. For the detailed configurations, refer to the User Guide and CLI Guide. The guides can be found on the download center of our official website: https://www.tp-link.com/support/download/. ■■ Using the CLI ■■ Set up a Telnet or SSH connection to access the - TP-Link TL-SG3428MP | TL-SG3428XMPUN V1 Installation Guide - Page 20
as follows: Baud Rate 38400 bps Data Bits 8 Parity None Stop Bits 1 Flow Control None For the detailed configurations, refer to the User Guide and CLI Guide. The guides can be found on the download center of our official website: https://www.tp-link.com/download-center.html Note: For certain - TP-Link TL-SG3428MP | TL-SG3428XMPUN V1 Installation Guide - Page 21
installation file from https://www.tp-link.com/support/download/omada-software-controller/. 2. Run the Omada Software Controller and follow the step-by-step instructions to complete the Quick Setup. After the wizard is the Installation Guide of Omada Hardware Controller. * Omada Cloud Service After - TP-Link TL-SG3428MP | TL-SG3428XMPUN V1 Installation Guide - Page 22
Cloud-Based Controller. Follow the instructions to choose a plan and complete and follow the step-by-step instructions to complete the Quick Setup. After can add devices to the controller manually through the serial numbers at the Guide of the controller. The guide can be found on the download - TP-Link TL-SG3428MP | TL-SG3428XMPUN V1 Installation Guide - Page 23
Appendix A Troubleshooting Q1. What could I do if I forgot the username and password of the switch? 1. Connect the console port of the PC to the console port of - TP-Link TL-SG3428MP | TL-SG3428XMPUN V1 Installation Guide - Page 24
Appendix B Specifications Item Standards Content IEEE 802.3, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3ad, IEEE 802.3z, IEEE 802.3x, IEEE 802.1p, IEEE 802.1q, IEEE 802.1x, IEEE 802.1d, IEEE 802.1s, IEEE 802.1w, IEEE 802.1ab IEEE 802.3af/at (For TL-SG3210XHP-M2, TL-SG3428MP, TL-SG3428XMP, TL-SG3452P) - TP-Link TL-SG3428MP | TL-SG3428XMPUN V1 Installation Guide - Page 25
Operating Temperature 0 ℃ to 40 ℃ (32 °F to 104 °F) Storage Temperature -40 ℃ to 70 ℃ (-40 °F to 158 °F) Operating Humidity 10% to 90% RH Non-condensing Storage Humidity 5% to 90% RH Non-condensing - TP-Link TL-SG3428MP | TL-SG3428XMPUN V1 Installation Guide - Page 26
• Keep the device away from water, fire, humidity or hot environments. • Do not attempt to disassemble, repair, or modify the device.If you need service, please contact us. • Place the device with its bottom surface downward. • The plug on the power supply cord is used as the disconnect device, the - TP-Link TL-SG3428MP | TL-SG3428XMPUN V1 Installation Guide - Page 27
- TP-Link TL-SG3428MP | TL-SG3428XMPUN V1 Installation Guide - Page 28
with TP-Link users or engineers, please visit https://community.tp-link.com to join TP-Link Community. For technical support, the user guide and other information, please visit https://www.tp-link.com/support, or simply scan the QR code. If you have any suggestions or needs on the product
Business Networking Solution
Installation Guide
JetStream L2/L2+ Managed Switch