Dell Alienware Aurora R5 Aurora R5 Setup and Specifications - Page 16
Computer environment, Airborne contaminant level, Operating, Storage
View all Dell Alienware Aurora R5 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 16 highlights
Output current: Rated output voltage: 3.3V/17A, 5V/25A, 12VA/18A, 12VB/16A, 12VC/8A, 5Vaux/3A 3.3V, 5V, 12VA, 12VB, 12VC, 5Vaux 3.3V/20A, 5V/20A, 12VA/32A, 12VB/48A, 12VD/16A, -12V/0.5A, 5Vaux/4A 3.3V, 5V, 12VA, 12VB, 12VD, -12V, 5Vaux Computer environment Airborne contaminant level: G2 or lower as defined by ISA-S71.04-1985 Table 15. Computer environment Operating Temperature range 5°C to 35°C (41°F to 95°F) Relative humidity (maximum) 10% to 90% (non-condensing) Vibration (maximum) Shock (maximum)* 0.26 GRMS 40 G for 2 ms with a change in velocity of 20 in/s (51 cm/s)† Altitude (maximum) -15.20 m to 3048 m (-50 ft to 10,000 ft) Storage -40°C to 65°C (-40°F to 149°F) 0% to 95% (non-condensing) 1.37 GRMS 105 G for 2 ms with a change in velocity of 52.5 in/s (133 cm/s)‡ -15.20 m to 10,668 m (-50 ft to 35,000 ft) * Measured using a random vibration spectrum that simulates user environment. † Measured using a 2 ms half-sine pulse when the hard drive is in use. 16