Viking DIPR150RSS Installation Instructions

Viking DIPR150RSS Manual

Viking DIPR150RSS manual content summary:

  • Viking DIPR150RSS | Installation Instructions - Page 1
    VIKING RANGE CORPORATION Designer Series Downdraft Ventilators MODEL WIDTH BLOWER (purchase separately) DIPR100R DIPR16OR DIPR15OR 30" w/ remote control 36" w/ remote control 45 THESE INSTRUCTIONS A directly behind appliance unless specifically recommended in this manual. All other servicing
  • Viking DIPR150RSS | Installation Instructions - Page 2
    VIKING RANGE cooktop. Note: the high level of airflow of this appliance may effect the gas flame on some types of gas 1. Refer to the cooktop installation instructions for dimensions of cooktop, countertop cut " wide cabinets, and the Model DIPR150RSS will fit most 45" wide cabinets. However, it is
  • Viking DIPR150RSS | Installation Instructions - Page 3
    VIKING RANGE CORPORATION Designer Series Downdraft Ventilators TAKE MEASUREMENTS (CONTINUED) Interior Blower Installation I 10" ductwork (can be transitioned to 6" round). Three 1 different discharge directions are available with side-to- side adjustment for accurate alignment of ductwork.
  • Viking DIPR150RSS | Installation Instructions - Page 4
    VIKING RANGE CORPORATION Designer Series Downdraft Ventilators PLAN THE CABINET CUTOUTS Interior Blower Installation I Exterior Blower Installation I LEFT SIDE DISCHARGE CENTER LINES OF DUCT CUTOUT 1014" x 312/ "
  • Viking DIPR150RSS | Installation Instructions - Page 5
    VIKING RANGE being installed in a 36" wide cabinet... or Model DIPR150RSS is being installed in a 45" wide cabinet... ...the outlet cannot be located on of the downdraft with the 3W x10" discharge pointed in the desired direction. 5. Connect motor plug. 6. Replace the gear motor cover and 2
  • Viking DIPR150RSS | Installation Instructions - Page 6
    VIKING RANGE CORPORATION Designer Series Downdraft Ventilators PREPARE THE 30" DGCU105 30" DGSU100 30" DGRT DIPR100RSS 36" DECU165 36" DGCU165 36" DGSU160 36" DGRT DIPR160RSS 45" DECU155 45" DGCU155 DIPR150RSS Cutout Dimensions A B C D E F 29-1/8" 20-5/8" 27" 2-1/4" 1-1/16" 1-1/16" C J
  • Viking DIPR150RSS | Installation Instructions - Page 7
    VIKING RANGE CORPORATION Designer Series Downdraft Ventilators MOUNT THE UNIT All Units 1. Set downdraft into opening. Extend leveling brackets to to rivet the ductwork to the unit. This will allow blower to be removed and replaced easily in service situations without disturbing ductwork. 7
  • Viking DIPR150RSS | Installation Instructions - Page 8
    VIKING RANGE CORPORATION Designer Series Downdraft Ventilators INSTALL ELECTRICAL WIRING I Interior Blower Installation A CAUTION: All electrical wiring should be done by a qualified person(s) in accordance with all
  • Viking DIPR150RSS | Installation Instructions - Page 9
    VIKING RANGE CORPORATION Designer Series Downdraft Ventilators INSTALLATION OF REMOTE CONTROL SWITCH ® WARNING: To reduce the risk of burns or ignition of clothing by reaching across burners,
  • Viking DIPR150RSS | Installation Instructions - Page 10
    VIKING RANGE CORPORATION Designer Series Downdraft Ventilators This page has been left blank intentionally. BACKSIDE OF REMOTE SWITCH TEMPLATE 10
  • Viking DIPR150RSS | Installation Instructions - Page 11
    VIKING RANGE CORPORATION Designer Series Downdraft Ventilators OPERATION UP / DOWN --- Raises It may be necessary to remove the downdraft blower system from Cleaning the cabinet in order to service components such as the blower motor or air vent mechanism. Use a mild detergent suitable for
  • Viking DIPR150RSS | Installation Instructions - Page 12
    Viking ventilation products as a direct result of the use of such equipment is not covered under the Viking making the appliance reasonably accessible for service. If service, contact the dealer from whom the product was purchased, an authorized Viking Range Corporation service agent, or Viking Range
  • Viking DIPR150RSS | Installation Instructions - Page 13
    VIKING RANGE CORPORATION Ventilateurs series de createur encastres de conception MODELE LARGEUR CES INSTRUCTIONS A DESTINE A LA CUISINE DOMESTIQUE SEULEMENT AVERTISSEMENT A e Li AVERTISSEMENT O AFIN DE DIMINUER LES RISQUES D'INCENDIE, D'ELECTROCUTION OU DE BLESSURES, SUIVEZ CES DIRECTIVES:
  • Viking DIPR150RSS | Installation Instructions - Page 14
    VIKING RANGE la soufflerie. Tous les appareils 1. Consultez les instructions d'installation pour connaitre les dimensions dela surface decuisson,du et le modele DIPR15ORSS dans la plupart des armoires de 114,3 cm (45 po) de largeur. II est cependant recommande d'utiliser des armoires plus grandes
  • Viking DIPR150RSS | Installation Instructions - Page 15
    VIKING RANGE CM (35/8 po) 12.7 cm (5 Pc) VIENRATEUR 45,7 cm liTtlEuR (18130) VIN560 (114 po 5.4 cm (2 (10 po) (pour connexion au ventilateur exterieur VEDV900 ou VEDV1200 (DIPR150RSS seulement)) 0.95 cm 19,5 cm (7 11/16 po) (3/8 /6 po). II existe trois directions possibles pour la sortie avec
  • Viking DIPR150RSS | Installation Instructions - Page 16
    VIKING RANGE CORPORATION Ventilateurs series de createur encastres de conception PREPARATION DU DECOUPAGE DE L'ARMOIRE Installation du ventilateur interieur Installation du ventilateur exterieurl SORTIE GAUCHE LIGNES DE
  • Viking DIPR150RSS | Installation Instructions - Page 17
    VIKING RANGE cm (36 po) de largeur... ou le modele DIPR150RSS est installe dans une armoire de 114,3 cm (45 po) de largeur... ...la prise ne peut pas la sortie de 8,3 x 25,4 cm (3-1/4 x 10 po) tournee dans la direction souhaitee. 5. Branchez Ia prise du moteur. 6. Replacez le couvercle du moteur et
  • Viking DIPR150RSS | Installation Instructions - Page 18
    VIKING RANGE CORPORATION Ventilateursseriesdecreateurencastre'sdeconception PREPARATION DE (36 po) DGCU165 91.4 cm (36 po) DGSU160 91.4 cm (36 po) DGRT DIPR160RSS 114.3 cm (45 po) DECU155 114.3 cm (45 po) DGCU155 DIPR150RSS 88.6 cm (34-7/8 po) 52.4 cm (20-5/8 po) 83.8 cm (33 po) 5.7 cm (2-1/4 po
  • Viking DIPR150RSS | Installation Instructions - Page 19
    VIKING RANGE CORPORATION Ventilateurs series de createur encastres de conception INSTALLATION DE L'UNITE Tous les modeles 1. Placez la hotte dans I'ouverture. Allongez les brides de nivellement jusqu'
  • Viking DIPR150RSS | Installation Instructions - Page 20
    VIKING RANGE CORPORATION Ventilateurs series de createur encastres de conception CABLAGE ELECTRIQUE installation du ventilateur interieur A ATTENTION : Le cablage doit etre effectue par un electricien qualifie conformement
  • Viking DIPR150RSS | Installation Instructions - Page 21
    VIKING RANGE CORPORATION Ventilateurs series de createur encastres de conception INSTALLATION droit.) 6. Tassez l'excedant de cable de cote et fixez-le afin d'eviter qu'il ne soit abirne par les objets ranges dans ('armoire. BORD DU COMPTOIR 1 TROU DE 7 mm (1/4 po) DIA. TROU DE 7 mm (1/4 po) DIA.
  • Viking DIPR150RSS | Installation Instructions - Page 22
    VIKING RANGE CORPORATION Ventilateurs series de createur encastres de conception Cette page a ete laissee en blanc volontairement. ARRIERE DU GABARIT DE LA TELECOMMANDE 22
  • Viking DIPR150RSS | Installation Instructions - Page 23
    VIKING RANGE CORPORATION Ventilateurs series de createur encastres de conception FONCTIONNEMENT HAUT/BAS - Re'eve ou abaisse leconduitd'aeration. Met le ventilateur en Tous les modeles MARCHElorsquele
  • Viking DIPR150RSS | Installation Instructions - Page 24
    depasser le prix des biens, services ou pieces faisant ('objet de la reclamation. GARANTIE DE REPARATION : Selon les conditions de cette garantie, les reparations doivent etre executees par une agence ou un representant agree de Viking Range Corporation. Les reparations s'effectueront pendant
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

VIKING
RANGE
CORPORATION
Designer
Series
Downdraft
Ventilators
MODEL
DIPR100R
DIPR16OR
DIPR15OR
WIDTH
30"
w/
remote
control
36"
w/
remote
control
45"
w/
remote
control
BLOWER
(purchase
separately)
VIDV500
Interior
or
VEDV900
Exterior
VIDV500
Interior
or
VEDV900
Exterior
VIDV500
Interior,
VEDV900
Exterior,
or
VEDV1200
Exterior
A
WARNING
-
To
reduce
the
risk
of
burns
or
ignition
of
clothing
by
reaching
across
burners,
the
downdraft
remote
control
MUST
be
mounted
in
the
countertop
-
at
least
4"
from
the
burners.
See
"INSTALL
COOKTOP"
section
on
page
8.
READ
AND
SAVE
THESE
INSTRUCTIONS
A
INTENDED
FOR
DOMESTIC
COOKING
ONLY
A
WARNING
A
al
WARNING
A
dti
TO
REDUCE
THE
RISK
OF
FIRE,
ELECTRIC
SHOCK,
OR
INJURY
TO
PERSONS,
OBSERVE
THE
FOLLOWING:
1.
Use
this
unit
only
in
the
manner
intended
by
the
manufacturer.
If
you
have
questions,
contact
the
manufacturer
at
the
address
or
telephone
number
in
the
warranty.
2.
Before
servicing
or
cleaning
unit,
switch
power
off
at
service
panel
and
lock
the
service
disconnecting
means
to
prevent
power
from
being
switched
on
accidentally.
When
the
service
disconnecting
means
cannot
be
locked,
securely
fasten
a
prominent
warning
device,
such
as
a
tag,
to
the
service
panel.
3.
Installation
work
and
electrical
wiring
must
be
done
by
a
qualified
person(s)
in
accordance
with
all
applicable
codes
and
standards,
including
fire
-rated
construction
codes
and
standards.
4.
Sufficient
air
is
needed
for
proper
combustion
and
exhausting
of
gases
through
the
flue
(chimney)
of
fuel
burning
equipment
to
prevent
backdrafting.
Follow
the
heating
equipment
manufacturer's
guideline
and
safety
standards
such
as
those
published
by
the
National
Fire
Protection
Association
(NFPA),
and
the
American
Society
for
Heating,
Refrigeration
and
Air
Conditioning
Engineers
(ASHRAE),
and
the
local
code
au-
thorities.
5.
When
cutting
or
drilling
into
wall
or
ceiling,
do
not
damage
electrical
wiring
and
other
hidden
utilities.
6.
Ducted
fans
must
always
be
vented
to
the
outdoors.
7.
To
reduce
the
risk
of
fire,
use
only
metal
ductwork.
8.
Do
not
install
this
product
with
the
activating
switch
directly
behind
a
burner
or
element.
Minimum
distance
between
the
switch
and
the
edge
of
the
burner
should
be
4
inches.
9.
Loose
-fitting
or
hanging
clothing
should
never
be
worn
when
operating
this
appliance.
They
may
be
ignited
by
burners/
elements
on
cooktop.
10.Children
should
not
be
left
alone
or
unattended
in
the
area
where
this
appliance
is
in
use.
11.
This
unit
must
be
grounded.
TO
REDUCE
THE
RISK
OF
A
RANGE
TOP
GREASE
FIRE:
a)
Never
leave
surface
units
unattended
at
high
settings.
Boilovers
cause
smoking
and
greasy
spillovers
that
may
ignite.
Heat
oils
slowly
on
low
or
medium
settings.
b)
Always
turn
hood
ON
when
cooking
at
high
heat
or
when
cooking
flaming
foods.
c)
Clean
ventilating
fans
frequently.
Grease
should
not
be
allowed
to
accumulate
on
fan
or
filter.
d)
Use
proper
pan
size.
Always
use
cookware
appropriate
for
the
size
of
the
surface
element.
TO
REDUCE
THE
RISK
OF
INJURY
TO
PERSONS
IN
THE
EVENT
OF
A
RANGE
TOP
GREASE
FIRE,
OBSERVE
THE
FOLLOWINGa:
1
SMOTHER
FLAMES
with
a
close
-fitting
lid,
cookie
sheet,
or
metal
tray,
then
turn
off
the
burner.
BE
CAREFUL
TO
PREVENT
BURNS.
If
the
flames
do
not
go
out
immedi
ately,
EVACUATE
AND
CALL
THE
FIRE
DEPARTMENT.
2.
NEVER
PICK
UP
A
FLAMING
PAN
-
You
may
be
burned.
3.
DO
NOT
USE
WATER,
including
wet
dishcloths
or
towels
-
a
violent
steam
explosion
will
result.
4.
Use
an
extinguisher
ONLY
if:
A.
You
know
you
have
a
Class
ABC
extinguisher,
and
you
already
know
how
to
operate
it.
B.
The
fire
is
small
and
contained
in
the
area
where
it
started.
C.
The
fire
department
is
being
called.
D.
You
can
fight
the
fire
with
your
back
to
an
exit.
a
Based
on
"Kitchen
Firesafety
Tips"
published
by
NFPA.
CAUTION
A
1.
For
general
ventilating
use
only.
Do
not
use
to
exhaust
hazardous
or
explosive
materials
and
vapors.
2.
To
avoid
motor
bearing
damage
and
noisy
and/or
unbalanced
impellers,
keep
drywall
spray,
construction
dust,
etc.
off
power
unit.
3.
Clean
filters
and
grease
-laden
surfaces
frequently.
4.
Do
not
repair
or
replace
any
part
of
this
appliance
unless
specifically
recommended
in
this
manual.
All
other
servicing
should
be
done
by
a
qualified
technician.
5.
Please
read
specification
label
on
product
for
further
informa-
tion
and
requirements.
INSTALLER:
Save
this
manual
for
Electrical
Inspector
and
Homeowner
to
use.
HOMEOWNER:
Use
and
Care
Information
on
Page
11.