Bosch DVR6E1082 Installation Instructions

Bosch DVR6E1082 Manual

Bosch DVR6E1082 manual content summary:

  • Bosch DVR6E1082 | Installation Instructions - Page 1
    Divar - Digital Versatile Recorder EN Installation Instructions
  • Bosch DVR6E1082 | Installation Instructions - Page 2
  • Bosch DVR6E1082 | Installation Instructions - Page 3
    Divar | Installation Manual Bosch Security Systems EN | i Divar Digital Versatile Recorder Installation manual Chapters 1. 2. 3. 4. 5. 6 7 8. Introduction Quick install Operating instructions Hardware setup Menu system Using the Configuration Tool Menu default values Technical specifications
  • Bosch DVR6E1082 | Installation Instructions - Page 4
    Divar | Installation Manual EN | ii Introduction 1-1 Digital video recorder for security applications DVR name 2-6 IP address, Subnet mask and Default gateway 2-6 MAC address 2-6 Bandwidth limit 2-6 Operating instructions connections 4-2 Monitor connections 4-3 Bosch Security Systems
  • Bosch DVR6E1082 | Installation Instructions - Page 5
    Divar | Installation Manual EN | iii Console port connection 4-3 Keyboard connections 4-4 Ethernet connection 4-5 Control port 4-6 External main window 6-5 Overview button 6-5 History button 6-5 Settings button 6-5 Service button 6-6 Help button 6-6 Logout button 6-6 Using the control
  • Bosch DVR6E1082 | Installation Instructions - Page 6
    Divar | Installation Manual SAFETY PRECAUTIONS CAUTION RISK OF ELECTRIC SHOCK. DO NOT OPEN! CAUTION: TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT OPEN COVERS. NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE and maintenance (servicing) instructions in the Bosch Security Systems
  • Bosch DVR6E1082 | Installation Instructions - Page 7
    Divar | Installation Manual EN for long periods of time. 14. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged respect to proper grounding of the mount and supporting structure, grounding of the coax to a discharge Bosch Security Systems
  • Bosch DVR6E1082 | Installation Instructions - Page 8
    Divar | Installation Manual EN | vi FCC & ICES INFORMATION (U.S.A. and Canadian Models Only) This is a Class B product. This device complies with Part screen Play forward Pause Play reverse Freeze Fast forward Zoom Fast reverse Sequence Alarm Motion Network Error Bosch Security Systems
  • Bosch DVR6E1082 | Installation Instructions - Page 9
    Divar | Installation Manual | Introduction Bosch Security Systems CHAPTER 1 Introduction EN | 1-1 Digital video recorder for security applications The Divar is a video recording system that can record multiple camera signals while simultaneously providing live multiscreen viewing and playback. It
  • Bosch DVR6E1082 | Installation Instructions - Page 10
    Divar Bilinx supports the use of Bilinx cameras. Bilinx technology embeds control commands in the video signal enabling direct camera access and control through a single video coaxial cable. This manual is reduced. Instructions that only outputs. • Compatibility with Bosch D9000 series control panels
  • Bosch DVR6E1082 | Installation Instructions - Page 11
    Service Representative or Bosch Divar 16, Divar 9 or Divar 6 unit) • Quick reference guide • Divar operation manual • Divar Control Center and Archive Player operation manual • Installation manual (this manual Divar loop-through cable • Rack mounting kit • A CD-ROM with the software and the manuals
  • Bosch DVR6E1082 | Installation Instructions - Page 12
    Divar | Installation Manual . • Pan/tilt/zoom control units. • Bosch D9000 series control panels. • SCSI cable for Divar automatically detects new Archive Player software. Follow the instructions that appear on your monitor screen to load the latest Archive Player software. • The DVD writer supports
  • Bosch DVR6E1082 | Installation Instructions - Page 13
    Divar | Installation Manual | Quick install CHAPTER 2 Quick install EN | 2-1 This chapter gives instructions on how to quickly get the unit operational. Make the connections described on the unit. When you have entered the relevant information the unit will be operational. Bosch Security Systems
  • Bosch DVR6E1082 | Installation Instructions - Page 14
    Divar | Installation Manual | Quick install Quick connection EN | 2-2 ATM/POS bridge PC LAN / WAN 8 RS232 Terminator** 9 DIVAR / 390 Ohm 6 1 x16* VIDEO IN VIDEO IN AutoDome Storage Array 7 AutoDome SHIELD 11 2 A 110 - 240 Vac *can be 6, 9 or 16 depending on model Bosch Security Systems
  • Bosch DVR6E1082 | Installation Instructions - Page 15
    Divar | Installation Manual | Quick install EN | 2-3 Primary connections 1. Connect the cameras to the BNC loop-through camera inputs (automatically terminated). 2. Connect monitor key to select a submenu or item. • Use the escape key to go back or to switch off the menu. Bosch Security Systems
  • Bosch DVR6E1082 | Installation Instructions - Page 16
    Divar | Installation Manual | Quick install EN | 2-4 QUICK INSTALL MENU > QUICK INSTALL LANGUAGE TIME ZONE TIME FORMAT TIME DATE FORMAT DATE ACTIVE CAMS ALARM into the unit and exit the Quick Install. >> CANCEL • Select this item to exit the Quick Install without saving. Bosch Security Systems
  • Bosch DVR6E1082 | Installation Instructions - Page 17
    Divar | Installation Manual | Quick install EN | 2-5 >> RECORDING SETTINGS RECORDING SETTINGS DAY PERIOD WEEKEND REC DAY REC WEEKEND/NIGHT ENABLE ALARM INPUTS FOR motion is detected. Select the recording speed to be used for each of the cameras when motion is detected. Bosch Security Systems
  • Bosch DVR6E1082 | Installation Instructions - Page 18
    Divar | Installation Manual | Quick install EN | 2-6 default gateway assigned automatically by the network server. The actual values are displayed. >> DVR NAME • Enter a Divar name to be used in the network. >> IP ADDRESS, SUBNET MASK AND 0 and 100 for the bandwidth limit. Bosch Security Systems
  • Bosch DVR6E1082 | Installation Instructions - Page 19
    Divar | Installation Manual | Operating instructions EN | 3-1 CHAPTER 3 Operating instructions The instructions in this chapter explain the purpose of the front panel keys. The functions available can be limited by setting passwords. Some functions may also require a software license. An
  • Bosch DVR6E1082 | Installation Instructions - Page 20
    Divar | Installation Manual | Operating instructions Front panel controls Divar Bilinx Divar Bilinx Divar Bilinx with internal DVD writer DVD writer Open/Close button Divar Bilinx DVD writer Read/Write LED Bosch Security Systems EN | 3-2
  • Bosch DVR6E1082 | Installation Instructions - Page 21
    Divar | Installation Manual | Operating instructions EN | 3-3 Indicators The power indicator unit. lights to indicate that power is being supplied to the The monitor B key or sequence key is pressed. When in a menu, the keys operate according to their alternate function. Bosch Security Systems
  • Bosch DVR6E1082 | Installation Instructions - Page 22
    Divar | Installation Manual | Operating instructions EN | 3-4 Primary functions (light below ALT key off) Live key - press to switch to live viewing. Search key - press or enter a password. - press current camera key to switch the display of the ATM/POS data on and off. Bosch Security Systems
  • Bosch DVR6E1082 | Installation Instructions - Page 23
    Divar | Installation Manual | Operating instructions Alternate functions (light below ALT key is lit) F1 key F2 key - restores defaults in active menu. - is assigned -screen or quad displays. Zoom key - zooms in on the active camera display (full-screen or active cameo). Bosch Security Systems
  • Bosch DVR6E1082 | Installation Instructions - Page 24
    Divar | Installation Manual | Operating instructions EN | 3-6 Viewing pictures The unit has two monitor outputs, A and B. The way in which 7 5+1 2 1 3 4 5 6 The quad mode can have 4 different quad screens that can be shown in sequence to display 16 camera pictures. Bosch Security Systems
  • Bosch DVR6E1082 | Installation Instructions - Page 25
    Divar | Installation Manual | Operating instructions EN | 3-7 Multiscreen To view different multiscreen displays on monitor A: 1. Press the multiscreen key . > A multiscreen display of used on a frozen picture. If you change viewing mode, any frozen pictures are released. Bosch Security Systems
  • Bosch DVR6E1082 | Installation Instructions - Page 26
    Divar | Installation Manual | Operating instructions Zoom To zoom in on a camera picture: 1. Press the ALT key . > The ALT indicator lights. 2. Press the zoom key . . 7. Press the ALT key to return the keys to normal operation. > The ALT indicator no longer lights. Bosch Security Systems EN | 3-8
  • Bosch DVR6E1082 | Installation Instructions - Page 27
    Divar | Installation Manual | Operating instructions EN | 3-9 Live, playback and search modes Live mode The live mode is the normal operating mode of the unit where back to live viewing or press the search key to switch to the search mode. In both cases, playback stops. Bosch Security Systems
  • Bosch DVR6E1082 | Installation Instructions - Page 28
    Divar | Installation Manual | Operating instructions EN | 3-10 Protecting or video segment to a (re)writable disk. Select Protect & Archive to do both. The software required to play a video segment on a PC (the Archive Player) is copied to the time to start time. Bosch Security Systems
  • Bosch DVR6E1082 | Installation Instructions - Page 29
    Divar | Installation Manual | Operating instructions • Fill in a time and date from which to start the search. • Fill in an end time and date to limit the escape key to return to the filter menu. PLAYBACK SEARCH SEARCH RESULTS CAMERA 1 MOTION EN | 3-11 2002-03-14 15:00:17 Bosch Security Systems
  • Bosch DVR6E1082 | Installation Instructions - Page 30
    Divar | Installation Manual | Operating instructions EN | 3-12 Triggers and alarms Various types of events can change the way the unit works. These events can . A trigger may change the way the camera images are displayed on the monitors without requiring your intervention. Bosch Security Systems
  • Bosch DVR6E1082 | Installation Instructions - Page 31
    Divar | Installation Manual | Operating instructions EN | 3-13 Alarm inputs If an input causes an alarm • Monitors A and B can switch to a pre-programmed view mode the dwell time. Using motion detection outdoors may cause false alarms because of varying light conditions. Bosch Security Systems
  • Bosch DVR6E1082 | Installation Instructions - Page 32
    Divar | Installation Manual | Operating instructions EN | 3-14 Video loss alarm If the loss of a video signal causes an alarm: Monitor A or B can . 2. To avoid losing information, take corrective action to free disk space (for example, archive and delete some recordings). Bosch Security Systems
  • Bosch DVR6E1082 | Installation Instructions - Page 33
    Manual | Hardware setup EN | 4-1 CHAPTER 4 Hardware setup This chapter contains detailed information about the connection of external equipment to the unit. The connector types and their pin signals are described. All the connectors are located at the rear panel of the unit. Bosch Security
  • Bosch DVR6E1082 | Installation Instructions - Page 34
    The Divar automatically support the Bilinx communications standard can be directly connected to the BNC connectors if your Divar version is Bilinx-enabled. If Bilinx cameras are looped-through to multiple Divars, only one Divar Divar Bilinx only). PAL/NTSC, auto-detect. Automatic or manual
  • Bosch DVR6E1082 | Installation Instructions - Page 35
    Divar | Installation Manual is used to connect a PC to the unit for configuration or service purposes. Use a null-modem cable to connect the serial port of connector is also used to connect Bosch D9000 series control panels via an interface unit for Divar alarm activation. Alarm input mapping
  • Bosch DVR6E1082 | Installation Instructions - Page 36
    Divar | Installation Manual | Hardware setup Keyboard connections The keyboard input and output connectors are used to connect an 3 4 5 6 Signal No Connection System ground Keyboard minus line Keyboard plus line System ground No Connection 6 1 42 EN | 4-4 Panel view Bosch Security Systems
  • Bosch DVR6E1082 | Installation Instructions - Page 37
    Divar | Installation Manual | Hardware setup Ethernet connection The standard RJ-45 Ethernet socket is used to connect the unit directly to a PC or Receive line plus No Connection No Connection Ethernet receive line minus No Connection No Connection 81 EN | 4-5 Panel view Bosch Security Systems
  • Bosch DVR6E1082 | Installation Instructions - Page 38
    Divar | Installation Manual | Hardware setup EN | 4-6 Control port The control port is a bi-phase port for connecting the control units of ch. 4 (plus) System ground/cable shield. Bi-phase control ch. 5 (minus) Bi-phase control ch. 5 (plus) System ground/cable shield. Bosch Security Systems
  • Bosch DVR6E1082 | Installation Instructions - Page 39
    Divar | Installation Manual | Hardware setup EN | 4-7 External I/O connection Alarm inputs and outputs are supplied via a 25-pole D- Alarm_in_3 Alarm_in_4 Alarm_in_5 Pin no. 1 2 3 4 5 Description Alarm input 1 Alarm input 2 Alarm input 3 Alarm input 4 Alarm input 5 Bosch Security Systems
  • Bosch DVR6E1082 | Installation Instructions - Page 40
    Divar | Installation Manual | Hardware setup Signal name: Alarm_in_6 Alarm_in_7 output pole 1 Relay 3 output pole 2 Relay 4 output pole 1 Relay 4 output pole 2 Chassis Ground Bosch Security Systems EN | 4-8 SCSI connection The unit provides a 50-pin high density SCSI-2 port for connection
  • Bosch DVR6E1082 | Installation Instructions - Page 41
    Divar | Installation Manual | Hardware setup EN | 4-9 Power Supply Power is supplied to the unit is limited to external cleaning and inspection. Refer all servicing to qualified personnel. WARNING! Do not open the top cover or attempt to service the unit as this may expose you to dangerous voltages
  • Bosch DVR6E1082 | Installation Instructions - Page 42
    Divar | Installation Manual | Hardware setup EN | 4-10 Bosch Security Systems
  • Bosch DVR6E1082 | Installation Instructions - Page 43
    Divar | Installation Manual | Menu system CHAPTER 5 Menu system EN | 5-1 You access all the parameters used to set up the unit via the menu system. documents the full structure of the menu system. To find out how to use the PCbased Configuration Tool refer to Chapter 6. Bosch Security Systems
  • Bosch DVR6E1082 | Installation Instructions - Page 44
    Divar | Installation Manual | Menu system EN | 5-2 Overview of the menu system The main menu consists of six menu groups: History. The History menu allows key to select a submenu or item. • Use the escape key to go back. Access to some menu items can be password protected. Bosch Security Systems
  • Bosch DVR6E1082 | Installation Instructions - Page 45
    Divar | Installation Manual | Menu system MAIN MENU The main menu gives access to six major menu groups Main menu History Disk manager Time / Date View settings System settings Profiles Advanced menus Bosch Security Systems * advanced items EN | 5-3 History View history list Disk manager Status
  • Bosch DVR6E1082 | Installation Instructions - Page 46
    Divar | Installation Manual | Menu system EN | 5-4 HISTORY > The History menu provides a list of all events that have occurred. This list can be and alarm and motion frequency. The estimated recording time shown depends on the available storage capacity and recording setup. Bosch Security Systems
  • Bosch DVR6E1082 | Installation Instructions - Page 47
    Divar | Installation Manual | Menu system EN | 5-5 >> LOCAL ARCHIVING • Segments of recorded video can be written to (re)writable disks using the local (or press F1) to place a protected recoding in the archive list. • Recordings to be archived are indicated by an A. Bosch Security Systems
  • Bosch DVR6E1082 | Installation Instructions - Page 48
    Divar | Installation Manual | Menu system EN | 5-6 >> AUTHENTICITY CHECK • This check verifies that video images and associated data have not been modified. recordings are not deleted. >> ERASE DISK • Deletes all recorded video on the disk. • You must confirm the deletion. Bosch Security Systems
  • Bosch DVR6E1082 | Installation Instructions - Page 49
    Divar | Installation Manual | Menu system EN | 5-7 TIME/ connected units are automatically synchronized every hour from the time and date of the unit with DVR ID 1. VIEW SETTINGS > The View Settings menu allows you to set up the display access the Adjust Contrast submenu. Bosch Security Systems
  • Bosch DVR6E1082 | Installation Instructions - Page 50
    Divar | Installation Manual | Menu system EN | 5-8 Adjust contrast • Select a camera in the menu or press a camera key on the unit. The selected camera image appears. • Vary the manual gain value between -100 and +100 to five minutes if you set the Menu Time-out to On. Bosch Security Systems
  • Bosch DVR6E1082 | Installation Instructions - Page 51
    Divar | Installation Manual | Menu multiscreen modes that are available depend on the number of cameras connected and the Divar model. >>> ATM/POS (requires bridge and license) • ATM/POS data disk is full. Older recordings must be manually deleted. • Set the Pre-event time so that recording begins before
  • Bosch DVR6E1082 | Installation Instructions - Page 52
    Divar | Installation Manual to assign a name to each of the 16 Divar inputs. • If an alarm panel is connected to from the alarm panel with the 16 Divar inputs. • Select the Auto-protect submenu 16 alarm inputs, select either the physical Divar input (the physical input is automattically mapped
  • Bosch DVR6E1082 | Installation Instructions - Page 53
    Divar | Installation Manual | Menu system EN | 5-11 Auto-protect • Four inputs can be used to trigger automatic protection of video clips. • Select the inputs any video loss occurs. >> HISTORY LOG SETUP • Select Yes for those events that you want to log in the history file. Bosch Security Systems
  • Bosch DVR6E1082 | Installation Instructions - Page 54
    Divar | Installation Manual | assigned automatically by the network server. The actual values are displayed. • Enter a Divar name to be used in the network. • Fill in the IP, subnet the camera numbers for the different Divars. • Only default camera identification numbers (Camera 1, Camera 2, etc.) are
  • Bosch DVR6E1082 | Installation Instructions - Page 55
    Divar | Installation Manual | Menu system EN | 5-13 >>> COM port • The COM port is an RS232 serial port used mainly for connecting a PC or an alarm panel • To see the other days of the week use the left /right arrow keys. • Select the Add Schedule item to edit the calendar. Bosch Security Systems
  • Bosch DVR6E1082 | Installation Instructions - Page 56
    Divar | Installation Manual | Menu system EN | 5-14 Add schedule • Select the profile name, the begin and end times, and the days on which you selection. A check mark means enabled. • Enabled selections act as triggers. If alarm is checked, the selection acts as an alarm. Bosch Security Systems
  • Bosch DVR6E1082 | Installation Instructions - Page 57
    Divar | Installation Manual | Menu system EN | 5-15 >>> Output handling • Select the profile for which you wish to configure the output handling. • Select the , enter the number of the source profile, enter the number of the destination profile and select the Copy Now item. Bosch Security Systems
  • Bosch DVR6E1082 | Installation Instructions - Page 58
    Divar | Installation Manual | Menu system EN | 5-16 Bosch Security Systems
  • Bosch DVR6E1082 | Installation Instructions - Page 59
    Divar | Installation Manual | Using the Configuration Tool EN | 6-1 CHAPTER 6 Using the Configuration Tool The Configuration Tool is a software application that makes the installation and configuration of a unit faster and easier. The Configuration Tool runs on a PC that is connected to the Divar
  • Bosch DVR6E1082 | Installation Instructions - Page 60
    Divar | Installation Manual it. 3. Follow the instructions on the screen and select Serial connection entry from the DVR list. Network connection To program. Alternatively, select the Divar Configuration Tool program via the Divar version, model, the video standard and the cameras that are connected
  • Bosch DVR6E1082 | Installation Instructions - Page 61
    the Divar itself. 3. Type a name in the Name box or retrieve it from the Divar by checking the Retrieve from Divar box. 4. Click Add. To delete a Divar from the list: 1. In the list, select the Divar you wish to delete. 2. Click Delete. > The selected Divar is removed from the list. Bosch Security
  • Bosch DVR6E1082 | Installation Instructions - Page 62
    Divar | Installation Manual | Using the Configuration Tool EN | 6-4 Login When you start the Configuration tool application, the Login window appears. (Click Cancel to discontinue login and exit the application.) To control a particular Divar: 1. Select the Divars items. Bosch Security Systems
  • Bosch DVR6E1082 | Installation Instructions - Page 63
    Divar | Installation Manual | Using the Configuration Tool EN | 6-5 Introducing the main window The Configuration Tool window is divided into 3 panes. parameters for that menu item. • Select the values you want for the parameters. • These values are updated immediately. Bosch Security Systems
  • Bosch DVR6E1082 | Installation Instructions - Page 64
    Divar | Installation Manual | Using the Configuration Tool EN | 6-6 Service button Click the Service button to get a list of diagnostic messages and to access the firmware update function. button to open a list of the Divars in the network to which you can download selected settings. Select those
  • Bosch DVR6E1082 | Installation Instructions - Page 65
    Divar | Installation Manual | Using the Configuration Tool EN | 6-7 Refining settings When you select Import, Export or Download a pop-up window allows you to in a text file. Clear Click the clear button values. to set all settings on the active page to their default Bosch Security Systems
  • Bosch DVR6E1082 | Installation Instructions - Page 66
    Divar | Installation Manual | Using the Configuration Tool EN | 6-8 Bosch Security Systems
  • Bosch DVR6E1082 | Installation Instructions - Page 67
    Divar | Installation Manual | Menu default values EN | 7-1 CHAPTER 7 Menu default values The table on the following pages lists the items of the menu system of these menu items. These values are restored when the Factory defaults item of the System settings menu is selected. Bosch Security Systems
  • Bosch DVR6E1082 | Installation Instructions - Page 68
    Manual | Menu default values Level 1 History Time / Date Level 2 Show alarms Show motions Show network connectivity Show errors Time zone Level 3 Time format Date format Synchronize View Settings Daylight saving Camera setup Use timer server IP address Camera name Camera lock-out Bosch
  • Bosch DVR6E1082 | Installation Instructions - Page 69
    Divar | Installation Manual | Menu default values Level 1 Level 2 Level 3 Camera control Camera controllable Level 4 Auto camera contrast Adjust contrast Level 5 Position Duration Text intensity Font size Bosch Security Systems EN | 7-3 Default value On 0 No cameras selected All cameras
  • Bosch DVR6E1082 | Installation Instructions - Page 70
    Divar | Installation Manual | Menu default values Level 1 System Settings Level 2 Language Recording Setup Level 3 Record mode Overwrite protection Pre-event . None Disable No block 5 seconds 5 seconds Relay 1 Enable None/PP01 None/PP01 INPUT 01 ... INPUT 16 None 5 minutes Bosch Security Systems
  • Bosch DVR6E1082 | Installation Instructions - Page 71
    Divar | Installation Manual | Menu default values Level 1 Level 2 Level 3 Motion Setup Video loss Setup History log setup Connectivity Log alarms Log motions Log video loss Log errors Log network Keyboard access Network setup Bosch Security Systems Level 4 Output relay Beeper Display
  • Bosch DVR6E1082 | Installation Instructions - Page 72
    Divar | Installation Manual | Menu default values Level 1 Level 2 Level 3 Network access Expand system Com port Input and Output contacts Inputs Outputs Level 4 Default gateway HTTP port Bandwidth limit IP Range List of users DVR 1 1 CCL 9600 None 8 1 On N/O N/O Bosch Security Systems
  • Bosch DVR6E1082 | Installation Instructions - Page 73
    Divar | Installation Manual | Menu default values EN | 7-7 Level 1 Profiles Level 2 Profile manager System behavior Level 3 Level 4 Camera pre-position Enable List all cameras, quality, IPS Medium, 1IPS Cameras not in alarm, IPS Recording duration No change 30 seconds Bosch Security Systems
  • Bosch DVR6E1082 | Installation Instructions - Page 74
    Divar | Installation Manual | Menu default values Level 1 Level 2 Level 3 Access restrictions Advanced menus Copy system behavior EN | 7-8 Level 4 Motion Select profile Recording duration No change 15 seconds 1 Disable Access Access Access Access Access None None No Bosch Security Systems
  • Bosch DVR6E1082 | Installation Instructions - Page 75
    Divar | Installation Manual | Technical specifications EN | 8-1 CHAPTER 8 Technical specifications The following pages give the technical specifications of the unit. Bosch Security Systems
  • Bosch DVR6E1082 | Installation Instructions - Page 76
    Divar | Installation Manual | Technical specifications EN | 8-2 Electrical Voltage and Power All models 100-240 VAC; 0.7-0.3A ½, 1/5, 1/10, 0, Never PAL: 50 total, configurable per camera: 25, 12.5, 8, 6, 5, 4, 3, 2, 1, ½, 1/5, 1/10, 0, Never 720 x 288 PAL - 720 x 242 NTSC Bosch Security Systems
  • Bosch DVR6E1082 | Installation Instructions - Page 77
    Divar | Installation Manual | Technical specifications EN | 8-3 DVD writer Write speeds: Divar write speed: DVD+R / DVD+RW: 4x (or higher) CD-R: 40x (or higher) CD-RW: 24x code translaters Keyboard port expander ATM/POS bridge ATM/POS software license External CD/DVD writer Bosch Security Systems
  • Bosch DVR6E1082 | Installation Instructions - Page 78
    Divar | Installation Manual | Technical specifications EN | 8-4 Bosch Security Systems
  • Bosch DVR6E1082 | Installation Instructions - Page 79
  • Bosch DVR6E1082 | Installation Instructions - Page 80
    Bosch Sicherheitssysteme GmbH Ludwig-Bölkow-Allee 85521 Ottobrunn Germany www.bosch-sicherheitssysteme.de Bosch Security Systems B.V. P.O. Box 80002 5600 JB Eindhoven The Netherlands www.boschsecuritysystems.com © 2005 Bosch Security Systems B.V. Subject to change. Printed in Portugal.
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80

Divar - Digital Versatile Recorder
Installation Instructions
EN