20" (50.8 cm) Freestanding Gas Range PRODUCT MODEL NUMBERS AGP200VD Gas supply: Provide a gas supply line of ³⁄₄" (1.9 cm) rigid pipe to the range location. A smaller size pipe on longer runs may result in insufficient gas supply. Pipe joint compounds that resist the action of LP gas must be used. Do not use TEFLON®† tape. With LP gas, piping or tubing size can be ¹⁄₂" (1.3 cm) minimum. Usually, LP gas suppliers determine the size and materials used in the system. If local codes permit, a new CSA design-certified, 4-5 ft (122-152.4 cm) long 1.3 cm) or ³⁄₄" (1.9 cm) I.D., flexible metal appliance connector may be used for connecting range to the gas supply line. A ¹⁄₂" (1.3 cm) male pipe thread is needed for connection to the female pipe threads of the inlet to the appliance gas pressure regulator. Must include a shutoff valve: The supply line must be equipped with a manual shutoff valve. This valve should be located in the same room but external to the range. It should be in a location that allows ease of opening and closing. Electrical: A 120-volt, 60-Hz, AC-only, 15-amp, fused electrical circuit is required. A time-delay fuse or circuit breaker is also recommended. It is recommended that a separate circuit serving only this range be provided. Do not use an extension cord. †®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company. PRODUCT DIMENSIONS 36" (91.5 cm) 19¹⁄₂" (49.5 cm) CABINET OPENING DIMENSIONS 42" (106.7 cm) 24¹⁄₂" (62.2 cm) 18" (45.7 cm) min. clearance upper side cabinet to countertop 13" (33.0 cm) max. upper cabinet depth 20" (50.8 cm) min. cabinet opening width 20¹⁄₈" (51.12 cm) opening width For minimum clearance to top of cooktop, see NOTE 3" (7.6 cm) min. countertop space to side wall or other combustible material This shaded area recommended for installation of gas pipe 10" (25.4 cm) 2¹⁄₂" (6.4 cm) 5¹⁄₂" 4" (14 cm) (10 cm) 2" (5.1 cm) Cabinet opening dimensions shown are for 25" (64 cm) countertop depth, 24" (61 cm) base cabinet depth and 36" (91.4 cm) countertop height. If the cabinet depth is greater than 24" (61 cm), the oven frame must extend beyond cabinet fronts by ¹⁄₂" (13 mm) minimum. NOTE: 24" (61 cm) minimum when bottom of wood or metal cabinet is covered by not less than ¹⁄₄" (0.64 cm) flame retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper. 30" (76.2 cm) minimum clearance between the top of the cooking platform and the bottom of an uncovered wood or metal cabinet. IMPORTANT: If installing a range hood or microwave hood combination above the range, follow the range hood or microwave hood combination installation instructions for dimensional clearances above the cooktop surface. Because Whirlpool Corporation policy includes a continuous commitment to improve Dimensions are for planning purposes only. For complete details, see Installation our products, we reserve the right to change materials and specifications without notice. Instructions packed with product. Specifications subject to change without notice. Ref. W10173324B 10/8/10

  • 1

20" (50.8 cm) Freestanding Gas Range
PRODUCT MODEL NUMBERS
PRODUCT DIMENSIONS
CABINET OPENING DIMENSIONS
AGP200VD
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Gas supply:
Provide a gas supply line of
³⁄₄
" (1.9 cm) rigid
pipe to the range location. A smaller size pipe on longer runs
may result in insufficient gas supply. Pipe joint compounds
that resist the action of LP gas must be used. Do not use
TEFLON
®†
tape. With LP gas, piping or tubing size can be
¹⁄₂
"
(1.3 cm) minimum. Usually, LP gas suppliers determine the
size and materials used in the system.
If local codes permit, a new CSA design-certified, 4-5 ft
(122-152.4 cm) long,
¹⁄₂
" (1.3 cm) or
³⁄₄
" (1.9 cm) I.D., flexible
metal appliance connector may be used for connecting range
to the gas supply line.
A
¹⁄₂
" (1.3 cm) male pipe thread is needed for connection to the
female pipe threads of the inlet to the appliance gas pressure
regulator.
Must include a shutoff valve:
The supply line must be equipped with a manual shutoff valve.
This valve should be located in the same room but external to
the range. It should be in a location that allows ease of opening
and closing.
Electrical:
A 120-volt, 60-Hz, AC-only, 15-amp, fused
electrical circuit is required. A time-delay fuse or circuit breaker
is also recommended. It is recommended that a separate
circuit serving only this range be provided.
Do not use an extension cord.
†®
TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
Ref. W10173324B
10/8/10
19
¹⁄₂
"
(49.5 cm)
24
¹⁄₂
"
(62.2 cm)
42"
(106.7 cm)
36"
(91.5 cm)
For minimum
clearance to
top of cooktop,
see
NOTE
This shaded area
recommended for
installation
of gas pipe
18" (45.7 cm)
min. clearance
upper side
cabinet to
countertop
13" (33.0 cm) max.
upper cabinet depth
20
¹⁄₈
" (51.12 cm)
opening width
20" (50.8 cm) min.
cabinet opening width
5
¹⁄₂
"
(14 cm)
2"
(5.1 cm)
2
¹⁄₂
"
(6.4 cm)
4"
(10 cm)
10" (25.4 cm)
3" (7.6 cm) min.
countertop space to
side wall or other
combustible material
Cabinet opening dimensions shown are for 25" (64 cm) countertop
depth, 24" (61 cm) base cabinet depth and 36" (91.4 cm) countertop
height.
If the cabinet depth is greater than 24" (61 cm), the oven frame must
extend beyond cabinet fronts by
¹⁄₂
" (13 mm) minimum.
NOTE:
24" (61 cm) minimum when bottom of wood or metal cabinet is
covered by not less than
¹⁄₄
" (0.64 cm) flame retardant millboard
covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm)
stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.
30" (76.2 cm) minimum clearance between the top of the cooking
platform and the bottom of an uncovered wood or metal cabinet.
IMPORTANT:
If installing a range hood or microwave hood
combination above the range, follow the range hood or microwave hood
combination installation instructions for dimensional clearances above
the cooktop surface.