Regulatory compliance The following table lists the regulatory compliance of your OptiPlex 7000 Small Form Factor. Table 23. Regulatory compliance Regulatory compliance Product Safety, EMC and Environmental Datasheets Dell Regulatory Compliance Home page Dell and the Environment Operating and storage environment This table lists the operating and storage specifications of your OptiPlex 7000 Small Form Factor. Airborne contaminant level: G1 as defined by ISA-S71.04-1985 Table 24. Computer environment Description Temperature range Operating 10°C - 35°C (50°F - 95°F) Storage -40°C-65°C (-40°F-149°F) Relative humidity (maximum) 20% to 80% (non-condensing, Max dew 5% to 95% (non-condensing, Max dew point temperature = 26°C) point temperature = 33°C) Vibration (maximum)* 0.26 GRMS random at 5 Hz to 350 Hz 1.37 GRMS random at 5 Hz to 350 Hz Shock (maximum) Bottom half-sine pulse with a change in 105G half-sine pulse with a change in velocity of 40.20 cm/sec (20 in./sec) velocity of 105.20 cm/sec (52.5 in./sec) Altitude range -15.2 m to 3048 m (-49 ft to 10,000 ft) -15.2 m to 10,668 m (-49 ft to 35,000 ft) CAUTION: Operating and storage temperature ranges may differ among components, so operating or storing the device outside these ranges may impact the performance of specific components. * Measured using a random vibration spectrum that simulates user environment. † Measured using a 2 ms half-sine pulse. Dell Support policy For information on Dell support policy, search in the Knowledge Base Resource at www.dell.com/support. Specifications of OptiPlex 7000 Small Form Factor 23

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

Regulatory compliance
The following table lists the regulatory compliance of your OptiPlex 7000 Small Form Factor.
Table 23. Regulatory compliance
Regulatory compliance
Product Safety, EMC and Environmental Datasheets
Dell Regulatory Compliance Home page
Dell and the Environment
Operating and storage environment
This table lists the operating and storage specifications of your OptiPlex 7000 Small Form Factor.
Airborne contaminant level:
G1 as defined by ISA-S71.04-1985
Table 24. Computer environment
Description
Operating
Storage
Temperature range
10°C – 35°C (50°F – 95°F)
-40°C-65°C (-40°F-149°F)
Relative humidity (maximum)
20% to 80% (non-condensing, Max dew
point temperature = 26°C)
5% to 95% (non-condensing, Max dew
point temperature = 33°C)
Vibration (maximum)
*
0.26 GRMS random at 5 Hz to 350 Hz
1.37 GRMS random at 5 Hz to 350 Hz
Shock (maximum)
Bottom half-sine pulse with a change in
velocity of 40.20 cm/sec (20 in./sec)
105G half-sine pulse with a change in
velocity of 105.20 cm/sec (52.5 in./sec)
Altitude range
-15.2 m to 3048 m (-49 ft to 10,000 ft)
-15.2 m to 10,668 m (-49 ft to 35,000
ft)
CAUTION:
Operating and storage temperature ranges may differ among components, so operating or storing
the device outside these ranges may impact the performance of specific components.
* Measured using a random vibration spectrum that simulates user environment.
† Measured using a 2 ms half-sine pulse.
Dell Support policy
For information on Dell support policy, search in the Knowledge Base Resource at
www.dell.com/support
.
Specifications of OptiPlex 7000 Small Form Factor
23