reserved. Reproduction in any manner whatsoever without the written permission of Dell Computer Corporation is strictly forbidden. Trademarks used in this text: Dell, the DELL E COM logo, and PowerEdge are trademarks of Dell Computer Corporation; Intel and Pentium are registered trademarks of Intel - Dell PowerEdge 2300 | Dell PowerEdge Systems Microprocessor Upgrade Guide - Page 3
the BIOS 1-4 Saving RCU Configuration Settings 1-4 Installing Upgrade Microprocessors in the PowerEdge 1300 1-4 Installing Upgrade Microprocessors in the PowerEdge 2300 1-6 Installing Upgrade Microprocessors in the PowerEdge 4300 1-8 Installing Upgrade Microprocessors in the PowerEdge 4350 - Dell PowerEdge 2300 | Dell PowerEdge Systems Microprocessor Upgrade Guide - Page 4
iv - Dell PowerEdge 2300 | Dell PowerEdge Systems Microprocessor Upgrade Guide - Page 5
basic input/output system (BIOS) revision and saving the current configuration data Accessing the system board (see your system's Installation and Troubleshooting Guide) Replacing the system board mounting plate or tray (PowerEdge 2300 and 4300) Installing the upgrade microprocessor Installing the - Dell PowerEdge 2300 | Dell PowerEdge Systems Microprocessor Upgrade Guide - Page 6
kit will vary, depending on the PowerEdge system and the number of microprocessors you are installing. Each kit will have one or more new Pentium II or Pentium III microprocessor(s), diskettes containing the Resource Configuration Utility (RCU), BIOS, embedded server management (ESM) firmware, and - Dell PowerEdge 2300 | Dell PowerEdge Systems Microprocessor Upgrade Guide - Page 7
the instructions on the screen. 4. After the Successfully Completed Done message appears on the screen, remove the ESM firmware diskette from the diskette drive and follow the instructions on the screen to reboot the system. support.dell.com Dell PowerEdge Systems - Microprocessor Upgrade 1-3 - Dell PowerEdge 2300 | Dell PowerEdge Systems Microprocessor Upgrade Guide - Page 8
and peripheral cables. b. Removing the covers. c. Rotating the power supply. See your system Installation and Troubleshooting Guide for instructions. 2. Remove the microprocessors. See "Removing the Microprocessors", found later in this document. 1-4 Dell PowerEdge Systems - Microprocessor Upgrade - Dell PowerEdge 2300 | Dell PowerEdge Systems Microprocessor Upgrade Guide - Page 9
the System Setup program by changing Chassis Intrusion to Not Detected. NOTE: If a setup password has been assigned by someone else, contact your network administrator for information on resetting the chassis intrusion detector. support.dell.com Dell PowerEdge Systems - Microprocessor Upgrade 1-5 - Dell PowerEdge 2300 | Dell PowerEdge Systems Microprocessor Upgrade Guide - Page 10
d. Removing the cooling fan shroud. e. Replacing the system board mounting plate or tray. Applies only when installing 600 MHz or greater microprocessors. See your system Installation and Troubleshooting Guide for specific instructions, if needed. 1-6 Dell PowerEdge Systems - Microprocessor Upgrade - Dell PowerEdge 2300 | Dell PowerEdge Systems Microprocessor Upgrade Guide - Page 11
the system board. f. At the left side of the system, locate and remove the three screws that secure the system board and mounting plate to the chassis (see Figure 1-1). mounting screws (3) system board and mounting-plate assembly support.dell.com Dell PowerEdge Systems - Microprocessor Upgrade - Dell PowerEdge 2300 | Dell PowerEdge Systems Microprocessor Upgrade Guide - Page 12
plate assembly (provided in your upgrade kit) in your PowerEdge 2300 system, perform the preceding steps in reverse order. 4. Remove the microprocessor. See "Removing the Microprocessors", found later in this document. 5. Remove the cooling shroud. See "Removing and Replacing the Cooling Shroud - Dell PowerEdge 2300 | Dell PowerEdge Systems Microprocessor Upgrade Guide - Page 13
the upgrade mounting tray assembly (provided in your upgrade kit) in your PowerEdge 4300 system, perform the preceding steps in reverse order. 3. Remove the microprocessors. See "Removing the Microprocessors", found later in this document. support.dell.com Dell PowerEdge Systems - Microprocessor - Dell PowerEdge 2300 | Dell PowerEdge Systems Microprocessor Upgrade Guide - Page 14
Install the upgrade microprocessor. See "Installing the Upgrade Microprocessor", found later in this document. 6. Reassemble and check the system. See "Reassembling and Checking the System", found later in this document. system board tray 1-10 Dell PowerEdge Systems - Microprocessor Upgrade tray - Dell PowerEdge 2300 | Dell PowerEdge Systems Microprocessor Upgrade Guide - Page 15
a. Disconnecting power and peripheral cables. b. Removing the covers. c. Removing the front bezel. d. Removing the cooling fan shroud. See your system Installation and Troubleshooting Guide for specific instructions, if needed. support.dell.com Dell PowerEdge Systems - Microprocessor Upgrade 1-11 - Dell PowerEdge 2300 | Dell PowerEdge Systems Microprocessor Upgrade Guide - Page 16
cartridge 2 (SECC2) package is different. 3. Grasp the microprocessor assembly firmly and pull it away from the microprocessor guide bracket assembly. You must use up to 15 pounds (lb) of force to disengage the microprocessor from the connector. 1-12 Dell PowerEdge Systems - Microprocessor Upgrade - Dell PowerEdge 2300 | Dell PowerEdge Systems Microprocessor Upgrade Guide - Page 17
over the four threaded posts (see Figure 1-6). You can install the guide bracket only one way (the captive nuts will not align with the threaded posts if installed incorrectly). 2. Tighten the four captive nuts using a #2 Phillips screwdriver. Dell PowerEdge Systems - Microprocessor Upgrade 1-13 - Dell PowerEdge 2300 | Dell PowerEdge Systems Microprocessor Upgrade Guide - Page 18
guide bracket assembly threaded posts (4) guide bracket assembly captive nuts (4) system board connector captive nuts (4) threaded posts (4) system board connector 1-14 Dell PowerEdge Systems - Microprocessor Upgrade - Dell PowerEdge 2300 | Dell PowerEdge Systems Microprocessor Upgrade Guide - Page 19
remove the two retention pins (see Figure 1-7). 4. Remove the shroud by lifting the end of the shroud closest to the microproces- sor(s) until the opposite end of the shroud disengages from the cooling fan on the system back panel. support.dell.com Dell PowerEdge Systems - Microprocessor Upgrade - Dell PowerEdge 2300 | Dell PowerEdge Systems Microprocessor Upgrade Guide - Page 20
the large opening on the end of the cooling shroud over the top of the cooling fan on the system back panel. 2. Lower the other end of the shroud into place over the microprocessor(s). 3. Secure the shroud by reinstalling the two retention pins. 1-16 Dell PowerEdge Systems - Microprocessor Upgrade - Dell PowerEdge 2300 | Dell PowerEdge Systems Microprocessor Upgrade Guide - Page 21
shown in Figure 1-8. 3. Repeat steps 1 and 2 for your second upgrade microprocessor or to install a terminator card. install this retention pin after the cooling shroud is installed on PowerEdge 2300 systems only threaded stud support.dell.com Dell PowerEdge Systems - Microprocessor Upgrade 1-17 - Dell PowerEdge 2300 | Dell PowerEdge Systems Microprocessor Upgrade Guide - Page 22
microprocessor upgrade kit and your system is a PowerEdge 1300 or PowerEdge 2300, you must install the cooling shroud provided in the upgrade kit. To install a cooling shroud, perform the following steps: 1. Carefully position the shroud into place with the square opening over the bulk- head fan and - Dell PowerEdge 2300 | Dell PowerEdge Systems Microprocessor Upgrade Guide - Page 23
the new microprocessor is operating correctly. See your User's Guide and your Installation and Troubleshooting Guide for additional information on running the Dell Diagnostics and troubleshooting any problems that may occur. support.dell.com Dell PowerEdge Systems - Microprocessor Upgrade 1-19 - Dell PowerEdge 2300 | Dell PowerEdge Systems Microprocessor Upgrade Guide - Page 24