Dell PowerEdge C8000 Dell PowerEdge C8220 Hardware Owner's Manual
Dell PowerEdge C8000 Manual
View all Dell PowerEdge C8000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Dell PowerEdge C8000 manual content summary:
- Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 1
Dell PowerEdge C8220 Hardware Owner's Manual Regulatory Model: B05B Regulatory Type: B05B001 - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 2
A CAUTION indicates potential damage to hardware or loss of data if instructions are not followed. WARNING: A WARNING indicates a potential for property permission of Dell Inc. is strictly forbidden. Trademarks used in this text: Dell™, the DELL logo, and PowerEdge™ are trademarks of Dell Inc. Intel - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 3
11 Accessing System Features During Startup 11 Front-Panel Features and Indicators 12 NIC Indicator Codes 14 Power and System Board Indicator Codes 16 BMC Heartbeat Indicator Codes 17 Service Tag 18 POST Error Code 19 Collecting System Event Log for Investigation 19 System Event Log 27 - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 4
and Configuring Console Redirection 47 Serial Port Connection List 51 Main Menu 52 Main Screen 52 System Settings 53 Advanced Menu 55 Power Management 56 CPU Configuration 62 Memory Configuration 65 SATA Configuration 67 PCI Configuration 70 USB Configuration 77 Security Menu 78 - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 5
List 113 Power Management Settings 122 3 Installing System Components 125 Safety Instructions 125 Recommended Tools 126 Inside the System 127 Sled Configuration 128 Sled 129 Removing a Sled 129 Installing a Sled 130 Sled Blank 130 Removing a Sled Blank 130 Installing a Sled Blank 131 - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 6
a Heat Sink 139 Processors 140 Removing a Processor 140 Installing a Processor 142 System Memory 143 Memory Module Installation Guidelines 143 Supported DIMM Configuration 144 Removing Memory Modules 146 Installing Memory Modules 147 Expansion Card 148 Removing the Expansion Card 148 - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 7
the SD Card Reader 160 Removing the SD Card Reader Support Bracket 161 Installing the SD Card Reader Support Bracket 162 Internal Hard-Drives 162 Removing a Hard- 168 Node Power Distribution Board 169 Removing the Node Power Distribution Board 169 Installing the Node Power Distribution Board - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 8
a NIC 180 Troubleshooting a Wet Enclosure 181 Troubleshooting a Damaged Enclosure 182 Troubleshooting the Enclosure Fan Modules . . . . . 183 Troubleshooting the Power Sled 185 Troubleshooting System Memory 185 Troubleshooting a Hard-Drive 187 Troubleshooting a Storage Controller 188 - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 9
5 Jumpers and Connectors 195 System Board Jumper Settings 195 System Board Connectors 197 Interposer Extender Connectors 199 SD Card Reader Connectors 200 Node Power Distribution Board Connectors 201 6 Getting Help 203 Contacting Dell 203 Index 205 Contents 9 - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 10
10 Contents - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 11
System Accessing System Features During Startup The following keystrokes provide access to system features during startup. The SAS/SATA card or PXE hotkey support are available only in the BIOS boot mode. Hotkey function is not available in the Unified Extensible Firmware Interface (UEFI) boot mode - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 12
devices to the system. The ports are USB 2.0 compliant. Installs an I/O module mezzanine card. Installs a low profile PCI Express x16 card. Press to release the sled from the enclosure. 12 About Your System - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 13
: On ACPI-compliant operating systems, turning off the sled using the power button causes the sled to perform a graceful shutdown before power to the sled is turned off. NOTE: To force an ungraceful particular system and system board. Hold to pull the sled from the enclosure. About Your System 13 - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 14
NIC Indicator Codes Figure 1-2. NIC Indicators 1 link indicator 2 activity indicator Indicator Status Link indicator Solid amber Solid green Blinking green Activity indicator Off Solid green Blinking green Off Indicator Code Linking at 100 Mbps port speed Linking at 1 Gbps port speed ( - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 15
Figure 1-3. NIC Indicators (BMC management port) 1 link indicator 2 activity indicator Indicator Status Link indicator Blinking amber Blinking green Activity indicator Solid green Blinking green Off Indicator Code Linking at 10 Mbps port speed Linking at 100 Mbps port speed (maximum) No - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 16
Off Status Solid Off Solid Blinking Blinking Blinking Solid Blinking Indicator Code Sled power is on (S0) BMC critical condition event in power off mode (S4/S5) BMC critical condition event in power on mode (S0) The IPMI via Chassis Identify Command On or ID Button Press ID On is generated. Only - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 17
a BMC heartbeat indicator (LED17) for debugging the Baseboard Management Controller (BMC). The BMC heartbeat indicator lights green when power is supplied to the sled and blinks green when the BMC firmware is ready. Figure 1-4. BMC Heartbeat Indicator 1 system board 2 BMC heartbeat indicator - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 18
Service Tag The following illustration provides location of the Service Tag number on the C8220 single-wide compute sled. Figure 1-5. Service Tag Location for C8220 Single-Wide Compute Sled 18 About Your System - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 19
Error Video device initialization failed Corrective Actions See "Troubleshooting the Video Subsystem" on page 178. If the problem persists, see "Getting Help" on page 203. See "Troubleshooting the Video Subsystem" on page 178. If the problem persists, see "Getting Help" on page 203. About - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 20
see "Getting Help" on page 203. See "Troubleshooting Expansion Cards" on page 189. If the problem persists, see "Getting Help" on page 203. See "Troubleshooting a USB Device" on page 178. If the problem persists, see "Getting Help" on page 203. See "Troubleshooting a USB Device" on page 178. If the - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 21
page 203. To enable USB device, see "USB Configuration" on page 77. See "Troubleshooting a USB Device" on page 178. If the problem persists, see "Getting Help" on page 203. See "Troubleshooting a USB Device" on page 178. If the problem persists, see "Getting Help" on page 203. About Your System 21 - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 22
the the keyboard to the compute sled. If the problem persists, see "Getting Help" on page 203. Memory Remove AC power to the correctable system for 10 seconds and error detected restart the system. See "Troubleshooting System Memory" on page 185. If the problem persists, see "Getting Help" on - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 23
Getting Help" on page 203. See "Troubleshooting Expansion Cards" on page 189. If the problem persists, see "Getting Help" on page 203. See "Troubleshooting Expansion Cards" on page 189. If the problem persists, see "Getting Help" on page 203. See "Troubleshooting a Serial I/O Device" on page 179. If - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 24
type described in the processor technical specifications outlined in your system's Getting Started Guide. SATA 0 device not found Check if the SATA port 0 is enabled. See "SATA Configuration" on page 67. Install a SATA device to SATA port 0. If the problem persists, see "Getting Help" on - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 25
device not found Check if the SATA port 5 is enabled. See "SATA Configuration" on page 67. Install a SATA device to SATA port 5. If the problem persists, see "Getting Help" on page 203. Memory Sparing Mode Failed Check if the memory configuration is set to Sparing mode. See "Memory Configuration - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 26
Actions Pause Pause Supervisor and Reset password. See "System User Passwords Board Jumper Settings" on have been page 195. cleared If the problem persists, see "Getting Help" on page 203. No CMOS battery See "Troubleshooting the System Battery" on page 192. 26 About Your System - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 27
System Event Log Processor Error Message: "Processor Sensor, IERR error, Processor 1" Table 1-2. Processor Error Byte Field 1 NetFunLun 2 Platform Event Command 3 Generator ID 4 Event Message Format Version 5 Sensor Type 6 Sensor Number Value 10h 02h 01h 04h 07h 04h 7 Event - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 28
Memory Ecc Message: "Memory Sensor, Correctable ECC error, SBE warning threshold, CPU1 DIMM_A1" Table 1-3. Memory ECC Byte Field 1 NetFunLun 2 Platform Event Command 3 Generator ID 4 Event Message Format Version 5 Sensor Type 6 Sensor Number 7 Event Direction Event Type 8 Event - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 29
Table 1-3. Memory ECC Byte Field 9 Event Data2 10 Event Data3 Value XXh XXh Description Bit 7:4 0x00: SBE warning threshold 0x01: SBE critical threshold 0x0F: Unspecified Bit 3:0 0x00: CPU1 DIMM A1-8 slots (1~8) 0x01: CPU2 DIMM B1-8 slots (9~16) 0x02: CPU3 DIMM C1-8 slots (17~24) 0x03: CPU4 - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 30
PCIe Error Message: "Critical Interrupt Sensor, PCI PERR, Device#, Function#, Bus# " Table 1-4. PCIe Error Byte Field 1 NetFunLun 2 Platform Event Command 3 Generator ID 4 Event Message Format Version 5 Sensor Type 6 Sensor Number 7 Event Direction Event Type 8 Event Data1 9 - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 31
IOH Core Error Message: "Critical Interrupt Sensor, Fatal Error, xxxx bit, QPI[0] Error " Table 1-5. IOH Core Error Byte Field 1 NetFunLun 2 Platform Event Command 3 Generator ID 4 Event Message Format Version 5 Sensor Type 6 Sensor Number 7 Event Direction Event Type 8 Event - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 32
SB Error Message: "Critical Interrupt Sensor, Correctable, MCU Parity Error " Table 1-6. SB Error Byte Field 1 NetFunLun 2 Platform Event Command 3 Generator ID 4 Event Message Format Version 5 Sensor Type 6 Sensor Number 7 Event Direction Event Type 8 Event Data1 9 Event Data2 - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 33
POST Start Event Message: "System Event, POST starts with BIOS xx.xx.xx" Table 1-7. POST Start Event Byte Field 1 NetFunLun 2 Platform Event Command 3 Generator ID 4 Event Message Format Version 5 Sensor Type 6 Sensor Number 7 Event Direction Event Type 8 Event Data1 9 Event - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 34
(Legacy) 1b: uEFI Boot Bit 3:0 = Boot Device 0001b: Force PXE Boot 0010b: NIC PXE Boot 0011b: Hard Disk Boot 0100b: RAID HDD Boot 0101b: USB Storage Boot 0111b: CD/DVD ROM Boot 1000b: iSCSI Boot 1001b: uEFI Shell 1010b: ePSA Diagnostic Boot FFh: Not Present 34 About Your System - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 35
POST Error Code Event Message: "System Firmware Progress, POST error code: UBLBh." Table 1-9. POST Error Code Event Byte Field 1 NetFunLun 2 Platform Event Command 3 Generator ID 4 Event Message Format Version 5 Sensor Type 6 Sensor Number 7 Event Direction Event Type 8 Event - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 36
BIOS Recovery Event Table 1-10. BIOS Recovery Event Byte Field 1 NetFunLun 2 Platform Event Command 3 Generator ID 4 Event Message Format Version 5 Sensor Type 6 Sensor Number 7 Event Direction Event Type 8 Event Data1 9 Event Data2 10 Event Data3 Value 10h 02h 01h 04h 12h - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 37
ME Fail Event Table 1-11. BIOS Recovery Event Byte Field 1 NetFunLun 2 Platform Event Command 3 Generator ID 4 Event Message Format Version 5 Sensor Type 6 Sensor Number 7 Event Direction Event Type 8 Event Data1 9 Event Data2 10 Event Data3 Value 10h 02h 01h 04h 12h 8Ah 6Fh - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 38
BMC The following table includes an overview of the system sensors. In the Offset column: • SI = Sensor Initialization • SC = Sensor Capabilities • AM = Assertion Mask • DM = Deassertion Mask • RM = Reading Mask • TM = Settable/Readable Threshold Mask Table 1-13. Sensor Summary Sensor Sensor Name - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 39
Table 1-14. Sensor Summary (continued) Sensor Sensor Name Number 04h CPU ERR2 Sensor Type Processor (07h) 05h 12V Standby Voltage (02h) 06h 5V Voltage (02h) 07h 5V Standby Voltage (02h) 08h 3.3V Voltage (02h) Event/Reading Type Offset Sensor-specific (6Fh) Threshold (01h) Threshold - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 40
Table 1-15. Sensor Summary (continued) Sensor Sensor Name Number 09h 3.3V Standby 0Ah Battery low 41h MEZZ1 TEMP 41h CPU1 Temp 42h CPU2 Temp Sensor Type Voltage (02h) Battery (29h) Temperature (01h) Temperature (01h) Temperature (01h) Event/Reading Type Threshold (01h) Sensor-specific ( - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 41
Table 1-16. Sensor Summary (continued) Sensor Sensor Name Number Sensor Type 43h DIMM ZONE 1 Temperature (01h) Temp 44h DIMM ZONE 1 Temperature (01h) Temp 45h PCH Temp Temperature (01h) 60h Memory Memory (0Ch) A0h Watchdog Watchdog 2 (23h) Event/Reading Type Threshold (01h) - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 42
17. Sensor Summary (continued) Sensor Sensor Name Number A1h Soft Reset Sensor Type System Boot/ Restart Initiated (1Dh) A2h AC lost Power Unit (09h) A3h Power off Power Unit (09h) Event/Reading Type Offset Sensor-specific (6Fh) Sensor-specific (6Fh) Sensor-specific (6Fh) SI: 01h SC: 40h AM - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 43
, and technical specifications. • The PowerEdge C8000 Hardware Owner's Manual for information about the server enclosure features, troubleshooting, and component replacement.. This document is available at support.dell.com/manuals. • The Baseboard Management Controller Guide provides information - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 44
44 About Your System - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 45
system security System Setup Menu The system employs the latest Insyde® BIOS, which is stored in Flash memory. The Flash memory supports the Plug and Play specification, and contains a System Setup program, the Power On Self Test (POST) routine, and the PCI auto-configuration utility. This system - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 46
• When changing the password or making other changes to the security setup NOTE: Only items in brackets [ ] can be modified, Items that are not in brackets are display only. System Setup Options at Boot You can initiate Setup by pressing the respective key during the POST: Keystroke - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 47
a remote user to diagnose and fix problems on a server, which has not successfully booted the supports console redirection to a serial port. If serial port based headless server support is provided by the system, the system must provide support on the system. • External serial port • Internal serial - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 48
See Figure 1-1 for the location of the serial port on the sled. 2 Press immediately after a power-on or reboot to enter System Setup. 3 In the System Setup screen, select the Server menu and press . 4 In the Server screen, select Remote Access Configuration and press . 48 Using - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 49
1-1 for the location of the BMC management port on the sled. 2 Press immediately after a power-on or reboot to enter System Setup. 3 In the System Setup screen, select the Server menu and press . 4 In the Server screen, select Remote Access Configuration and press . 5 In the - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 50
Figure 1-1 for the location of the Ethernet connector 1 on the sled. 2 Press immediately after a power-on or reboot to enter System Setup. 3 In the System Setup screen, select the Server menu and press . 4 In the Server screen, select Remote Access Configuration and press . 5 In - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 51
See "Remote Access Configuration" on page 83 for details. Make sure the last four options syncs with the host and client. 6 In the Server screen, select BMC LAN Configuration and press . 7 In the BMC LAN Configuration screen, verify the following settings: • BMC LAN Port Configuration: Shared - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 52
Main Menu The main menu displays information about your system boards and BIOS. Main Screen NOTE: Press to enter the BIOS debug mode and reset the BIOS to default settings. NOTE: The options for the System Setup program change based on the system configuration. NOTE: The System Setup - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 53
number when updating BIOS from the manufacturer. Displays the date the BIOS was created. Displays the system service tag number. The service tag field should match what is physically on the service tag of the system. Displays the system asset tag number. Displays the Memory Reference Code (MRC - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 54
Option Description System Memory Speed Displays the maximum speed of your system memory. System Memory Voltage Displays the maximum voltage of your system memory. 54 Using the System Setup Program - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 55
Advanced Menu The advanced menu displays a table of items that defines advanced information about your system. Scroll to this item and press to view the following screen. CAUTION: Making incorrect settings to items on these pages may cause the system to malfunction. Unless you have - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 56
operating system to control the power management. • Node Manager: Enables Node Manager to moderate power consumption and performance of the processors in the compute sled. Node manager delivers power reporting and power capping functionality for individual compute sleds. 56 Using the System Setup - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 57
Offers full performance and saves power by reducing system power consumption during periods of inactivity. • Low Power: Use different processor power saving modes (C-states) to reduce system power consumption. NOTE: This option works when the OS does not support power management control of processor - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 58
the chassis power supply. This option provides management and monitoring of the PSUs and allows you to set the minimum PSU requirements for the server. Power Capping Press to set PSU power and server loading limited in selected watts. Emergency Throttling Press to set sled level - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 59
view the following screen. Chassis PSU Configuration Option Description Required Power Supplies Select the number of power supplies to provide load-shared (1 default) power to run the sleds in the enclosure. Options are [1], [2], [3], and [4]. Redundant Power Supplies (1 default) Select the - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 60
and press to view the following screen. Power Capping Option Chassis Level Capping (Disabled default) Sled Power Capping (0 default) Description Enables or disables chassis level capping. Specify the maximum amount of power to be consumed by the sled. Settings range from 0 or 100 to 1000 - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 61
emergency throttle event (Chassis Level default) is triggered. • Chassis Level: Overrides the chassis level policy for a specific server. • Throttling: Allows compute sled throttling when an emergency throttle event is triggered. • Power Off: Turns off the compute sled when an emergency throttle - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 62
throttle event is triggered. This option can be configured when the Sled Level Policy is set as Chassis Level. • Throttling: Allows chassis sled throttling when an emergency throttle event is triggered. • Power Off: The server power turns off when an emergency throttle event is triggered. CPU - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 63
is (NT4), fails if the value returned in EAX is >3 when CPUID instruction is executed with EAX=0. When enabled, this setting limits CPUID function to 3. enabled, the processor(s) can operate in all available power C states. When disabled, the user power C states are not available for the processor. - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 64
Option Direct Cache Access (Enabled default) Hyper-Threading Technology (Enabled default) Prefetch Configuration Description Enables or disables the direct cache access. Enables or disables the Hyper-Threading technology. Press to configure the prefetch settings. Prefetch Configuration - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 65
Option Hardware Prefetcher (Enabled default) DCU Streamer Prefetcher (Enabled default) DCU IP Prefetcher (Enabled default) Description Enables or disables the speculative unit within the processor(s). Enables or disables Data Cache Unit (DCU) streamer prefetcher. Enables or disables DCU IP - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 66
) Memory Operating Mode (Optimizer Mode default) Demand Scrubbing (Enabled default) Patrol Scrubbing (Enabled default) Memory Operating Voltage (Auto default) NUMA Support (Enabled default) Description Enables or disables the memory turbo mode. Enables or disables the memory to run in closed-loop - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 67
SATA Configuration Scroll to this item and press to view the following screen. Using the System Setup Program 67 - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 68
maximum 6.0 Gbps. • 1.5 Gbps: Sets the SATA link speed to 1.5 Gbps. For power consumption. • 3.0 Gbps: Sets the SATA link speed to 3.0 Gbps. When set to the 1st Serial ATA drive controller. When set to auto, enables BIOS support for the 1st Serial ATA drive controller (enabled if present, POST error - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 69
turns off the 3rd Serial ATA drive controller. When set to auto, enables BIOS support for the 3rd Serial ATA drive controller (enabled if present, POST error if not the feature that allows SATA harddrives to initiate link power management transitions. Enables or disables the hard-drive security freeze - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 70
PXE boot on NICs to boot the system. • Add-in: Use the PXE boot on add-in network adapters to boot the system. Active State Power Press to configure power management for Management Configuration PCI Express devices. 70 Using the System Setup Program - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 71
. NOTE: When you install a MIC GPGPU card in the C8220X sled, BIOS automatically enables the PCI memory 64-bit decode option. PCIe Generation Depending on the BIOS search order and system slot layout. WHEA Support (Disabled default) Enables or disables the Windows Hardware Error Architecture - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 72
Embedded Network Devices Scroll to this item and press to view the following screen. 72 Using the System Setup Program - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 73
PXE or RPL boot-ROM are disabled in this option. • iSCSI Remote Boot: Allows you to configure the iSCSI target and initiator variables to support iSCSI Remote Boot. Changes take effect after the system reboots. • Disabled: Allows you to disable the system's primary embedded NIC. iSCSI Remote Boot - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 74
Option Gateway Target IP Target IP Address Target Port Boot LUN CHAP Type (None default) Description Sets the IP gateway for the static IP address. Sets the name for the target IP. Sets the target's IP address. Sets the target port. Sets the hexadecimal representation of LU number. Select CHAP type - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 75
Scroll to this item and press to view the following screen. Active State Power Management Configuration Option Description PCIe Slot ASPM (Disabled default) Select an active state power management (ASPM) protocol for the PCI Express slot. Options are [Disabled], [L0], [L1], [L0 - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 76
Enables or disables the PCIe slot1. Options are [Disabled], [Enabled], [Enabled without OPROM]. NOTE: When you install a MIC GPGPU card in the C8220X sled, BIOS automatically enables the PCI memory 64-bit decode option. You can set the GPGPU information using IPMI commands. See Table 2-18 for more - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 77
(Enabled default) Enables or disables internal USB port with BMC support. External USB Port1 (Enabled default) Enables or disables the external USB port1. External USB Port2 (Enabled default) Enables or disables the external USB port2. Internal USB Connector Enables or disables the internal - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 78
Security Menu The security menu enables you to set the security parameters. Scroll to this item and press to view the following screen. Security Settings Option Supervisor Password User Password Description Indicates whether a supervisor password has been set. If the password has been - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 79
Option Change Supervisor Change User Password Description You can install a Supervisor password, and if you install a supervisor password, you can then install a user password. A user password does not provide access to many of the features in the Setup utility. Note, the Change User Password - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 80
enables you to configure compute sled parameters. Scroll to this item and press to view the following screen. Server Settings Option Status of BMC IPMI Specification Version BMC Firmware Version NIC1 MAC Address NIC2 MAC Address Description Displays BMC status. Displays the Intelligent - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 81
Log Event Logging (Enabled default) NMI on Error (Enabled default) Description When enabled, BIOS enables Advanced Configuration and Power Interface (ACPI) Service Processor Management Interface (SPMI) table for IPMI driver installation. When disabled, BIOS disables the ACPI SPMI table for BMC - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 82
Set BMC LAN Configuration Scroll to this item and press to view the following screen. Set BMC LAN Configuration Option Description Channel Number Displays the channel number used for BMC LAN. Channel Number Status Displays the BMC channel number status. BMC LAN Port Configuration ( - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 83
Gateway Address IPv6 Mode (Disabled default) Description Sets the IP gateway for the static IP address. Enables or disables the IPv6 internet protocol support. If set to enabled, configure the IPv6 prefix, IP and gateway addresses. Remote Access Configuration Scroll to this item and press - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 84
115200 8,n,1 as default) Flow Control (None default) Redirection After BIOS POST (Always default) Terminal Type (ANSI default) VT-UTF8 Combo Key Support (Enabled default) Description Select a serial port for console redirection. • COM1: Enables console redirection via COM1. See token D7h. • COM2 as - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 85
View System Log Scroll to this item and press to view the following screen. View System Log Option View BMC SEL Event Log Clear BMC SEL Event Log Description View all events in the BMC system event log. Deletes all records in the BMC system event log. Using the System Setup Program 85 - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 86
Boot Menu The boot menu enables you to set POST boot parameters. Scroll to this item and press to view the following screen. Boot Settings Option Quiet Boot (Enabled default) Pause on Errors (Disabled default) Force PXE Boot only (Disabled default) Description Enable this item to display - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 87
Option Boot Mode (BIOS default) Boot Type Order Legacy Boot Device Description Select a system boot mode. • BIOS: The standard BIOS-level boot interface • UEFI: An enhanced 64-bit boot interface based on Unified Extensible Firmware Interface (UEFI) specifications that overlays the system BIOS. - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 88
Exit Menu Scroll to this item and press to view the following screen. Exit Options Option Save Changes and Exit Discard Changes and Exit Description Highlight this item and press to save any changes that you have made in the Setup utility and exit the Setup utility. When the Save - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 89
Option Description Save Changes Select this item and press to save changes you have made without leaving the setup utility. Discard Changes Select this item and press to discard any changes you have made without leaving the setup utility. Load Optimal Defaults If you highlight - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 90
is included in the Dell OpenManage Deployment Toolkit (DTK). See the Deployment Toolkit Version 1.3 User's Guide for additional information about installing For the next system boot, set the IPL priority to: USB storage, hard disk, CD/DVD-ROM, RAID, Network (if the devices are available). - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 91
system boot, set the IPL priority to: CD/DVD-ROM, USB Storage, hard disk, RAID, Network (if the devices are available). N/A Power Loss System remains off until the power button is pressed. Restore on AC Power Loss System reverts to the last power state before power loss. Restore on AC Power - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 92
Power Button Enables the power button to turn off the system power. (default) Power Button Disables the power button to turn off the system power Turns off the 2nd Serial ATA drive controller. SATA Port1 Enables BIOS support for the 2nd Serial ATA drive controller (enabled if present, POST error - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 93
0120 0121 0122 0135 0137 0138 0139 013E Setup Option Description SATA Port2 Turns off the 3rd Serial ATA drive controller. SATA Port2 Enables BIOS support for the 3rd Serial ATA drive controller (enabled if present, POST error appears if not present). SATA Port3 Turns off the 4th Serial ATA - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 94
in applicable processors. Allows you to electrically disable the external USB connector 1. Allow you to electrically enable the external USB connector 1. Some OS, which is (NT4), fails if the value returned in EAX is >3 when CPUID instruction is executed with EAX=0. This setting disables the 3 or - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 95
01C4 01C5 01C4 01C5 01CF 01D0 Setup Option Hardware Prefetcher Hardware Prefetcher Remote Access External USB PORT2 External USB PORT2 Power Saving Features Power Saving Features NUMA Support NUMA Support Node Interleave Node Interleave I/OAT DMA Engine I/OAT DMA Engine Description Disables the - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 96
Enables Intel Virtualization Technology for Direct I/O (VT-d) that enhances I/O support (DMA) when running a Virtual Machine Monitor. Internal USB PORT Enables the internal USB connector. Maximum Performance Sets the system power management to maximum performance. OS Control Allows the OS to - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 97
legacy mode, ensures compatibility with operating systems that do not support UEFI. Active Processor Four cores of the processor are enabled Core processors. C States When enabled, the processor can operate in all available Power C States. (default) C States When disabled, there are no C states - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 98
C1E State C1E State Description Selects Advanced ECC (i.e. Lockstep, Chipkill) as the memory operating mode. Sets to support HyperTransport 1 specification. Sets to support HyperTransport 3 specification. This field controls the number of enabled all of cores in each processor. By default, the - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 99
default) SR-IOV Global Enables BIOS support for SRIOV devices. Enable SR-IOV Global Disables BIOS support for SRIOV devices. Enable Memory Indicates Streamer Prefetcher. Prefetcher Data Reuse Optimization Sets to enable for HPC applications. (default) Data Reuse Optimization Sets to disable - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 100
Table 2-1. D4 Token Table (continued) Token 02CA 02CE 02CF 401A 401B 401C 401D 4022 4026 Setup Option Description QPI Bandwidth Sets to I/O for I/O-intensive applications. Priority DCU IP Prefetcher Enables the DCU IP Prefetcher. (default) DCU IP Prefetcher Disables the DCU IP Prefetcher. - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 101
mode for Intel processors. APML Enable the Advanced Platform Management Link mode for AMD processors. CPU Power Capping To decide the highest processor performance state in the OS. (P0-state). CPU Power Capping To decide the highest processor performance state in the OS. (P1-state). CPU - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 102
4814 4815 4816 4817 4820 4821 4822 Setup Option L3 Cache Power Control L3 Cache Power Control C7 State C7 State Non Coherent HT Link Width Non Speed Non Coherent HT Link Speed Memory Turbo Mode Memory Turbo Mode NUMA Support Description Disable the clock stop for an idle subcache. Enable the clock - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 103
Table 2-1. D4 Token Table (continued) Token 4823 4824 4825 4826 4827 4828 4829 482A 482B 482C 482D 482E 482F 4830 Setup Option Description Memory Frequency Detects the memory running speed from H/W designed (SPD, memory population). Memory Frequency Sets memory running speed up to 800MHz. - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 104
the SATA link rate at minimum rate speed of Link Rate 1.5 Gbps. For power consumption. Embedded SATA Sets the SATA link rate at minimum rate speed of Link Rate 3.0 Gbps. PCIe Slot ASPM Controls the level of ASPM supported on the PCI Express Link of port. All entry disabled. PCIe Slot ASPM - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 105
Maximum Payload Size Maximum Payload Size Maximum Payload Size WHEA Support WHEA Support NIC Enumeration Description Controls the level of ASPM supported to onboard LAN. L0s entry downstream enabled. Controls the level of ASPM supported to onboard LAN. L0s entry downstream and L1 enabled. Controls - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 106
Table 2-1. D4 Token Table (continued) Token 485A 485B 485C 485D 485E 485F 4860 4861 4870 4871 4873 4877 4878 4879 Setup Option Description NIC Enumeration Sets PXE boot from Add-on NIC adapter to onboard NIC. PCIe Generation Sets the PCI signaling rate at Gen3 8.0 Gigabits bandwidth. PCIe - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 107
as the first boot device. Sets RAID as the first boot device. Sets a USB storage device as the first boot device. Sets a CD/DVD ROM as the first boot device the 2nd boot device. Sets RAID as the 2nd boot device. Sets a USB storage device as the 2nd boot device. Sets the CD/DVD ROM as the 2nd boot - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 108
Device Sets RAID as the 5th boot device. 5th Boot Device Sets a USB storage device as the 5th boot device. 5th Boot Device Sets the CD/DVD . IPv6 Mode Disables IPv6 internet protocol support. IPv6 Mode Enables IPv6 internet protocol support. IPv6 AutoConfig Disables IPv6 auto configuration. - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 109
VT-UTF8 Combination Key Support for Key Support ANSI/VT100 terminals. VT-UTF8 Combo Enables VT-UTF8 Combination Key Support for Key Support ANSI/VT100 terminals. Efficient Controls the energy efficient policy as low power Policy profile to configure all necessary settings. Using the System - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 110
boot. N/A Requests a energy efficiency settings of SETUP values on the next boot. N/A Requests HPCC efficiency settings of SETUP values on the next boot. Dell will provide the settings before A-can BIOS. Shell Requests the uEFI Shell as first boot device on the next boot. N/A Use NIC3 as - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 111
Table 2-1. D4 Token Table (continued) Token 48E7 48E8 48E9 48EA 48EB 48EC 48ED 48EE 48EF 48F0 48F1 48F2 48F3 48F4 48F5 48F6 Setup Option N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Description Use HDD2 as the 1st PXE boot device on the next boot. Use HDD3 as the 1st PXE boot - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 112
Table 2-1. D4 Token Table (continued) Token 48F7 48F8 48F9 48FA 48FB Setup Option N/A N/A N/A N/A N/A Description Use RAID HDD12 as the 1st PXE boot device on the next boot. Use RAID HDD13 as the 1st PXE boot device on the next boot. Use RAID HDD14 as the 1st PXE boot device on the next boot. Use - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 113
spec and is implemented. • O = Optional command supported in this implementation. • N = Not supported in this implementation. See the Deployment Toolkit Version 1.3 User's Guide On Get ACPI Power State Get Device GUID Get NetFn Support Get Command Support Get Command Sub-function Support NetFn App - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 114
Enables App Get Command Enables App Set Command Sub-function Enables App Get Command Sub-function Enables App Get OEM NetFn IANA Support App Code 0x0C 0x0Dh 0x60h 0x61h 0x62h 0x63h 0x64h IPMI 2.0 BMC O Yes O Yes O Yes O Yes O Yes O Yes O Yes Table 2-3. BMC Watchdog Timer - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 115
06H) (continued) Command Get BT Interface Capabilities Get System GUID Set System Info Parameters Get System Info Parameters Get Channel Instance Info Command Set User Payload Access Get User Payload Access Get Channel Payload Support NetFn App App App App App App App App App App App App App - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 116
Panel Button Enable Set Power Cycle Interval Get POH Counter NetFn Code Chassis 0x00h Chassis 0x01h Chassis 0x02h Chassis 0x03h Chassis 0x04h Chassis 0x05h Chassis 0x06h Chassis 0x07h Chassis 0x08h Chassis 0x09h Chassis 0x0Ah Chassis 0x0Bh Chassis 0x0Fh IPMI2.0 M M M O O O O O O O O O O BMC Yes - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 117
Table 2-7. Event Commands (NetFn: 0x04H) Command Set Event Receiver Get Event Receiver Platform Event NetFn S/E S/E S/E Code 0x00h 0x01h 0x02h IPMI2.0 M M M BMC Yes Yes Yes Table 2-8. PEF/PET Alerting Commands (NetFn: 0x04H) Command Get PEF Capabilities Arm PEF Postpone Timer Set PEF - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 118
SDR Repository Get SDR Add SDR Partial ADD SDR Delete SDR Clear SDR Repository Get SDR Repository Time NetFn Storage Storage Storage Storage Storage Storage Storage Storage Storage Code 0x20h 0x21h 0x22h 0x23h 0x24h 0x25h 0x26h 0x27h 0x28h IPMI2.0 M O M M M O O M O BMC Yes No Yes Yes No Yes No - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 119
0x46h O Clear SEL Storage 0x47h M Get SEL Time Storage 0x48h M Set SEL Time Storage 0x49h M Get Auxiliary Log Status Storage 0x5Ah O Set Auxiliary Log Status Storage 0x5Bh O Get SEL Time UTC Offset Storage 0x5Ch O Set SEL Time UTC Offset Storage 0x5D O * Support for Partial Add SEL - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 120
Device Commands (NetFn: 0x0CH) Command Set LAN Configuration Parameters (Note: Parameter 9 and 25 are not supported.) Get LAN Configuration Parameters (Note: Parameter 9 and 25 are not supported.) Suspend BMC ARP Get IP/UDP/RMCP Statistics NetFn Code Transport 0x01h Transport 0x02h Transport 0x03h - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 121
Table 2-16. Command Forwarding Commands (NetFn: 0x0CH) Command Forwarded Command Set Forwarded Commands Get Forwarded Commands Enable Forwarded Commands NetFn Code Transport 0x30h Transport 0x31h Transport 0x32h Transport 0x33h IPMI2.0 O O O O BMC Yes Yes Yes Yes Table 2-17. Firmware Update - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 122
system performance. The following table provides a guide for power management settings. Table 2-19. Power Management Settings System Setup Setup Page Power Management Maximum Performance (48DB) Setting Option D4 Token Power Management Max. 021F Performance Energy Efficiency Policy - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 123
Setup Setup Page Setting Memory Memory Frequency Configuration Memory Turbo Mode Memory Throttling Mode Memory Operating Voltage SATA Configuration Power Saving Features PCI PCIe Slot ASPM Configuration Onboard LAN ASPM Mezzing Slot ASPM Maximum Performance (48DB) Option D4 Token - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 124
124 Using the System Setup Program - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 125
only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 126
• Some cables have a connector with locking tabs; if you are disconnecting this type of cable, press in on the locking tabs before you disconnect the cable. As you pull connectors apart, keep them evenly aligned to avoid bending any connector pins. Also, before you connect a cable, ensure that both - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 127
should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized is not covered by warranty. Read and follow the safety instructions that came with - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 128
10-Sled and 8-Sled configuration. A mixture of differing sled types is also supported in the PowerEdge C8000 server enclosure. For more information, refer to the PowerEdge C8000 Hardware Owner's Manual. Figure 3-2. PowerEdge C8220 10-Sled SKU Figure 3-3. PowerEdge C8220 8-Sled SKU with 2 Power Sleds - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 129
of time without a sled blank installed can cause the PowerEdge C8000 server enclosure to overheat. See "Installing a Sled Blank" on page 131. 1 Power down the sled using OS commands or the Baseboard Management Controller, and ensure that the sled's power is off. When a sled is powered off, its front - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 130
service and support team. Damage due to servicing that is not authorized is not covered by warranty. Read and follow the safety instructions that came with the product. 1 Orient the sled so that the release latch is in the bottom of the sled. See Figure 3-4. 2 Slide the new sled into the enclosure - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 131
with the guide rail facing forward. Slide the blank into the enclosure until it is fully seated and the release latches snap into place. See Figure 3-5. SD Card Removing a SD Card 1 Power down the sled using OS commands or the Baseboard Management Controller, and ensure that the sled's power is off - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 132
should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized is not covered by warranty. Read and follow the safety instructions that came with - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 133
of the system. 1 Check that all cable connections are secure. 2 Place the front cover on top of the sled tray, aligning the notches in the front cover with the corresponding tabs in the sled tray. See Figure 3-7. 3 If an expansion card is installed, make sure the expansion card riser is firmly - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 134
should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized is not covered by warranty. Read and follow the safety instructions that came with - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 135
should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized is not covered by warranty. Read and follow the safety instructions that came with - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 136
should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized is not covered by warranty. Read and follow the safety instructions that came with - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 137
directed by the online or telephone service and support team. Damage due to servicing that is not authorized is not covered by warranty. Read and follow the safety instructions that came with the product. 1 Remove the sled from the enclosure. See "Removing a Sled" on page 129. 2 Remove the cooling - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 138
Figure 3-10. Heat Sink Screw Loosening Sequence 5 Gently lift the heat sink off the processor and set the heat sink aside with thermal grease side facing up. See Figure 3-11. Figure 3-11. Removing and Installing the Heat Sink 138 Installing System Components - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 139
should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized is not covered by warranty. Read and follow the safety instructions that came with - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 140
directed by the online or telephone service and support team. Damage due to servicing that is not authorized is not covered by warranty. Read and follow the safety instructions that came with the product. 1 Remove the sled from the enclosure. See "Removing a Sled" on page 129. 2 Remove the cooling - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 141
3 Remove the heat sink. See "Removing a Heat Sink" on page 137. CAUTION: The processor is held in its socket under strong pressure. Be aware that the release lever can spring up suddenly if not firmly grasped. 4 Position your thumb firmly over the processor hook-shaped socket-release lever and - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 142
should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized is not covered by warranty. Read and follow the safety instructions that came with - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 143
DIMMs (RDIMMs), and load reduced DIMMs (LRDIMMs) to support processor 1 and processor 2. See "System Board Connectors" on Installation Guidelines Follow these guidelines when installing memory modules on the sled system board. • Use only Dell approved R/LR/UDIMM DDR3 memory modules in 2 GB, 4 - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 144
• Memory sparing and memory mirroring are supported on the sled system board. Memory sparing requires that all the for each other, identical DIMMs must be installed in the same slots across both channels. Supported DIMM Configuration For the sequence of the 16 DIMM sockets, see Figure 3-13. When you - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 145
Table 3-2. Memory Module Configuration-Single Processor DIMM QTY Channel A DIMM A1 A5 1 2 3 4 6 8 Processor 1 Channel B DIMM A2 A6 Channel C DIMM A3 A7 Channel D DIMM A4 - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 146
should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized is not covered by warranty. Read and follow the safety instructions that came with - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 147
Installing Memory Modules 1 Press down and out on the ejectors on each end of the memory module socket. See Figure 3-15. 2 Align the memory module correctly with the alignment key of the memory module socket. See Figure 3-15. 3 Press down firmly on the memory module with your thumbs until the module - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 148
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized is not covered by warranty. Read and follow the safety instructions that came with the product. The sled - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 149
the system board. 1 Unpack the expansion card and prepare it for installation. For instructions, see the documentation accompanying the card. 2 Hold the card by its edges, the Front Cover" on page 133. 6 Replace the sled. See "Installing a Sled" on page 130. Installing System Components 149 - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 150
the online or telephone service and support team. Damage due to servicing that is not authorized is not covered by warranty. Read and follow the safety instructions that came with the product. Removing the Expansion Card Riser 1 Remove the sled from the enclosure. See "Removing a Sled" on page 129 - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 151
should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized is not covered by warranty. Read and follow the safety instructions that came with - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 152
Figure 3-18. Removing and Installing the Infiniband Mezzanine Card Assembly 1 screws (2) 2 Infiniband mezzanine card assembly 5 Remove the screw securing the mezzanine card bridge board to the bracket. See Figure 3-19. 6 Pull the mezzanine card bridge board away from the mezzanine slot. See - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 153
Figure 3-19. Removing and Installing the Mezzanine Card Bridge Board 1 2 3 1 screw 3 bracket 2 mezzanine card bridge board 7 Remove the three screws securing the Infiniband mezzanine card to the bracket. See Figure 3-20. 8 Remove the Infiniband mezzanine card from the bracket. See Figure 3-20. - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 154
should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized is not covered by warranty. Read and follow the safety instructions that came with - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 155
as directed by the online or telephone service and support team. Damage due to servicing that is not authorized is not covered by warranty. Read and follow the safety instructions that came with the product. 1 Remove the sled from the enclosure. See "Removing a Sled" on page 129. 2 Remove the front - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 156
1 screws (2) 2 10 GbE mezzanine card assembly 5 Remove the screw securing the mezzanine card bridge board to the bracket. See Figure 3-22. 6 Pull the mezzanine card bridge board away from the mezzanine slot. See Figure 3-22. Figure 3-22. Removing and Installing the Mezzanine Card Bridge Board 1 - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 157
should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized is not covered by warranty. Read and follow the safety instructions that came with - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 158
as directed by the online or telephone service and support team. Damage due to servicing that is not authorized is not covered by warranty. Read and follow the safety instructions that came with the product. 1 Remove the sled from the enclosure. See "Removing a Sled" on page 129. 2 Remove the front - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 159
. See Figure 3-25. 6 Remove the two screws securing the SD card reader. See Figure 3-25. 7 Lift the SD card reader from the SD card reader support bracket. See Figure 3-25. Installing System Components 159 - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 160
should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized is not covered by warranty. Read and follow the safety instructions that came with - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 161
the front cover. See "Installing the Front Cover" on page 133. 7 Replace the sled. See "Installing a Sled" on page 130. Removing the SD Card Reader Support Bracket 1 Remove the sled from the enclosure. See "Removing a Sled" on page 129. 2 Remove the front cover. See "Removing the Front Cover" on - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 162
service and support team. Damage due to servicing that is not authorized is not covered by warranty. Read and follow the safety instructions that came with the product. CAUTION: Combining SATA and SAS hard-drives in the same sled configuration is not supported. 1 Remove the sled from the enclosure - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 163
should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized is not covered by warranty. Read and follow the safety instructions that came with - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 164
should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized is not covered by warranty. Read and follow the safety instructions that came with - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 165
as directed by the online or telephone service and support team. Damage due to servicing that is not authorized is not covered by warranty. Read and follow the safety instructions that came with the product. 1 Remove the sled from the enclosure. See "Removing a Sled" on page 129. 2 Remove the back - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 166
should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized is not covered by warranty. Read and follow the safety instructions that came with - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 167
as directed by the online or telephone service and support team. Damage due to servicing that is not authorized is not covered by warranty. Read and follow the safety instructions that came with the product. 1 Remove the sled from the enclosure. See "Removing a Sled" on page 129. 2 Remove the back - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 168
should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized is not covered by warranty. Read and follow the safety instructions that came with - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 169
as directed by the online or telephone service and support team. Damage due to servicing that is not authorized is not covered by warranty. Read and follow the safety instructions that came with the product. 1 Remove the sled from the enclosure. See "Removing a Sled" on page 129. 2 Remove the back - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 170
should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized is not covered by warranty. Read and follow the safety instructions that came with - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 171
as directed by the online or telephone service and support team. Damage due to servicing that is not authorized is not covered by warranty. Read and follow the safety instructions that came with the product. 1 Remove the sled from the enclosure. See "Removing a Sled" on page 129. 2 Remove the front - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 172
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized is not covered by warranty. Read and follow the safety instructions the sled. See "Installing a Sled" on - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 173
as directed by the online or telephone service and support team. Damage due to servicing that is not authorized is not covered by warranty. Read and follow the safety instructions that came with the product. 1 Remove the sled from the enclosure. See "Removing a Sled" on page 129. 2 Remove the front - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 174
the system board. See Figure 3-33. When you disconnect the power cable, press down the cable-locking tab and disconnect the power cable from the NPDB. See Figure 3-33. Note the routing of the cables as you remove it from the sled tray. You must route these cables properly when you replace them - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 175
should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized is not covered by warranty. Read and follow the safety instructions that came with - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 176
sled tray to prevent them from being pinched or crimped. 6 Install the node power distribution board. See "Installing the Node Power Carrier" on page 163. 10 Install the SD card reader support bracket. See "Installing the SD Card Reader Support Bracket" on page 162. 11 Install the SD card reader. - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 177
support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product. Installation Problems Perform the following checks if you are troubleshooting an installation problem: • Check all cable and power - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 178
Connections Ensure that all external cables are securely attached to the external connectors on your sled before troubleshooting any external devices. See Figure 1-1 for the front-panel connectors on the sled. Troubleshooting the Video Subsystem 1 Check the sled and power connections to the monitor - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 179
see "System Board Jumper Settings" on page 195 for instructions on setting the NVRAM Clear jumper inside your system power up the device. If the problem persists, replace the device. If all troubleshooting fails, see "Getting Help" on page 203. Troubleshooting a Serial I/O Device 1 Turn off the sled - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 180
Troubleshooting a NIC 1 Restart the sled and check for any system messages pertaining to the NIC controller. 2 Check the appropriate indicator on the NIC all network cables are of the proper type and do not exceed the maximum length. If all troubleshooting fails, see "Getting Help" on page 203. 180 - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 181
Let the sled dry thoroughly for at least 24 hours. 8 Reinstall all server enclosure components. See the PowerEdge C8000 Systems Hardware Owner's Manual for more information. 9 Reinstall all sled components you removed in step 5. 10 Close the sled. See "Sled Covers" on page 132. Troubleshooting 181 - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 182
service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product. 1 Turn off the sleds and attached peripherals. 2 Disconnect the enclosure from the electrical outlet or the PDU - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 183
service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product. NOTE: The fan modules are hot-swappable. Remove and replace only one fan module at a time in the server enclosure - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 184
remove it. 4 Reseat the faulty fan. See the PowerEdge C8000 Hardware's Owner Manual for more information. 5 If none of the fan indicators show a fault LED and the blades do not power on, log into the BMC web interface and check for status messages. 6 If the problem is not resolved, install a new - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 185
PSU module is faulty the status indicator lights up amber. 2 Replace the faulty PSU module in the power sled. See the PowerEdge C8000 Systems Hardware Owner's Manual for more information. NOTE: After installing a power sled with a new PSU module, allow several seconds for the system to recognize the - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 186
settings, if needed. If the memory settings match the installed memory but a problem is still indicated, go to step 13. 4 Turn off the sled and attached peripherals. 5 Remove the sled from the enclosure. See "Removing a Sled" on page 129. 6 Remove the cooling shroud. See "Removing the Cooling Shroud - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 187
or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product. CAUTION: This troubleshooting procedure can destroy data stored on the hard - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 188
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product. 4 Turn off the sled and attached peripherals. 5 Remove the sled from the enclosure. See "Removing a Sled" on - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 189
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product. 1 Turn off the sled and attached peripherals. 2 Remove the sled from the enclosure. See "Removing a Sled" on - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 190
service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product. 1 Turn off the sled and attached peripherals. 2 Remove the sled from the server enclosure. See "Removing a Sled - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 191
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product. 1 Remove the sled from the enclosure. See "Removing a Sled" on page 129. 2 Open the sled. See "Sled Covers - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 192
only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 193
IRQ14 Primary IDE controller IRQ7 PCI IRQ pool definition IRQ15 Secondary IDE controller PCI IRQ pool definition is the BIOS code assigned at run time. Troubleshooting 193 - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 194
194 Troubleshooting - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 195
boards in the system. System Board Jumper Settings Figure 5-1. System Board Jumper Settings Table 5-1. System Board Jumper Settings Item Jumper 1 Service mode Setting Description (default) The flash security setting is enabled. The flash security and NVRAM clear signal is disabled. Jumpers - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 196
recovery jumper enables the BIOS flash memory special recovery mode. (default) The password feature is enabled. The password feature is disabled. 6 Power button pass (default) The BMC triggers a power button signal. The power button passthrough signal is triggered. 196 Jumpers and Connectors - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 197
internal serial connector 17 PCIe x16 back GPGPU 2 PCIe x8 mezzanine slot 4 internal SAS mezzanine slot 6 onboard SATA connector 4 8 system battery 10 processor 1 12 main power connector 14 SGPIO connector 2 16 front panel connector 1 18 processor 2 Jumpers and Connectors 197 - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 198
socket DIMMA2 socket DIMMA5 socket DIMMA6 socket 21 LAN LED connector 22 PCIe x16 slot 1 23 PCIe x16 slot 2 24 SGPIO connector 1 25 power button/power-on indicator 26 VGA connector 27 serial connector 28 internal BMC serial console connector 29 BMC management port 30 consolidated BMC cable - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 199
Interposer Extender Connectors Figure 5-3. Interposer Extender Connectors 1 SATA connector 4 3 SATA connector 5 5 SGPIO connector 7 SATA connector 1 9 SATA connector 3 2 2-pin power connector 4 IPMB connector 6 SATA connector 0 8 SATA connector 2 Jumpers and Connectors 199 - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 200
SD Card Reader Connectors Figure 5-4. SD Card Reader Connectors 1 SD card reader cable connector 2 SD card connector 200 Jumpers and Connectors - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 201
Distribution Board Connectors Figure 5-5. Node Power Distribution Board Connectors 1 power/throttle connector 3 12V S2 power connector 5 power connector 7 HDD2 power connector 9 12 V S1 power connector 11 hard-drive LED indicator connector 13 LAN pass-through connector 2 I2C connector - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 202
202 Jumpers and Connectors - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 203
provides several online and telephone-based support and service options. Availability varies by country and product, and some services may not be available in your area. To contact Dell for sales, technical support, or customer service issues: 1 Visit support.dell.com. 2 Click your country/region at - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 204
204 Getting Help - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 205
FILE LOCATION: D:\Projects\User Guide\Server\Dell\Zeus\HOM\SWC Sled\for Dell\C8220\C8220_HOM_bk0IX.fm Index A about your system, 11 B back cover installing, 135 removing, 134 C command line interfaces, 90 connectors system board, 197 console redirection configuring, - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 206
FILE LOCATION: D:\Projects\User Guide\Server\Dell\Zeus\HOM\SWC Sled\for Dell\C8220\C8220_HOM_bk0IX.fm hard-drive tray installing, 166 removing, 165 heat sink installing, 139 removing, 137 I indicator front panel, 12 NIC, 14 power, 13 system identity, 13 indicator codes power and system board, 16 - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 207
LOCATION: D:\Projects\User Guide\Server\Dell\Zeus\HOM\SWC Sled\for Dell\C8220\C8220_HOM_bk0IX.fm P POST error codes, 19 power management settings, 122 removing, 161 service tag, 18 sled front features, 12 installing, 130 removing, 129 sled blank installing, 131 removing, 130 sled front features, - Dell PowerEdge C8000 | Dell PowerEdge C8220 Hardware Owner's Manual - Page 208
86 exit, 88 main, 52 security, 78 server, 80 T troubleshooting damaged enclosure, 182 enclosure fan modules, 183 expansion cards, 189 external connections, 178 hard-drive, 187 power sled, 185 processors, 190 RTC battery, 192 serial device, 179 storage controller, 188 system board, 191 system memory
Dell PowerEdge C8220
Hardware Owner’s
Manual
Regulatory Model: B05B
Regulatory Type: B05B001