Chapter 3 Troubleshooting 3-1 LED Lighting Message Message Red Power LED Blue Input Power Plug Flash ON to OFF 100ms -- Standby V -- Power button ON -- V Lamp retry -- 0.5 second H(On), 0.5 second L(Off) flashing Power off (Cooling state) Power button OFF: Cooling completed; Standby Mode Error (Thermal Failure) 0.5 second H(ON), 0.5 second L(OFF) flashing -- V -- 0.5 second H(On), 0.5 second L(Off) flashing red twice, and blue LED ON 2 second, and by returns Error (Fan lock) 0.5 second H(On), 0.5 second L(Off) flashing red twice, and blue LED ON 2 second, and by returns Error (Lamp breakdown) 0.5 second H(On), 0.5 second L(Off) flashing blue twice, and red LED ON 2 second, and by returns Error (Color Wheel Failure) 0.5 second H(On), 0.5 second L(Off) flashing blue twice, and red LED ON 2 second, and by returns Note: Steady Light: "V" No Light: "--" X1161/X1261/X1161A/X1161N/X110/H5360 Confidential 3-