Behringer 2600-VCO Quick Start Guide - Page 7

Power Connection, Installation, Conexión Eléctrica, Instalación

Page 7 highlights

12 2600-VCO Power Connection P1 21 Red Stripe P2 12 10 9 200 mm ± 10 15 16 HOT USED + 12V GROUND - 12V + 12V GROUND - 12V Connect end P1 to the module socket Connect end P2 to the power supply The 2600-VCO module comes with the required power cable for connecting to a standard Eurorack power supply system. Follow these steps to connect the module to your Eurorack case. 1. Turn the power supply or rack case power off and disconnect the power cable. 2. Insert the 16-pin connector on the power cable into the socket on the power supply or rack case. The connector has a tab that will align with the gap in the socket, so it cannot be inserted incorrectly. If the power supply does not have a keyed socket, be sure to orient pin 1 (-12 V) with the red stripe on the cable. 3. Insert the 10-pin connector into the socket on the back of the module. The connector has a tab that will align with the socket for correct orientation. 4. After both ends of the power cable have been securely attached, you may mount the module in a case and turn on the power supply. Installation The necessary screws are included with the module for mounting in a Eurorack case. Connect the power cable before mounting. Depending on the rack case, there may be a series of fixed holes spaced 2 HP apart along the length of the case, or a track that allows individual threaded plates to slide along the length of the case. The free-moving threaded plates allow precise positioning of the module, but each plate should be positioned in the approximate relation to the mounting holes in your module before attaching the screws. Hold the module against the Eurorack rails so that each of the mounting holes are aligned with a threaded rail or threaded plate. Attach the screws part way to start, which will allow small adjustments to the positioning while you get them all aligned. After the final position has been established, tighten the screws down. Conexión Eléctrica P1 21 Red Stripe Quick Start Guide 13 P2 12 10 9 200 mm ± 10 15 16 HOT USED + 12V GROUND - 12V + 12V GROUND - 12V Connect end P1 to the module socket Connect end P2 to the power supply El módulo viene con el cable de alimentación necesario para conectarse a un sistema de suministro de energía Eurorack estándar. Siga estos pasos para conectar la alimentación al módulo. Es más fácil realizar estas conexiones antes de que el módulo se haya montado en una caja de rack. 1. Apague la fuente de alimentación o la caja del bastidor y desconecte el cable de alimentación. 2. Inserte el conector de 16 clavijas del cable de alimentación en la toma de la fuente de alimentación o en la caja del bastidor. El conector tiene una pestaña que se alineará con el espacio en el zócalo, por lo que no se puede insertar incorrectamente. Si la fuente de alimentación no tiene un enchufe con llave, asegúrese de orientar el pin 1 (-12 V) con la raya roja en el cable. 3. Inserte el conector de 10 pines en el zócalo en la parte posterior del módulo. El conector tiene una pestaña que se alineará con el enchufe para una orientación correcta. 4. Una vez que ambos extremos del cable de alimentación se hayan conectado de forma segura, puede montar el módulo en una caja y encender la fuente de alimentación. Instalación Los tornillos necesarios se incluyen con el módulo para su montaje en una caja Eurorack. Conecte el cable de alimentación antes del montaje. Dependiendo de la caja del bastidor, puede haber una serie de orificios fijos separados 2 HP a lo largo de la caja, o una pista que permita que las placas roscadas individuales se deslicen a lo largo de la caja. Las placas roscadas de movimiento libre permiten un posicionamiento preciso del módulo, pero cada placa debe colocarse en una relación aproximada con los orificios de montaje en su módulo antes de colocar los tornillos. Sostenga el módulo contra los rieles Eurorack de modo que cada uno de los orificios de montaje esté alineado con un riel o placa roscada. Coloque los tornillos parcialmente para comenzar, lo que permitirá pequeños ajustes en la posición mientras los alinea todos. Una vez establecida la posición final, apriete los tornillos.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13

Power Connection
The 2600-VCO module comes with the required power cable for connecting to a
standard Eurorack power supply system. Follow these steps to connect the module
to your Eurorack case.
1.
Turn the power supply or rack case power off and disconnect the power cable.
2.
Insert the 16-pin connector on the power cable into the socket on the power
supply or rack case. The connector has a tab that will align with the gap in the
socket, so it cannot be inserted incorrectly. If the power supply does not have a
keyed socket, be sure to orient pin 1 (-12 V) with the red stripe on the cable.
3.
Insert the 10-pin connector into the socket on the back of the module. The
connector has a tab that will align with the socket for correct orientation.
4.
After both ends of the power cable have been securely attached, you may mount
the module in a case and turn on the power supply.
Installation
The necessary screws are included with the module for mounting in a Eurorack case.
Connect the power cable before mounting.
Depending on the rack case, there may be a series of fixed holes spaced 2 HP apart
along the length of the case, or a track that allows individual threaded plates to
slide along the length of the case. The free-moving threaded plates allow precise
positioning of the module, but each plate should be positioned in the approximate
relation to the mounting holes in your module before attaching the screws.
Hold the module against the Eurorack rails so that each of the mounting holes are
aligned with a threaded rail or threaded plate. Attach the screws part way to start,
which will allow small adjustments to the positioning while you get them all aligned.
After the final position has been established, tighten the screws down.
Conexión Eléctrica
El módulo viene con el cable de alimentación necesario para conectarse a un sistema
de suministro de energía Eurorack estándar. Siga estos pasos para conectar la
alimentación al módulo. Es más fácil realizar estas conexiones antes de que el módulo
se haya montado en una caja de rack.
1.
Apague la fuente de alimentación o la caja del bastidor y desconecte el cable
de alimentación.
2.
Inserte el conector de 16 clavijas del cable de alimentación en la toma de la fuente
de alimentación o en la caja del bastidor. El conector tiene una pestaña que se
alineará con el espacio en el zócalo, por lo que no se puede insertar incorrectamente.
Si la fuente de alimentación no tiene un enchufe con llave, asegúrese de orientar el
pin 1 (-12 V) con la raya roja en el cable.
3.
Inserte el conector de 10 pines en el zócalo en la parte posterior del módulo. El conector
tiene una pestaña que se alineará con el enchufe para una orientación correcta.
4.
Una vez que ambos extremos del cable de alimentación se hayan conectado de
forma segura, puede montar el módulo en una caja y encender la fuente
de alimentación.
Instalación
Los tornillos necesarios se incluyen con el módulo para su montaje en una caja
Eurorack. Conecte el cable de alimentación antes del montaje.
Dependiendo de la caja del bastidor, puede haber una serie de orificios fijos separados
2 HP a lo largo de la caja, o una pista que permita que las placas roscadas individuales
se deslicen a lo largo de la caja. Las placas roscadas de movimiento libre permiten un
posicionamiento preciso del módulo, pero cada placa debe colocarse en una relación
aproximada con los orificios de montaje en su módulo antes de colocar los tornillos.
Sostenga el módulo contra los rieles Eurorack de modo que cada uno de los
orificios de montaje esté alineado con un riel o placa roscada. Coloque los tornillos
parcialmente para comenzar, lo que permitirá pequeños ajustes en la posición
mientras los alinea todos. Una vez establecida la posición final, apriete los tornillos.
HOT USED
Red Stripe
200 mm ± 10
15
16
2
1
P2
P1
2
10
9
1
Connect end P1 to the module socket
Connect end P2 to the power supply
+ 12V
- 12V
GROUND
+ 12V
- 12V
GROUND
HOT USED
Red Stripe
200 mm ± 10
15
16
2
1
P2
P1
2
10
9
1
Connect end P1 to the module socket
Connect end P2 to the power supply
+ 12V
- 12V
GROUND
+ 12V
- 12V
GROUND
12
13
Quick Start Guide
2600-VCO