ASRock Z790 Steel Legend WiFi Software/BIOS Setup Guide - Page 58

VF Offset Mode, Ring Voltage Offset, Extra Turbo Voltage, System Agent Voltage Mode

Page 58 highlights

VF Offset Mode Selects between Legacy and Selection modes. Need Reset System after enabling OverClocking Feature to Initialize the default value. In Legacy Mode, setting a global offset for the entire VF curve. In Selection modes, setting a selected VF point. Configuration options: [Legacy] [Selection] Ring Voltage Offset Specifies the Offset Voltage applied to the Ring domain. This voltage is specified in millivolts. GT Voltage Mode Selects between adaptive and Override Voltage modes. In Override Mode the voltage selected will be applied overall operating frequencies. In Adaptive Mode the voltage is interpolated only in turbo mode. This item appears when you use the onboard graphics. Configuration options: [Adaptive] [Override] Extra Turbo Voltage Specifies the extra turbo voltage applied while the GT is operating in turbo mode. Unit is in millivolts. GT Voltage Offset Specifies the Offset Voltage applied to the GT domain. This voltage is specified in millivolts. This item appears when you use the onboard graphics. System Agent Voltage Mode Selects between Adaptive and Override Voltage modes. In Override Mode the voltage selected will be applied overall operating frequencies. In Adaptive Mode the voltage is interpolated only in turbo mode. Configuration options: [Adaptive] [Override] Extra Turbo Voltage Specifies the extra turbo voltage applied while the SA Uncore is operating in turbo mode. Unit is in millivolts. System Agent Voltage Offset Specifies the Offset Voltage applied to the Uncore domain. This voltage is specified in millivolts. 54

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97

54
VF Offset Mode
Selects between Legacy and Selection modes. Need Reset System aſter enabling Over-
Clocking Feature to Initialize the default value. In Legacy Mode, setting a global offset for
the entire VF curve. In Selection modes, setting a selected VF point.
Configuration options: [Legacy] [Selection]
Ring Voltage Offset
Specifies the Offset Voltage applied to the Ring domain. °is voltage is specified in mil-
livolts.
GT Voltage Mode
Selects between adaptive and Override Voltage modes. In Override Mode the voltage
selected will be applied overall operating frequencies. In Adaptive Mode the voltage is
interpolated only in turbo mode. °is item appears when you use the onboard graphics.
Configuration options: [Adaptive] [Override]
Extra Turbo Voltage
Specifies the extra turbo voltage applied while the GT is operating in turbo mode. Unit is
in millivolts.
GT Voltage Offset
Specifies the Offset Voltage applied to the GT domain. °is voltage is specified in mil-
livolts. °is item appears when you use the onboard graphics.
System Agent Voltage Mode
Selects between Adaptive and Override Voltage modes. In Override Mode the voltage
selected will be applied overall operating frequencies. In Adaptive Mode the voltage is
interpolated only in turbo mode.
Configuration options: [Adaptive] [Override]
Extra Turbo Voltage
Specifies the extra turbo voltage applied while the SA Uncore is operating in turbo mode.
Unit is in millivolts.
System Agent Voltage Offset
Specifies the Offset Voltage applied to the Uncore domain. °is voltage is specified in mil-
livolts.