Acer AOD260 MSDS, UN38.3, CNAS of Battery pack for transportation - Page 7

Test Requirements - a

Page 7 highlights

UN Test Data (Model:3LUNA-1-T0636) 1.Test Item: Vibration (T3) P.5/10 2.Test Purpose: This test simulates vibration during transport. 3.Test Procedure: Cells and batteries are firmly secured to the platform of the vibration machine without distorting the cells in such a manner as to faithfully transmit the vibration. The vibration shall be a sinusoidal waveform with a logarithmic sweep between 7 Hz and 200 Hz and back to 7 Hz traversed in 15 minutes.This cycle shall be repeated 12 times for a total of 3 hours for each of three mutually perpendicular mounting positions of the cell. One of the directions of vibration must be perpendicular to the terminal face. The logarithmic frequency sweep is as follows: from 7 Hz a peak acceleration of 1gn is maintained until 18 Hz is reached. The amplitude is then maintained at 0.8 mm(1.6 mm total excursion) and thefrequency increased until a peak acceleration of 8gn occurs (approximately 50Hz).A peak acceleration of 8 gn is then maintained until the frequency is increased to 200Hz. SANYO Internal Procedure: As above. 4.Test Requirements: No mass loss(less than 0.1%),no leakage,no venting,no disassembly,no rupture and no fire,and the voltage retention is not less than 90%. The requirement relating to voltage is not applicable to test batteries at fully discharged states. 5.Test Date: 2010/2/2 6.Test Data Battery No. Mass(g) Mass loss Voltage(V) Voltage (%) Retention( Before test After test (=90%) Other event Result Judgement At first 1 161.95 cycle,in 2 161.92 fully charged 3 161.77 states 4 162.25 161.96 161.95 161.78 162.25 0.006 0.019 0.006 0.000 12.62 12.61 12.60 12.62 12.62 12.60 12.60 12.62 100.0 99.9 100.0 100.0 0 PASS 0 PASS 0 PASS 0 PASS At first 5 cycle,in 6 fully discharged 7 states 8 161.95 161.96 161.94 161.89 161.95 161.97 161.98 161.91 0.000 0.006 0.025 0.012 After 50 9 cycles ending in 10 fully 11 charged states 12 161.96 161.76 161.95 161.83 161.97 161.76 161.95 161.86 0.006 0.000 0.000 0.019 12.64 12.66 12.65 12.63 12.64 12.65 12.65 12.63 After 50 13 161.96 cycles ending in 14 162.03 161.98 162.04 0.012 0.006 fully 15 161.69 discharged states 16 161.91 161.71 161.92 0.012 0.006 Notes: L-Leakage, V-Venting, D-Disassembly, R-Rupture, F-Fire, 0-No leakage, no venting, no disassembly, no rupture & no fire 100.0 99.9 100.0 100.0 0 PASS 0 PASS 0 PASS 0 PASS PASS 0 PASS 0 PASS 0 PASS 0 PASS 0 PASS 0 PASS 0 PASS 0 PASS

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

UN Test Data
(Model:3LUNA-1-T0636)
1.Test Item:
Vibration (T3)
P.5/10
2.Test Purpose:
This test simulates vibration during transport.
3.Test Procedure:
Cells and batteries are firmly secured to the platform of the vibration machine without distorting the cells in such a
manner as to faithfully transmit the vibration. The vibration shall be a sinusoidal waveform with a logarithmic sweep
between 7 Hz and 200 Hz and back to 7 Hz traversed
in 15 minutes.This cycle shall be repeated 12 times for a
total of 3 hours for each of
three mutually perpendicular mounting positions of the cell. One of the directions of
vibration must be perpendicular to the terminal face.
The logarithmic frequency sweep is as follows: from 7 Hz a peak acceleration of 1gn is maintained until 18 Hz is
reached. The amplitude is then maintained at 0.8 mm(1.6 mm total excursion) and thefrequency increased until a
peak acceleration of 8gn occurs (approximately 50Hz).A peak acceleration of 8 gn is then maintained until the
frequency is increased to 200Hz.
SANYO Internal Procedure:
As above.
4.Test Requirements:
No mass loss(less than 0.1%),no leakage,no venting,no disassembly,no rupture and no fire,and the voltage
retention is not
less than 90%.
The requirement relating to voltage is not applicable to test batteries at fully discharged states.
5.Test Date:
2010/2/2
6.Test Data
Before test
After test
Before test
After test
1
161.95
161.96
0.006
12.62
12.62
100.0
0
PASS
2
161.92
161.95
0.019
12.61
12.60
99.9
0
PASS
3
161.77
161.78
0.006
12.60
12.60
100.0
0
PASS
4
162.25
162.25
0.000
12.62
12.62
100.0
0
PASS
5
161.95
161.95
0.000
0
PASS
6
161.96
161.97
0.006
0
PASS
7
161.94
161.98
0.025
0
PASS
8
161.89
161.91
0.012
0
PASS
9
161.96
161.97
0.006
12.64
12.64
100.0
0
PASS
10
161.76
161.76
0.000
12.66
12.65
99.9
0
PASS
11
161.95
161.95
0.000
12.65
12.65
100.0
0
PASS
12
161.83
161.86
0.019
12.63
12.63
100.0
0
PASS
13
161.96
161.98
0.012
0
PASS
14
162.03
162.04
0.006
0
PASS
15
161.69
161.71
0.012
0
PASS
16
161.91
161.92
0.006
0
PASS
Notes: L-Leakage, V-Venting, D-Disassembly, R-Rupture, F-Fire,
0-No leakage, no venting, no disassembly, no rupture & no fire
Other
event
Result
Judgement
At first
cycle,in
fully
charged
states
PASS
At first
cycle,in
fully
discharged
states
After 50
cycles
ending in
fully
charged
states
After 50
cycles
ending in
fully
discharged
states
Battery No.
Mass(g)
Mass loss
(%)
(=<0.1%)
Voltage(V)
Voltage
Retention(
%)(=>90%)