Casio LK-270 MIDI Implementation - Page 39

Data Management Parameter

Page 39 highlights

23.2 Data Management Parameter These are information acquisition and operation command parameters for this Instrument's Data Manager PC application. Parameter ID R/W Block Size Array Min-Def-Max Description Ps Category Ps Memory Ps Number Ps Data Type 0005 W 000000 7 0006 W ↑ 7 0007 W ↑ 14 0008 R ↑ 8 Current Ps Existence 0009 R ↑ 1 Current Ps Protect 000A R ↑ 1 Current Ps Size 000B R ↑ 32 Current Sub Ps Size 000C R ↑ 32 Current Ps Name 000D R ↑ 8 Max Ps Size 000E R ↑ 32 Max Ps Number 000F R ↑ 14 Current Free Size 0010 R ↑ 32 Max Free Size 0011 R ↑ 32 Delete Ps 0012 W ↑ 1 01 00-00-7F Specifies the category ID of the parameter set that corresponds to an operation. 01 00-00-7F Specifies the memory ID of the parameter set that corresponds to an operation. 01 0000-0001-3FFF Specifies the number of the parameter set that corresponds to an operation. 01 00-00-FF This the data type of the parameter set in the specified category. Compatibility is provided between models with the same type. 01 00-00-01 Whether a parameter set exists in the specified category (0: No, 1: Yes). 01 00-00-01 Protect status of a parameter set data in the specified category (0: Off, 1: On). 01 00000000-00000000-FFFFFFFF Size of a parameter set in the specified category/ number (bytes). 01 00000000-00000000-FFFFFFFF Total size of a parameter sets under the specified category (bytes). 08 00-20-7F Name of a parameter set in the specified category (ASCII characters). 01 00000000-00000000-FFFFFFFF Maximum size of parameter sets in the specified category (bytes). 01 0000-0000-FFFF Maximum number parameter sets in the specified category (bytes). 01 00000000-00000000-FFFFFFFF Size of current parameter set free space in the specified category (bytes). 01 00000000-00000000-FFFFFFFF Maximum size of parameter free space in the specified category (bytes). 01 00-00-01 Deletes parameter sets in the specified category. Values are ignored. 39

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46

39
23.2
Data Management Parameter
These are information acquisition and operation command parameters for this Instrument's Data Manager PC application.
Parameter
ID R/W Block Size Array
Min-Def-Max
Description
Ps Category
0005
W
000000
7
01
00-00-7F
Specifies the category ID of
the parameter set that
corresponds to an operation.
Ps Memory
0006
W
7
01
00-00-7F
Specifies the memory ID of
the parameter set that
corresponds to an operation.
Ps Number
0007
W
14
01
0000-0001-3FFF
Specifies the number of the
parameter set that
corresponds to an operation.
Ps Data Type
0008
R
8
01
00-00-FF
This the data type of the
parameter set in the
specified category.
Compatibility is provided
between models with the same
type.
Current Ps Existence
0009
R
1
01
00-00-01
Whether a parameter set
exists in the specified
category (0: No, 1: Yes).
Current Ps Protect
000A
R
1
01
00-00-01
Protect status of a
parameter set data in the
specified category (0: Off,
1: On).
Current Ps Size
000B
R
32
01
00000000-00000000-FFFFFFFF
Size of a parameter set in
the specified category/
number (bytes).
Current Sub Ps Size
000C
R
32
01
00000000-00000000-FFFFFFFF
Total size of a parameter
sets under the specified
category (bytes).
Current Ps Name
000D
R
8
08
00-20-7F
Name of a parameter set in
the specified category
(ASCII characters).
Max Ps Size
000E
R
32
01
00000000-00000000-FFFFFFFF
Maximum size of parameter
sets in the specified
category (bytes).
Max Ps Number
000F
R
14
01
0000-0000-FFFF
Maximum number parameter
sets in the specified
category (bytes).
Current Free Size
0010
R
32
01
00000000-00000000-FFFFFFFF
Size of current parameter
set free space in the
specified category (bytes).
Max Free Size
0011
R
32
01
00000000-00000000-FFFFFFFF
Maximum size of parameter
free space in the specified
category (bytes).
Delete Ps
0012
W
1
01
00-00-01
Deletes parameter sets in
the specified category.
Values are ignored.