Denon AVR 2807 Serial Protocol - Page 15

Zone3 Output Mute On/off Change

Page 15 highlights

EVENT PARAMETER function MU ON OUTPUT MUTE ON/OFF change OFF ZM ON MAIN-ZONE ON/OFF change OFF Z2 PHONO MULTI ZONE-2 source change | ---The name of PARAMETER is V.AUX the same as that of the time of SI COMMAND. SOURCE MULTI ZONE-2 mode cancel ** MULTI ZONE-2 VOLUME change , **:10 to 99 by ASCII 98 = +18dB(MAX) 80 = 0dB 10 = -70dB 99 = ---(MIN) (Power Amp Assign=ZONE2 Only) ON MULTI ZONE-2 ON/OFF change OFF Z2MU ON ZONE2 OUTPUT MUTE ON/OFF change OFF Z3 PHONO MULTI ZONE-3 source change | ---The name of PARAMETER is V.AUX the same as that of the time of SI COMMAND. SOURCE MULTI ZONE-3 mode cancel ** MULTI ZONE-3 VOLUME change , **:10 to 99 by ASCII 98 = +18dB(MAX) 80 = 0dB 10 = -70dB 99 = ---(MIN) ON MULTI ZONE-3 ON/OFF change OFF Z3MU ON ZONE3 OUTPUT MUTE ON/OFF change OFF The '*' PARAMETER of Z2, Z3 EVENT : Uses two ASCII characters. (see page4 J) section) example MUON MUOFF ZMON ZMOFF Z2PHONO | Z2V.AUX Z2SOURCE Z280 Z2ON Z2OFF Z2MUON Z2MUOFF Z3PHONO | Z3V.AUX Z3SOURCE Z380 Z3ON Z3OFF Z3MUON Z3MUOFF - 15 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22

- 15 -
EVENT
PARAMETER
function
example
MU
ON
OUTPUT MUTE ON/OFF change
MUON<CR>
OFF
MUOFF<CR>
ZM
ON
MAIN-ZONE ON/OFF change
ZMON<CR>
OFF
ZMOFF<CR>
Z2
PHONO
MULTI ZONE-2 source change
Z2PHONO<CR>
|
---The name of PARAMETER is
|
V.AUX
the same as that of the time of SI COMMAND.
Z2V.AUX<CR>
SOURCE
MULTI ZONE-2 mode cancel
Z2SOURCE<CR>
**
MULTI ZONE-2 VOLUME change , **:10 to 99 by ASCII
Z280<CR>
98 = +18dB(MAX)
80 = 0dB
10 = -70dB
99 = ---(MIN)
(Power Amp Assign=ZONE2 Only)
ON
MULTI ZONE-2 ON/OFF change
Z2ON<CR>
OFF
Z2OFF<CR>
Z2MU
ON
ZONE2 OUTPUT MUTE ON/OFF change
Z2MUON<CR>
OFF
Z2MUOFF<CR>
Z3
PHONO
MULTI ZONE-3 source change
Z3PHONO<CR>
|
---The name of PARAMETER is
|
V.AUX
the same as that of the time of SI COMMAND.
Z3V.AUX<CR>
SOURCE
MULTI ZONE-3 mode cancel
Z3SOURCE<CR>
**
MULTI ZONE-3 VOLUME change , **:10 to 99 by ASCII
Z380<CR>
98 = +18dB(MAX)
80 = 0dB
10 = -70dB
99 = ---(MIN)
ON
MULTI ZONE-3 ON/OFF change
Z3ON<CR>
OFF
Z3OFF<CR>
Z3MU
ON
ZONE3 OUTPUT MUTE ON/OFF change
Z3MUON<CR>
OFF
Z3MUOFF<CR>
The '*'
PARAMETER
of Z2, Z3
EVENT
: Uses two ASCII characters. (see page4 J) section)