Dell PowerVault 110T DLT VS160 Media Handbook - Page 19
Media with bent-in leader buckles have been known to cause the tape drive to drop the leader - dlt tape drive
View all Dell PowerVault 110T DLT VS160 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 19 highlights
Figure 1-29. SDLT Bent-In Leader Buckles bar hooks Media with bent-in leader buckles have been known to cause the tape drive to drop the leader when the drive tries to load the media into the take-up reel. Cartridge Storage When storing cartridge, avoid moisture and direct sunlight. Exposure to moisture or sunlight can deform or ruin media. Table 1-6. Normal Storage Conditions (Nonarchival) Temperature • Between 61ºF and 90ºF (16ºC and 32ºC) • Wet bulb temperature 78ºF (26ºC) Relative Humidity Between 20% and 80% Table 1-7. Archival Storage Conditions (for one or more years) Temperature Between 64ºF and 79ºF (18ºC and 26ºC) Relative Humidity Between 40% and 60% Dell PowerVault DLT, VS, and SDLT Media Handbook Version 2.0 17
Dell PowerVault DLT, VS, and SDLT Media Handbook Version 2.0
17
Figure 1-29.
SDLT Bent-In Leader Buckles
Media with bent-in leader buckles have been known to cause the tape drive to drop the leader
when the drive tries to load the media into the take-up reel.
Cartridge Storage
When storing cartridge, avoid moisture and direct sunlight. Exposure to moisture or sunlight
can deform or ruin media.
Table 1-6.
Normal Storage Conditions (Nonarchival)
Temperature
Relative Humidity
•
Between 61ºF and 90ºF (16ºC and 32ºC)
•
Wet bulb temperature 78ºF (26ºC)
Between 20% and 80%
Table 1-7.
Archival Storage Conditions (for one or more years)
Temperature
Relative Humidity
Between 64ºF and 79ºF (18ºC and 26ºC)
Between 40% and 60%
hooks