Behringer DEQ2496 Specification Sheet - Page 4

Dimensions H x D x W

Page 4 highlights

4 ULTRACURVE PRO DEQ2496 Technical Specifications SPL Meter Weighting Microphone calibration Dynamics Type Threshold Attack Release Ratio Limiter Type Hold Threshold Release Real-Time Analyzer Type Frequency range Detectors Noise generator dB (A), dB (C) or OFF -42 dBV/Pa to -6 dBV/Pa Expander or compressor with digital IGC (Interactive Gain Control) variable from 0 to -60 dB 0 to 200 msec 20 to 4,000 msec 1:1.1 to 1:100 Peak limiter (zero attack) 0 to 1,000 msec variable from 0 to -24 dB 20 to 4,000 msec Display Type Backlighting Contrast Memory Presets Power Supply Mains voltage Power consumption Fuse Mains connector Dimensions/Weight Dimensions (H x D x W) digital 61-band FFT analyzer 20 Hz to 20 kHz, 61 bands according to ISO frequencies peak and average pink noise, levels from 0 to -60 dB Weight Shipping weight 320 x 80 dot-matrix LC display LED, orange adjustable 64 memory locations with 16-character names, single modules can be recalled and saved 85 to 250 V~, 50/60 Hz 10 W typ. T 1 A H Standard IEC receptacle 44.5 x 482.6 x 215 mm (1.75 x 19 x 8.5") approx. 2.24 kg (4.9 lbs) approx. 3.09 kg (6.8 lbs) BEHRINGER is constantly striving to maintain the highest professional standards. As a result of these efforts, modifications may be made from time to time to existing products without prior notice. Specifications and appearance may differ from those listed or illustrated. TECHNICAL SPECIFICATIONS AND APPEARANCES ARE SUBJECT TO CHANGE WITHOUT NOTICE AND ACCURACY IS NOT GUARANTEED. BEHRINGER, KLARK TEKNIK, MIDAS, BUGERA, AND TURBOSOUND ARE PART OF THE MUSIC GROUP (MUSIC-GROUP.COM). ALL TRADEMARKS ARE THE PROPERTY OF THEIR RESPECTIVE OWNERS. MUSIC GROUP ACCEPTS NO LIABILITY FOR ANY LOSS WHICH MAY BE SUFFERED BY ANY PERSON WHO RELIES EITHER WHOLLY OR IN PART UPON ANY DESCRIPTION, PHOTOGRAPH OR STATEMENT CONTAINED HEREIN. COLORS AND SPECIFICATIONS MAY VARY FROM ACTUAL PRODUCT. MUSIC GROUP PRODUCTS ARE SOLD THROUGH AUTHORIZED FULLFILLERS AND RESELLERS ONLY. FULLFILLERS AND RESELLERS ARE NOT AGENTS OF MUSIC GROUP AND HAVE ABSOLUTELY NO AUTHORITY TO BIND MUSIC GROUP BY ANY EXPRESS OR IMPLIED UNDERTAKING OR REPRESENTATION. THIS MANUAL IS COPYRIGHTED. NO PART OF THIS MANUAL MAY BE REPRODUCED OR TRANSMITTED IN ANY FORM OR BY ANY MEANS, ELECTRONIC OR MECHANICAL, INCLUDING PHOTOCOPYING AND RECORDING OF ANY KIND, FOR ANY PURPOSE, WITHOUT THE EXPRESS WRITTEN PERMISSION OF MUSIC GROUP IP LTD. ALL RIGHTS RESERVED. © 2013 MUSIC Group IP Ltd. Trident Chambers, Wickhams Cay, P.O. Box 146, Road Town, Tortola, British Virgin Islands

  • 1
  • 2
  • 3
  • 4

4
ULTRACURVE PRO DEQ2496 Technical Specifications
BEHRINGER
is constantly striving to maintain the highest professional standards. As a result of these efforts, modifications may be made from time to time to existing products without prior notice. Specifications and appearance may differ from those listed
or illustrated.
TECHNICAL SPECIFICATIONS AND APPEARANCES ARE SUBJECT TO CHANGE WITHOUT NOTICE AND ACCURACY IS NOT GUARANTEED. BEHRINGER, KLARK TEKNIK, MIDAS, BUGERA, AND TURBOSOUND ARE PART OF THE MUSIC GROUP (MUSIC-GROUP.COM).
ALL TRADEMARKS ARE THE PROPERTY OF THEIR RESPECTIVE OWNERS. MUSIC GROUP ACCEPTS NO LIABILITY FOR ANY LOSS WHICH MAY BE SUFFERED BY ANY PERSON WHO RELIES EITHER WHOLLY OR IN PART UPON ANY DESCRIPTION, PHOTOGRAPH
OR STATEMENT CONTAINED HEREIN. COLORS AND SPECIFICATIONS MAY VARY FROM ACTUAL PRODUCT. MUSIC GROUP PRODUCTS ARE SOLD THROUGH AUTHORIZED FULLFILLERS AND RESELLERS ONLY. FULLFILLERS AND RESELLERS ARE NOT AGENTS
OF MUSIC GROUP AND HAVE ABSOLUTELY NO AUTHORITY TO BIND MUSIC GROUP BY ANY EXPRESS OR IMPLIED UNDERTAKING OR REPRESENTATION. THIS MANUAL IS COPYRIGHTED. NO PART OF THIS MANUAL MAY BE REPRODUCED OR TRANSMITTED
IN ANY FORM OR BY ANY MEANS, ELECTRONIC OR MECHANICAL, INCLUDING PHOTOCOPYING AND RECORDING OF ANY KIND, FOR ANY PURPOSE, WITHOUT THE EXPRESS WRITTEN PERMISSION OF MUSIC GROUP IP LTD. ALL RIGHTS RESERVED.
© 2013 MUSIC Group IP Ltd. Trident Chambers, Wickhams Cay, P.O. Box 146, Road Town, Tortola, British Virgin Islands
SPL Meter
Weighting
dB (A), dB (C) or OFF
Microphone calibration
-42 dBV/Pa to -6 dBV/Pa
Dynamics
Type
Expander or compressor with digital
IGC (Interactive Gain Control)
Threshold
variable from 0 to -60 dB
Attack
0 to 200 msec
Release
20 to 4,000 msec
Ratio
1:1.1 to 1:100
Limiter
Type
Peak limiter (zero attack)
Hold
0 to 1,000 msec
Threshold
variable from 0 to -24 dB
Release
20 to 4,000 msec
Real-Time Analyzer
Type
digital 61-band FFT analyzer
Frequency range
20 Hz to 20 kHz, 61 bands according to
ISO frequencies
Detectors
peak and average
Noise generator
pink noise, levels from 0 to -60 dB
Display
Type
320 x 80 dot-matrix LC display
Backlighting
LED, orange
Contrast
adjustable
Memory
Presets
64 memory locations with
16-character names, single modules
can be recalled and saved
Power Supply
Mains voltage
85 to 250 V~, 50/60 Hz
Power consumption
10 W typ.
Fuse
T 1 A H
Mains connector
Standard IEC receptacle
Dimensions/Weight
Dimensions (H x D x W)
44.5 x 482.6 x 215 mm
(1.75 x 19 x 8.5")
Weight
approx. 2.24 kg (4.9 lbs)
Shipping weight
approx. 3.09 kg (6.8 lbs)