Bosch B36IT71SNS Instructions for Use - Page 25

Ice is forming in

Page 25 highlights

Fault Ice maker is not producing any ice. The ice maker is not producing enough ice or the ice cubes are misshapen. Ice is forming in the supply hose to the ice maker. Water is flowing out of the appliance. è Close shutĆoff valve immediately. Possible cause The ice cube container is in the false position. The water pressure is too low. The freezer compartment temperature is too high. A wrong water valve has been installedt. The water pressure is too low. The freezer compartment temperature is too low. Change the water filter. The water pressure is too low. The freezer compartment temperature is too high. The water pipe in the appliance is defective. The water pressure is too low. A wrong water valve has been installed. Remedial action Reinsert the container and slide it backwards to the end position (see section Variable interior design"). Check water pressure. The water pressure must be between 25 and 120 p.s.i. (1.72ć8.25 bar). Check temperature of the freezer compartment. If required, lower the temperature. SelfĆtapping valves and 3/16 inch (4.76 mm) saddle valves reduce the water pressure and may eventually block the pipe. The manufacturer is not liable for damage to property due to an incorrect installation or water connection. Check water pressure. The water pressure must be between 25 and 120 p.s.i. (1.72ć8.25 bar). Check temperature of the freezer compartment. If required increase the temperature. Instructions for changing the water filter can be found in the enclosed installation instructions. Check water pressure. The water pressure must be between 25 and 120 p.s.i. (1.72ć8.25 bar). Check temperature of the freezer compartment. If required, lower the temperature. Call customer service immediately. The valve may leak if the water pressure is too low. The water pressure must be between 25 and 120 p.s.i. (1.72ć8.25 bar). SelfĆtapping valves and 3/16 inch (4.76 mm) saddle valves reduce the water pressure and may eventually block the pipe. The manufacturer is not liable for damage to property due to an incorrect installation or water connection. 25

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88

25
Fault
Remedial action
Possible
cause
Ice maker is not producing
any ice.
The ice cube container is
in
the
false
position.
Reinsert
the container and
slide it
backwards
to
the
end
position
(see section
²Variable interior design").
The water
pressure is
too low.
Check
water pressure. The
water pressure must
be
between 25
and
120
p.s.i. (1.72ć8.25 bar).
The freezer
compartment
temperature
is too high.
Check
temperature of
the
freezer
compartment.
If±required,
lower the
temperature.
A
wrong
water
valve has been
installedt.
SelfĆtapping
valves
and
3/16
inch
(4.76
mm) saddle
valves
reduce the
water pressure and
may eventually
block
the pipe.
The
manufacturer
is not liable for
damage
to
property due to an incorrect installation or water
connection.
The
ice maker is not producing
enough
ice
or the ice
cubes are
The water
pressure is
too low.
Check
water pressure. The
water pressure must
be
between 25
and
120
p.s.i. (1.72ć8.25 bar).
misshapen.
The
freezer
compartment temperature
is too low.
Check
temperature of
the
freezer
compartment.
If±required
increase the temperature.
Change the
water filter.
Instructions
for changing
the water filter can be
found in
the
enclosed
installation
instructions.
Ice is forming in the
supply hose to
the ice maker.
The water
pressure is
too low.
Check
water pressure. The
water pressure must
be
between 25
and
120
p.s.i. (1.72ć8.25 bar).
The freezer
compartment
temperature
is too high.
Check
temperature of
the
freezer
compartment.
If±required,
lower the
temperature.
Water is flowing out of the
appliance.
The
water
pipe in the appliance is
defective.
Call
customer service
immediately.
è
Close shutĆoff
valve immediately.
The
water
pressure is
too low.
The valve may
leak
if
the water pressure is
too
low.
The±water pressure must
be between
25
and 120 p.s.i.
(1.72ć8.25
bar).
A wrong
water
valve has
been
installed.
SelfĆtapping
valves
and
3/16
inch
(4.76
mm) saddle
valves
reduce the
water pressure and
may eventually
block
the pipe.
The
manufacturer
is not liable for
damage
to
property due to an incorrect installation or water
connection.