Denon AVR 4806 Serial Protocol - Page 8

Sidbs<cr&gt, Cdr/tape, Sicdr/tape<cr&gt, Z2cdr/tape

Page 8 highlights

COMMAND PARAMETER function CV SB UP ---SURROUND BACKch (SBch 1SP) SB DOWN SB ** **:00 to 99 by ASCII , 50=0dB MU ON OUTPUT MUTE ON/OFF change OFF SI PHONO Select INPUT source CD TUNER DVD VDP TV DBS VCR-1 VCR-2 VCR-3 V.AUX CDR/TAPE ZM ON MAIN-ZONE ON/OFF change at AVR-4806 OFF Z2 PHONO MULTI ZONE-2 mode set , and select source at AVR-4806 | CDR/TAPE ---The name of PARAMETER is the same as that of the time of SI COMMAND. SOURCE MULTI ZONE-2 mode cancel at AVR-4806 UP MULTI ZONE-2 VOLUME UP/DOWN , direct change to **dB DOWN at AVR-4806 ** **:10 to 99 by ASCII , 80=0dB, 99=---(MIN) ON MULTI ZONE-2 ON/OFF change at AVR-4806 OFF Z2MU ON ZONE2 OUTPUT MUTE ON/OFF change OFF CV , Z2 COMMAND : "*" parameter uses two ASCII characters. (see page4 J) section) example CVSB UP CVSB DOWN CVSB 50 MUON MUOFF SIPHONO SICD SITUNER SIDVD SIVDP SITV SIDBS SIVCR-1 SIVCR-2 SIVCR-3 SIV.AUX SICDR/TAPE ZMON ZMOFF Z2PHONO | Z2CDR/TAPE Z2SOURCE Z2UP Z2DOWN Z280 Z2ON Z2OFF Z2MUON Z2MUOFF - 8 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18

- 8 -
COMMAND
PARAMETER
function
example
CV
SB UP
---SURROUND BACKch
(SBch 1SP)
CVSB UP<CR>
SB DOWN
CVSB DOWN<CR>
SB **
**:00 to 99 by ASCII , 50=0dB
CVSB 50<CR>
MU
ON
OUTPUT MUTE ON/OFF change
MUON<CR>
OFF
MUOFF<CR>
SI
PHONO
Select INPUT source
SIPHONO<CR>
CD
SICD<CR>
TUNER
SITUNER<CR>
DVD
SIDVD<CR>
VDP
SIVDP<CR>
TV
SITV<CR>
DBS
SIDBS<CR>
VCR-1
SIVCR-1<CR>
VCR-2
SIVCR-2<CR>
VCR-3
SIVCR-3<CR>
V.AUX
SIV.AUX<CR>
CDR/TAPE
SICDR/TAPE<CR>
ZM
ON
MAIN-ZONE ON/OFF change at AVR-4806
ZMON<CR>
OFF
ZMOFF<CR>
Z2
PHONO
MULTI ZONE-2 mode set , and select source at AVR-4806
Z2PHONO<CR>
|
---The name of PARAMETER is
|
CDR/TAPE
the same as that of the time of SI COMMAND.
Z2CDR/TAPE
SOURCE
MULTI ZONE-2 mode cancel at AVR-4806
Z2SOURCE<CR>
UP
MULTI ZONE-2 VOLUME UP/DOWN , direct change to **dB
Z2UP<CR>
DOWN
at AVR-4806
Z2DOWN<CR>
**
**:10 to 99 by ASCII , 80=0dB, 99=---(MIN)
Z280<CR>
ON
MULTI ZONE-2 ON/OFF change at AVR-4806
Z2ON<CR>
OFF
Z2OFF<CR>
Z2MU
ON
ZONE2 OUTPUT MUTE ON/OFF change
Z2MUON<CR>
OFF
Z2MUOFF<CR>
CV , Z2
COMMAND
: "*" parameter uses two
ASCII characters. (see page4 J) section)