be leak checked with a soap and water solution before
View all Weber Summit Platinum D6 LP manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 36 highlights
36 MAINTENANCE 13. Remove the Crossover® tube. 14. Pull the selected burner(s) tube(s) from manifold frame and replace with a new burner tube. 15. To reinstall the manifold assembly, reverse steps 7 through 14. ƽCAUTION: The burner openings (1) must be positioned properly over the valve orifices (2). Check proper assembly before fastening manifold in place. ƽWARNING: After reinstalling the gas lines, they should be leak checked with a soap and water solution before using the grill. (See, "Check for gas leaks.") (2) (1) CROSSOVER® IGNITION SYSTEM OPERATIONS If the Crossover® ignition system fails to ignite the LEFT burner in a burner set, light the LEFT burner with a match. If the LEFT burner lights with a match, then check the Crossover® ignition system. • Check that both ignition wires(1,2) are attached properly. (1 ) • Check that the Crossover® ignition button is activating. • You should hear the igniter sparking. If the Crossover® ignition system still fails to light, contact the Customer (2 ) Service Representative in your area using the contact information on our web site. Log onto www.weber.com®. REPLACE IGNITER BATTERIES Parts required: 1 AA alkaline battery per igniter. Unscrew igniter button from bottom of control panel. Remove igniter button and contact spring. Remove old battery and replace with a new AA alkaline battery. Positive end(1) of battery faces up as shown in illustration. Replace spring contact(2) and screw igniter button(3) back down.