Amana AGR3311WDW Dimension Guide - Page 1
Amana AGR3311WDW Manual
UPC - 883049185231
View all Amana AGR3311WDW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 1 highlights
® Freestanding Gas Range PRODUCT MODEL NUMBERS AGR3311WD OVERALL DIMENSIONS Gas supply: Use 3/4" (1.9 cm) rigid pipe gas supply line to the range location. A smaller size pipe on longer runs may result in insufficient gas supply. With L.P. gas, piping or tubing size can be 1/2" (1.3 cm) minimum. If local codes permit, it is recommended that new flexible metal tubing, design-certified by CSA, 4-5 feet (122-152.4 cm) long, 1/2" (1.3 cm) or 3/4" (1.9 cm) I.D., be used for connecting the range to the rigid gas supply line. A 1/2" (1.3 cm) male pipe thread is needed for connection to pressure regulator female pipe threads. An individual manual shutoff valve must be located in the same room, but external to the range. Electrical: 120-volt, 60-Hz, AC only, electrical supply is required on a separate 15-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. 26-3/4" (67.9 cm) depth with handle 24-1/4" (61.6 cm) 36" (91.4 cm) cooktop height 42" (106.7 cm) overall height 29-7/8" (75.9 cm) width CABINET OPENING DIMENSIONS Cabinet opening dimensions shown are for 25" (64 cm) countertop depth, 24" (61 cm) base cabinet depth and 36" (91.4 cm) countertop height. NOTE: 24" (61 cm) minimum when bottom of wood or metal cabinet is protected by not less than 1/4" (0.64 cm) flame retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper. 30" (76.2 cm) minimum clearance between the top of the cooking platform and the bottom of an unprotected wood or metal cabinet. If installing a range hood or microwave hood combination above the range, follow the range hood or microwave hood combination installation instructions for dimensional clearances above the cooktop surface. 18" (45.7 cm) min. clearance upper side cabinet to countertop This shaded area recommended for electrical outlet. 3" (7.6 cm) 13" (33.0 cm) max. upper cabinet depth 30" (76.2 cm) min. cabinet opening width 30-¹ ₈" (76.5 cm) opening width 2" (5.1 cm) min. countertop space to side wall or other combustible material For minimum clearance to top of cooktop, see NOTE. This shaded area recommended for installation of gas pipe. 24" (61.0 cm) 10" (25.4 cm) 5" (12.7 cm) 8" 5" (20.3 cm) (12.7 cm) 2" (5.1 cm) Because Whirlpool Corporation policy includes a continuous commitment to improve Dimensions are for planning purposes only. For complete details, see Installation our products, we reserve the right to change materials and specifications without notice. Instructions packed with product. Specifications subject to change without notice. Ref. W10130752 7-01-09