ASRock 775i45GV User Manual - Page 29

Security Setup Menu

Page 29 highlights

Advanced AMIBIOS SETUP UTILITY - VERSION 3.31a System Hardware Monitor [ Setup Help ] CPU Temperature M/B Temperature CPU Fan Speed Chassis Fan Speed Vcore + 3.30V + 5.00V + 12.00V 35 C/ 95 F 32 27 C/ 82 F PCI 3110 RPM 0 RPM 1.375 V 3.312V 4.975V 12.167V F1:Help Esc:Previous Menu :Select Item +/-:Change Values Enter:Select Sub-Menu F9:Setup Defaults F10:Save & Exit 2. Security Setup Menu Main Advanced AMIBIOS SETUP UTILITY - VERSION 3.31a Security Power Boot Exit Supervisor Password User Password Set Supervisor Password Set User Password Clear Clear [ Enter ] [ Enter ] [ Setup Help ] to set the supervisor password. Password Check Setup F1:Help Esc:Exit :Select Item :Select Menu +/-:Change Values Enter:Select Sub-Menu F9:Setup Defaults F10:Save & Exit Supervisor Password: This field shows the status of the Supervisor Password. [Clear]: No password has been set. [Set]: Supervisor password has been set. User Password: This field shows the status of the User Password. [Clear]: No password has been set. [Set]: User password has been set. Set Supervisor Password: Press to set Supervisor Password. Valid password can be a 1 to 6 alphanumeric characters combination. If you already have a password, you must enter your current password first in order to create a new password. Set User Password: Press to set User Password. Valid password can be a 1 to 6 alphanumeric characters combination. If you already have a password, you must enter your current password first in order to create a new 29

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

29
2. Security Setup Menu
Supervisor Password:
This field shows the status of the Supervisor Password.
[Clear]:
No password has been set.
[Set]:
Supervisor password has been set.
User Password:
This field shows the status of the User Password.
[Clear]:
No password has been set.
[Set]:
User password has been set.
Set Supervisor Password:
Press <Enter> to set Supervisor Password. Valid
password can be a 1 to 6 alphanumeric characters combination. If you already
have a password, you must enter your current password first in order to
create a new password.
Set User Password:
Press <Enter> to set User Password. Valid password can
be a 1 to 6 alphanumeric characters combination. If you already have a
password, you must enter your current password first in order to create a new
AMIBIOS SETUP UTILITY - VERSION 3.31a
Main
Advanced
Security
Power
Boot
Exit
Supervisor Password
User Password
Set Supervisor Password
Set User Password
Password Check
[
Setup Help
]
Clear
Clear
<Enter> to set the
supervisor password.
F1:Help
Esc:Exit
F9:Setup Defaults
F10:Save & Exit
+/-:Change Values
Enter:Select
Sub-Menu
:Select Item
:Select Menu
[ Enter ]
Setup
[ Enter ]
AMIBIOS SETUP UTILITY - VERSION 3.31a
Advanced
CPU Temperature
M/B Temperature
CPU Fan Speed
Chassis Fan Speed
Vcore
+ 3.30V
+ 5.00V
+ 12.00V
[
Setup Help
]
F1:Help
Esc:Previous Menu
F9:Setup Defaults
F10:Save & Exit
+/-:Change Values
Enter:Select
Sub-Menu
:Select Item
System Hardware Monitor
32
PCI
35 C/ 95 F
27 C/ 82 F
3110 RPM
0 RPM
1.375 V
3.312V
4.975V
12.167V