Dell PowerConnect 5448 Command Line Interface Guide - Page 125
clock summer-time, date month year hh:mm date month year hh:mm - save config
View all Dell PowerConnect 5448 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 125 highlights
Examples The following example sets the timezone to 6 hours difference from UTC. Console# (config)# clock timezone -6 zone CST clock summer-time The clock summer-time Global Configuration mode command configures the system to automatically switch to summer time (daylight saving time). Use the no form of this command to configure the software to not automatically switch to summer time. Syntax • clock summer-time recurring {usa | eu | {week day month hh:mm week day month hh:mm}} [offset offset] [zone acronym] • clock summer-time date date month year hh:mm date month year hh:mm [offset offset] [zone acronym] • clock summer-time date month date year hh:mm month date year hh:mm [offset offset] [zone acronym] • no clock summer-time • recurring - Indicates that summer time should start and end on the corresponding specified days every year. • date - Indicates that summer time should start on the first specific date listed in the command and end on the second specific date in the command. • usa - The summer time rules are the United States rules. • eu - The summer time rules are the European Union rules. • week - Week of the month. (Range: 1 - 4, first, last) • day - Day of the week. (Range: first three letters by name, like sun) • date - Date of the month. (Range:1 - 31) • month - Month. (Range: first three letters by name) • year - year - no abbreviation. (Range: 2000 - 2097) • hh:mm - Time in military format, in hours and minutes. (Range: hh: 0 - 23, mm:0 - 59) • offset offset - Number of minutes to add during summer time. (Range: 1 - 1440) • zone acronym - The acronym of the time zone to be displayed when summer time is in effect. If unspecified default to the timezone acronym. (Range: Up to 4 characters) Clock 125