Acer TravelMate P245-MP Shipping Document - Page 5

UN Test Data, Model:3UR18650-2-T0590 - battery

Page 5 highlights

UN Test Data (Model:3UR18650-2-T0590) 1.Test Item: Altitude simulation (T1) 2.Test Purpose: This test simulates air transport under low-pressure conditions. 3.Test Procedure: Test cells and batteries shall be stored at a pressure of 11.6kPa or less for at least six hours at ambient temperature(20±5 ). SANYO Internal Procedure: As above. P.3/10 4.Test Requirements: No mass loss(less than 0.1%),no leakage,no venting,no disassembly,no rupture and no fire,and the voltage retention is not less than 90%. The requirement relating to voltage is not applicable to test batteries at fully discharged states. 5.Test Date: 2007/10/11 6.Test Data Battery No. Mass(g) Mass Voltage(V) Voltage loss (%) Retention( Before test After test (=90%) Other event Result Judgement At first 1 294.50 294.50 0.000 12.55 12.52 99.8 PASS cycle,in 2 293.74 293.71 0.010 12.54 12.52 99.8 fully charged 3 294.34 294.30 0.014 12.55 12.52 99.8 PASS PASS states 4 294.02 294.02 0.000 12.55 12.52 99.8 PASS At first 5 294.69 294.67 0.007 cycle,in 6 fully discharged 7 294.80 294.79 294.79 294.76 0.003 0.010 states 8 294.49 294.50 0.003 After 50 9 294.13 cycles ending in 10 294.68 294.13 294.68 0.000 0.000 12.56 12.56 fully 11 294.68 charged states 12 294.05 After 50 13 294.55 cycles ending in 14 294.59 294.67 294.05 294.55 294.60 0.003 0.000 0.000 0.003 12.56 12.56 fully 15 294.12 discharged states 16 294.41 294.12 294.38 0.000 0.010 Notes: L-Leakage, V-Venting, D-Disassembly, R-Rupture, F-Fire, 0-No leakage, no venting, no disassembly, no rupture & no fire 12.55 12.55 12.56 12.56 99.9 99.9 100.0 100.0 PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

UN Test Data
(Model:3UR18650-2-T0590)
1.Test Item:
Altitude simulation (T1)
P.3/10
2.Test Purpose:
This test simulates air transport under low-pressure conditions.
3.Test Procedure:
Test cells and batteries shall be stored at a pressure of 11.6kPa or less
for at least
six hours at ambient
temperature(20±5
).
SANYO Internal Procedure:
As above.
4.Test Requirements:
No mass loss(less than 0.1%),no leakage,no venting,no disassembly,no rupture and no fire,and the voltage
retention is not
less than 90%.
The requirement relating to voltage is not applicable to test batteries at fully discharged states.
5.Test Date:
2007/10/11
6.Test Data
Before test
After test
Before test
After test
1
294.50
294.50
0.000
12.55
12.52
99.8
0
PASS
2
293.74
293.71
0.010
12.54
12.52
99.8
0
PASS
3
294.34
294.30
0.014
12.55
12.52
99.8
0
PASS
4
294.02
294.02
0.000
12.55
12.52
99.8
0
PASS
5
294.69
294.67
0.007
0
PASS
6
294.80
294.79
0.003
0
PASS
7
294.79
294.76
0.010
0
PASS
8
294.49
294.50
0.003
0
PASS
9
294.13
294.13
0.000
12.56
12.55
99.9
0
PASS
10
294.68
294.68
0.000
12.56
12.55
99.9
0
PASS
11
294.68
294.67
0.003
12.56
12.56
100.0
0
PASS
12
294.05
294.05
0.000
12.56
12.56
100.0
0
PASS
13
294.55
294.55
0.000
0
PASS
14
294.59
294.60
0.003
0
PASS
15
294.12
294.12
0.000
0
PASS
16
294.41
294.38
0.010
0
PASS
Notes: L-Leakage, V-Venting, D-Disassembly, R-Rupture, F-Fire,
0-No leakage, no venting, no disassembly, no rupture & no fire
Voltage(V)
Voltage
Retention(
%)(=>90%)
Other
event
Result
Judgement
At first
cycle,in
fully
charged
states
PASS
At first
cycle,in
fully
discharged
states
After 50
cycles
ending in
fully
charged
states
After 50
cycles
ending in
fully
discharged
states
Battery No.
Mass(g)
Mass
loss (%)
(=<0.1%)