Vaddio RoboSHOT 30 RoboSHOT 12 and 30 QCCU System Manual

Vaddio RoboSHOT 30 Manual

Vaddio RoboSHOT 30 manual content summary:

  • Vaddio RoboSHOT 30 | RoboSHOT 12 and 30 QCCU System Manual - Page 1
    Installation and User Guide VADDIO™ ROBOSHOT™ SERIES CAMERAS RoboSHOT 12 and RoboSHOT 30, HD Robotic PTZ Camera Systems featuring the Quick-Connect™ Universal CCU Interface RoboSHOT 12 High-definition Robotic PTZ Conferencing Camera Featuring a 12X, 73º Wide Angle Optical Zoom Lens and Tri-
  • Vaddio RoboSHOT 30 | RoboSHOT 12 and 30 QCCU System Manual - Page 2
    RoboSHOT HD Cameras Inside Front Cover - Blank RoboSHOT HD Cameras - Document Number 342-0797 Rev A Page 2 of 48
  • Vaddio RoboSHOT 30 | RoboSHOT 12 and 30 QCCU System Manual - Page 3
    the Camera Systems ...6 Image: RoboSHOT 12 HD PTZ Camera ...7 Image: RoboSHOT 30 HD PTZ Camera ...8 Image: RoboSHOT 12X and 30X Rear Panel Connections 9 Rear panel connections are identical for both models (RoboSHOT 12 shown 9 Anatomy of the Universal CCU ...10 Image: Front Panel CCU Controls
  • Vaddio RoboSHOT 30 | RoboSHOT 12 and 30 QCCU System Manual - Page 4
    view and provides exceptional support for applications including House of Worship productions, large auditorium A/V systems, large distance learning classrooms, live event theatres with IMAG systems, large lecture theatres with lecture capture and more! RoboSHOT 12 HD PTZ Camera on Mount The key
  • Vaddio RoboSHOT 30 | RoboSHOT 12 and 30 QCCU System Manual - Page 5
    and pairs 4 & 5), the Vaddio EZCamera systems use all of the pins in most configurations. When terminated correctly The Vaddio Cat-5e solution provides for the utmost in flexibility for HD video system design, integration and ease of installation. RoboSHOT HD Cameras - Document Number 342-0797 Rev
  • Vaddio RoboSHOT 30 | RoboSHOT 12 and 30 QCCU System Manual - Page 6
    806-819 Gray RJ-45 Dust Cap (for 36VDC RJ-45 Port on camera) One (1) 3-pin Molex 5.0mm Euro style Connector One (1) Quick Setup Guide RoboSHOT 30 QCCU System Part Number 999-9907-001 (International) One (1) RoboSHOT 12 HD PTZ Camera (998-9900-000) One (1) Thin Profile Wall Mount (535-2000-240) with
  • Vaddio RoboSHOT 30 | RoboSHOT 12 and 30 QCCU System Manual - Page 7
    RoboSHOT HD Cameras Image: RoboSHOT 12 HD PTZ Camera Camera Front View with Feature Call-outs ① ② ③ ④ Color: Silver and Black ⑤ ⑥ 1) Camera and Zoom Lens: This RoboSHOT precise HD video image acquisition in a small to medium sized conference room. 2) Camera Support Arm: The RoboSHOT cameras use
  • Vaddio RoboSHOT 30 | RoboSHOT 12 and 30 QCCU System Manual - Page 8
    Exmor 1/2.8-Typ, high-speed, low noise image sensor with a total of 2.34 megapixels for vibrant, detailed HD video image acquisition in a large to medium sized room. 2) Camera Support Arm: The RoboSHOT cameras use a single control arm for pan and tilt movements. Both ends of the cast control arm are
  • Vaddio RoboSHOT 30 | RoboSHOT 12 and 30 QCCU System Manual - Page 9
    the RS-232 connects normally. Please see the system diagrams of the CCU systems to fully understand the wiring. NOTE: Remove the dust cap just prior to connecting the 36 VDC Cat-5e cable. Please do not plug this cable into the EZ-POWER VIDEO RJ-45. RoboSHOT HD Cameras - Document Number 342-0797 Rev
  • Vaddio RoboSHOT 30 | RoboSHOT 12 and 30 QCCU System Manual - Page 10
    RoboSHOT HD Cameras ANATOMY OF THE UNIVERSAL CCU The Universal CCU will automatically sense the connected camera and initialize the firmware for that camera. The next section will look at the controls and how they are laid out for easy access. Image: Front Panel CCU available. To manually adjust the
  • Vaddio RoboSHOT 30 | RoboSHOT 12 and 30 QCCU System Manual - Page 11
    )  HDMI on HDMI-F (supports up to and including 1080p/60)  HD-SDI on Edge Mount Carrier Class, Gold BNC-F (supports 3Gb/s Single Link 1080p/60 HD-SDI) The Quick-Connect Universal CCU supports the resolutions with refresh rates of above 50 Hz (60, 59.94 and 50). RoboSHOT HD Cameras - Document
  • Vaddio RoboSHOT 30 | RoboSHOT 12 and 30 QCCU System Manual - Page 12
    RoboSHOT HD Cameras ROBOSHOT AND QUICK-CONNECT UNIVERSAL CCU CONTROL MENUS The RoboSHOT cameras have individual firmware that auto loads when the camera is plugged in to the Universal CCU and the CCU is turned on (Note: Always turn the camera on first so when the CCU wakes up, it will recognize the
  • Vaddio RoboSHOT 30 | RoboSHOT 12 and 30 QCCU System Manual - Page 13
    ' (152.4m) in length Cat-5e Power to Camera ► RS-232 Cat-5e ◄ Cat-5e Video to CCU Quick-Connect Universal CCU (Rear Panel) RS-232 HDMI HD-SDI Simulated Video Feeds ProductionVIEW HD-SDI MV with built-in Multi-viewer RoboSHOT HD Cameras - Document Number 342-0797 Rev A Multi-viewer Preview
  • Vaddio RoboSHOT 30 | RoboSHOT 12 and 30 QCCU System Manual - Page 14
    move to the home position. The CCU will find the camera and load the RoboSHOT control protocols. If using a Vaddio controller, connect it to the RS-232 IN RJ-45 and turn on the controller. To ensure proper continuity of control, the RS-232 controller (control system or joystick) should be powered on
  • Vaddio RoboSHOT 30 | RoboSHOT 12 and 30 QCCU System Manual - Page 15
    When using RS-232 control or Vaddio CCU controllers (also via RS-232), turn the IR OUT to OFF (up).  Image Flip (SW4): To invert the camera, turn the IMAGE FLIP ON (switch down).  Super-Wide Mode: Super-wide works only with the RoboSHOT 12 model and allows the camera to switch from 67.3º wide end
  • Vaddio RoboSHOT 30 | RoboSHOT 12 and 30 QCCU System Manual - Page 16
    (gets/sets streaming resolution)  Streaming (gets/sets current streaming settings)  System Factory Reset  System Reboot  Version (system version information) *Please see the full Telnet command list at the end of this manual RoboSHOT HD Cameras - Document Number 342-0797 Rev A Page 16 of 48
  • Vaddio RoboSHOT 30 | RoboSHOT 12 and 30 QCCU System Manual - Page 17
    password If a user or an admin logs in through this screen, then the next page shown will be the camera control page. The user will only have access to the camera control page. The Admin will have complete access to all web pages. RoboSHOT HD Cameras - Document Number 342-0797 Rev A Page 17 of 48
  • Vaddio RoboSHOT 30 | RoboSHOT 12 and 30 QCCU System Manual - Page 18
    in low power mode and effectively puts the RoboSHOT to sleep. The camera will pan 90º from center and 30º downward (to not collect dust on the lens). When the camera is inverted (ceiling mounted) the camera will pan 90º from center and 30º downward. If the system is on, then the button will be
  • Vaddio RoboSHOT 30 | RoboSHOT 12 and 30 QCCU System Manual - Page 19
    camera shot, click one of the Preset buttons (1 through 12), the button will be highlighted and the dialog box will present the Tri-Sync controls and if the CCU currently assigned CCU scenes settings, check this box. 4) Click Save or Cancel to exit this pop-up dialog box. RoboSHOT HD Cameras -
  • Vaddio RoboSHOT 30 | RoboSHOT 12 and 30 QCCU System Manual - Page 20
    automatic guest access to the main camera control page. I f guest access is turned on by the Admin, then system will open to the camera control page and an additional Admin Login is provided. The default Admin password is: password. Admin RoboSHOT HD Cameras - Document Number 342-0797 Rev A Page
  • Vaddio RoboSHOT 30 | RoboSHOT 12 and 30 QCCU System Manual - Page 21
    section are defined below (top to bottom):  Auto Iris Check Box: When checked, the camera will operate in Auto Iris mode, when unchecked, the camera will be in Manual Iris mode and allow adjustment of Iris and Iris Gain levels. RoboSHOT HD Cameras - Document Number 342-0797 Rev A Page 21 of 48
  • Vaddio RoboSHOT 30 | RoboSHOT 12 and 30 QCCU System Manual - Page 22
    camera will operate in Auto White Balance mode, when unchecked camera will be in Manual of the slider. 5) Store CCU Scene button: Once the desired RoboSHOT basis. The labels appear on every page at the top/middle of the page. Simply enter the room information and click Save. RoboSHOT HD Cameras
  • Vaddio RoboSHOT 30 | RoboSHOT 12 and 30 QCCU System Manual - Page 23
    RoboSHOT HD Cameras Screen Shot: Admin Menu - DHCP Network Configuration Under the Networking menu, If Static IP is used, the IP Address, Subnet Mask and Gateway are manually entered. Click on Save to keep the Static IP information. RoboSHOT HD Cameras - Document Number 342-0797 Rev A Page 23 of 48
  • Vaddio RoboSHOT 30 | RoboSHOT 12 and 30 QCCU System Manual - Page 24
    Access" box is checked. Screen Shot: Admin Menu - Diagnostics Diagnostics menu button will display a set of self-diagnostics. These diagnostics may help the Vaddio technical support team diagnose a problem with the RoboSHOT camera. RoboSHOT HD Cameras - Document Number 342-0797 Rev A Page 24 of 48
  • Vaddio RoboSHOT 30 | RoboSHOT 12 and 30 QCCU System Manual - Page 25
    RoboSHOT HD Cameras Screen Shot: Admin Menu - System The System Menu is where the System Info is displayed and Firmware Updates are performed. There will be firmware updates and upgrades over the life of the camera. The file for the firmware update is chosen in this menu and the update is started
  • Vaddio RoboSHOT 30 | RoboSHOT 12 and 30 QCCU System Manual - Page 26
    RoboSHOT HD Cameras Screen Shot: Admin Menu - Update Confirmation After choosing an update file and clicking on "Begin Firmware Update..." a confirmation pop-up and warning will be displayed. Please contact Vaddio Tech support for assistance with updates. Please read and completely understand the
  • Vaddio RoboSHOT 30 | RoboSHOT 12 and 30 QCCU System Manual - Page 27
    RoboSHOT HD Cameras Screen Shot - Admin Menu - Help Service/Help information can be found under the Help menu. Support phone numbers and e-mail, manuals, FAQ's and System information is listed on [email protected]. TECHNICAL SUPPORT NOTE: Please work with your Network Administrator prior to
  • Vaddio RoboSHOT 30 | RoboSHOT 12 and 30 QCCU System Manual - Page 28
    RoboSHOT HD Cameras GENERAL SPECIFICATIONS RoboSHOT Cameras Part Numbers Image Device Video Resolution/Frequencies Vaddio Special Features Video Aspect Ratio Effective Pixels RoboSHOT 12 Lens and Horizontal FOV Description RoboSHOT 12 QCCU System, 999-9907-000 (North America), 999-9907-001 (Int
  • Vaddio RoboSHOT 30 | RoboSHOT 12 and 30 QCCU System Manual - Page 29
    of red gain pq=Red gain (00h - FFh) Manual control of blue gain pq=Blue gain (00h - FFh) Auto Exposure mode Manual Control mode Shutter Priority Auto Exposure mode Iris Priority Auto Exposure Mode Bright Mode (modified AE mode) RoboSHOT HD Cameras - Document Number 342-0797 Rev A Page 29 of
  • Vaddio RoboSHOT 30 | RoboSHOT 12 and 30 QCCU System Manual - Page 30
    8x 01 04 3F 31 0p 0q 0r FF 8x 01 04 3F 02 0p FF 8x 01 04 3F 12 0p 0q 0r FF Comments Shutter Setting pq=Shutter Position (00h - 15h) Shutter Setting pq=Iris Position ** ID (0h-ffffh) p= preset number(0-0x0f) qr= Speed(0x01-0xff) RoboSHOT HD Cameras - Document Number 342-0797 Rev A Page 30 of 48
  • Vaddio RoboSHOT 30 | RoboSHOT 12 and 30 QCCU System Manual - Page 31
    degrees) s: Polarity offset (0 is plus, 1 is minus) tu: Offset s=0 (00h to 40h) RoboSHOT 12 (00h to 10h), RoboSHOT 30 (00 to 40h) vv= Pan speed ww=Tilt speed vv= Pan speed ww=Tilt speed position pp:pan, qq:tilt, rr:zoom speeds RoboSHOT HD Cameras - Document Number 342-0797 Rev A Page 31 of 48
  • Vaddio RoboSHOT 30 | RoboSHOT 12 and 30 QCCU System Manual - Page 32
    y0 50 0p FF Comments On Off (Standby) pqrs: Zoom Position Auto Focus Manual Focus pqrs: Focus Position pqrs: Focus Near Limit Position AF Sensitivity Normal AF Gain On Off Noise Reduction p: 00h to 05h Gamma p: 00h , 01h RoboSHOT HD Cameras - Document Number 342-0797 Rev A Page 32 of 48
  • Vaddio RoboSHOT 30 | RoboSHOT 12 and 30 QCCU System Manual - Page 33
    ccu, 01-trisync,11-trisyc /w ccu) rs: speed (0x1-0x18) 1 - 24 X: 00h to 07h (Address) pqrs: 0000h to FFFFh (Data) On Off On Off pqrs: Camera ID mnpq: Model Code RoboSHOT-12 RoboSHOT- 00h to 10h) wwww= Pan position zzzz=Tilt Position RoboSHOT HD Cameras - Document Number 342-0797 Rev A Page 33 of 48
  • Vaddio RoboSHOT 30 | RoboSHOT 12 and 30 QCCU System Manual - Page 34
    RoboSHOT HD Cameras TELNET SERIAL COMMAND API The Vaddio Serial Command protocol is a high level text based command line interface supported via telnet session on the RoboSHOT. The command application protocol interface is intended to allow external device such as AMX or Crestron to control the
  • Vaddio RoboSHOT 30 | RoboSHOT 12 and 30 QCCU System Manual - Page 35
    integer from 1-7 that represents the speed (Default: 3)  EXAMPLES camera zoom in Zooms the camera in at the default speed camera zoom out 7 Zooms the camera out using a speed of 7 camera zoom stop Stops the zoom movement of the camera RoboSHOT HD Cameras - Document Number 342-0797 Rev A Page 35 of
  • Vaddio RoboSHOT 30 | RoboSHOT 12 and 30 QCCU System Manual - Page 36
    iris Gets auto-iris mode iris Gets iris value gain gain Gets gain value detail detail Gets detail value chroma chroma Gets chroma value  EXAMPLES camera ccu get iris Gets the iris value camera ccu get red_gain Gets the red_gain RoboSHOT HD Cameras - Document Number 342-0797 Rev A Page 36 of 48
  • Vaddio RoboSHOT 30 | RoboSHOT 12 and 30 QCCU System Manual - Page 37
    RoboSHOT Camera Systems CCU Camera Scene  NAME camera ccu scene - Stores or recalls the ccu scene  SYNOPSIS camera ccu scene {recall {factory [1-6]|custom [1-3]} | store [1-3]}  DESCRIPTION Method used to get or set the ccu scene  OPTIONS recall Recalls a ccu scene store Stores a custom ccu
  • Vaddio RoboSHOT 30 | RoboSHOT 12 and 30 QCCU System Manual - Page 38
    RoboSHOT Camera Systems Camera CCU  NAME camera ccu - Stores and recalls scenes and gets and sets CCU settings  SYNOPSIS camera ccu  DESCRIPTION Method used to get or set the ccu scene or ccu setting  OPTIONS scene Used for storing/recalling scenes get Used for getting CCU settings set Used for
  • Vaddio RoboSHOT 30 | RoboSHOT 12 and 30 QCCU System Manual - Page 39
    RoboSHOT Camera Systems Exit  NAME exit - ends the current down in the command history.  HISTORY EXPANSION The command history supports the expansion functionality from which previous commands can be recalled from host at 192.168.1.1 RoboSHOT HD Cameras, Document Number 342-0797 Page 39 of 48
  • Vaddio RoboSHOT 30 | RoboSHOT 12 and 30 QCCU System Manual - Page 40
    RoboSHOT Camera Systems Network Settings  NAME network settings - get current network settings  SYNOPSIS network settings {get}  DESCRIPTION Method used ---network ping count 1 10.10.10.100 Pings 10.10.10.100 once and displays results RoboSHOT HD Cameras, Document Number 342-0797 Page 40 of 48
  • Vaddio RoboSHOT 30 | RoboSHOT 12 and 30 QCCU System Manual - Page 41
    System Reboot  NAME system reboot - Reboots system  SYNOPSIS system reboot []  DESCRIPTION Method used to reboot system  OPTIONS seconds The number of seconds to delay the reboot  EXAMPLES reboot Reboot system immediately reboot 30 Reboot the system in 30 seconds RoboSHOT HD Cameras
  • Vaddio RoboSHOT 30 | RoboSHOT 12 and 30 QCCU System Manual - Page 42
    Update the system using the update file Version  NAME version - display the system version information  SYNOPSIS version  DESCRIPTION Display an overview of the command line syntax  EXAMPLES Version Returns the current software version RoboSHOT HD Cameras, Document Number 342-0797
  • Vaddio RoboSHOT 30 | RoboSHOT 12 and 30 QCCU System Manual - Page 43
    RoboSHOT Camera Systems COMPLIANCE AND CE DECLARATION OF CONFORMITY - ROBOSHOT HD PTZ CAMERAS Compliance testing was performed to and used in accordance with the instruction manual, may cause harmful interference to modifications not expressly approved by Vaddio can affect emission compliance and
  • Vaddio RoboSHOT 30 | RoboSHOT 12 and 30 QCCU System Manual - Page 44
    RoboSHOT Camera Systems COMPLIANCE AND CE DECLARATION OF CONFORMITY - QUICK-CONNECT UNIVERSAL CCU Compliance testing was used in accordance with the instruction manual, may cause harmful interference to not expressly approved by Vaddio can affect emission compliance RoboSHOT HD Cameras, Document Number
  • Vaddio RoboSHOT 30 | RoboSHOT 12 and 30 QCCU System Manual - Page 45
    RoboSHOT Camera Systems WARRANTY INFORMATION (See Vaddio Warranty, Service and Return Policies posted on vaddio.com for complete details): Hardware* Warranty: Two (2) year limited warranty on all parts and labor for Vaddio manufactured products. Vaddio warrants its manufactured products against
  • Vaddio RoboSHOT 30 | RoboSHOT 12 and 30 QCCU System Manual - Page 46
    RoboSHOT Camera Systems APPENDIX 1: CABLE PIN-OUTS FOR THE QUICK-CONNECT CCU SYSTEM Quick-Connect CCU Pin-out Assignments: Power Connector RJ-45 (Red) Pin # Function Pin - CAMERA 12345678 RS-232 IN 12345678 RS-232 OUT 12345678 VIDEO FROM CAMERA 12345678 RoboSHOT HD Cameras, Document Number 342-0797 Page
  • Vaddio RoboSHOT 30 | RoboSHOT 12 and 30 QCCU System Manual - Page 47
    RoboSHOT Camera Systems Inside Back Cover - Mostly Blank RoboSHOT HD Cameras, Document Number 342-0797 Page 47 of 48
  • Vaddio RoboSHOT 30 | RoboSHOT 12 and 30 QCCU System Manual - Page 48
    RoboSHOT Camera Systems Toll Free: 800-572-2011 ▪ Phone: 763-971-4400 ▪ FAX: 763-971-4464 www.vaddio.com ©2014 Vaddio - All Rights Reserved. Reproduction in whole or in part without written permission is prohibited. Specifications and pricing are subject to change without notice or obligation.
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

© 2014 Vaddio - All Rights Reserved.
RoboSHOT QCCU Systems - Document Number 342-0797 Rev A
V
ADDIO
R
OBO
SHOT™
S
ERIES
C
AMERAS
RoboSHOT 12 and RoboSHOT 30, HD Robotic PTZ Camera Systems
featuring the Quick-Connect™ Universal CCU Interface
System Model and Part Numbers
RoboSHOT 12 QCCU System, 999-9907-000 (North America), 999-9907-001 (Int’l)
RoboSHOT 30 QCCU System, 999-9917-000 (North America), 999-9917-001 (Int’l)
RoboSHOT 30 QCCU System, 999-9917-000W (North America), 999-9917-001W (Int’l)
(Note:
The W suffix on the part number indicates white version of the RoboSHOT 30)
RoboSHOT 30
High-definition Robotic PTZ Camera for Medium to Large Venues
Featuring 30X Optical Zoom Lens and Tri-Synchronous Motion
RoboSHOT 12
High-definition Robotic PTZ Conferencing Camera Featuring a 12X,
73º Wide Angle Optical Zoom Lens and Tri-Synchronous Motion
Quick-Connect Universal CCU System Interface
Installation and User Guide