Canon RC-IP00 Remote Camera Controller User Manual - Page 17

Tally Setup, Tally Control Interface, Configuration method, Connection example for TALLY OUT

Page 17 highlights

Settings Tally Setup Tally Control Interface Configure the pin 4 and pin 5 functions of the tally terminal using the SETTING switch on the rear panel. Other than pin 4 and pin 5, the remaining pin functions cannot be changed. 1 5 6 9 12345678 ON . Memo : 0 If a camera has been selected to receive tally signals, the button corresponding to the camera appears like . Configuration method Tally terminal pin number Function 1 INPUT-1 2 INPUT-2 3 INPUT-3 4 INPUT-4 SETTING switch - 12345678 OUTPUT-5 ON . 12345678 ON . 5 INPUT-5 12345678 OUTPUT-4 ON . 12345678 ON . 6 GND - 7 OUTPUT-1 - 8 OUTPUT-2 - 9 OUTPUT-3 - Memo : 0 The tally input or tally output supports camera number 1 to 5 of camera group 1. To use the tally input or tally output, assign the cameras to these numbers. For details on the tally input and tally output, refer to the "Function" column of "Configuration method". 0 Inserting and removing of the tally terminal should be performed while the power is turned off. Connection example for TALLY OUT Please ensure the following conditions are met. Voltage : Maximum DC 24 V Current : Maximum 50 mA RC-IP100 (Maximum voltage 24 V) TALLY OUT (Maximum current 50 mA) LED GND . Connection example for TALLY IN Set up the contact input. RC-IP100 +5 V TALLY IN S G D GND . Tally Setup 17

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21

Tally Setup
Tally Control Interface
Configure the pin 4 and pin 5 functions of the tally terminal using
the SETTING switch on the rear panel.
Other than pin 4 and pin 5, the remaining pin functions cannot
be changed.
.
1
ON
2
3
4
5
6
7
8
1
6
5
9
Memo :
0
If a camera has been selected to receive tally signals, the
button corresponding to the camera appears like
.
Configuration method
Tally terminal pin
number
Function
SETTING switch
1
INPUT-1
-
2
INPUT-2
-
3
INPUT-3
-
4
INPUT-4
.
1
ON
2
3
4
5
6
7
8
OUTPUT-5
.
1
ON
2
3
4
5
6
7
8
5
INPUT-5
.
1
ON
2
3
4
5
6
7
8
OUTPUT-4
.
1
ON
2
3
4
5
6
7
8
6
GND
-
7
OUTPUT-1
-
8
OUTPUT-2
-
9
OUTPUT-3
-
Memo :
0
The tally input or tally output supports camera number 1 to 5
of camera group 1. To use the tally input or tally output, assign
the cameras to these numbers. For details on the tally input
and tally output, refer to the “Function” column of
"Configuration method".
0
Inserting and removing of the tally terminal should be
performed while the power is turned off.
Connection example for TALLY OUT
Please ensure the following conditions are met.
Voltage
:
Maximum DC 24 V
Current
:
Maximum 50 mA
.
RC-IP100
LED
TALLY OUT
(Maximum current
50 mA)
(Maximum voltage 24 V)
GND
Connection example for TALLY IN
Set up the contact input.
.
+5 V
TALLY IN
S
D
G
RC-IP100
GND
Tally Setup
17
Settings