controller, Z-Series, S4810, debug openflow packets
View all Dell Force10 Software Defined Networking manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 28 highlights
controller Specify the OpenFlow controller configuration that the OpenFlow instance uses to establish a connection. Z-Series, S4810 Syntax Parameter controller {controller-id}{ip-address}[port port-number]tcp controller-id ip-address port port-number Enter the controller number (must be 1). Enter the IP address of the controller. Enter the keyword port followed by the port number to use for the connection. Range is 1 to 65535. Defaults Command Modes Command History Default port number for the TCP connection is 6633. OPENFLOW INSTANCE Version 9.1(0.0) Introduced on Z9000 and S4810. Usage Information Related Commands The controller number must be entered as 1 to enable OpenFlow. Currently, only TCP connection is supported. openflow of-instance Create or modify an OpenFlow instance. debug openflow packets Enable debugging for OpenFlow packets. Z-Series, S4810 Syntax Parameter debug openflow packets {packet-type packet-type} of-instance {of-id} {packet-type packet-type} Enter the keyword packet-type followed by one of the following packet types: all barrier-reply barrier-request echo-reply echo-request error Enable debugging for all packets. Enable debugging for barrier-reply packets. Enable debugging for barrier-request packets. Enable debugging for echo-reply packets. Enable debugging for echo-request packets. Enable debugging for error packets. 28