    SERVICE DATA SHEET A06031201 FREEZER ICE MAKER - AUTOMATIC DEFROST BOTTOM FREEZER - R134a Refrigerator OP Open FF Cavity Thermistor Manual Defrost d F FF + WATER FILL SWITCH YELLOW P-2 CAUTION All electrical parts and wiring must be shielded from torch flame. DO NOT allow torch to touch
  • Electrolux E23BC69SPS | Wiring Diagram English - Page 2
    41 2 LT. BLU RED CONDENSER FAN FREEZER ICEMAKER WATER VALVE LT. BLU MAIN INLET WATER VALVE YEL BLK LT. BLU PIN 1 PIN BRN 4 WHT/BRN 3 WHT/BLU 2 WHT/BLU 1 WHT/BRN 4 WHT/BRN 3 WHT/BLU 2 WHT/BLU 1 REFRIGERATOR LEDS GRY 7 ORN 8 GRY 2 ORN 1 WHT/BRN WHT/BLU J1-3 J1-1 LED POWER BOARD 4 GRY 3
  • 1
  • 2

SERVICE DATA SHEET
A06031201
FREEZER ICE MAKER - AUTOMATIC DEFROST
BOTTOM FREEZER - R134a
POWER
ICE MAKER
I
CE MAKER
ICE MAKER
WATER VALVE
LINE
THERMAL
CUT-OUT
HOLD
SWITCH
THERMOSTAT
SHUTOFF
SWITCH
WATER FILL
SWITCH
MOLD HEATER
MOLD
MOUNTING
PLATE
165 WATTS
MOTOR
NEUTRAL
BLK
BLK
BLK
BLU
C
C
C
NO
NO
NO
NC
NC
NC
YELLOW
BRN
RED
GRN / YEL
RED
RED
LT. BLUE
P-3
P-1
P-2
P-4
ICE MAKER
LT. BLUE
IMPORTANT SAFETY NOTE
The information provided herein is designed to assist qualified repair personnel only. Untrained persons should not
attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before servicing this appliance.
IMPORTANT
If any green grounding wires are removed during servicing, they must be returned to their original position and
properly secured.
IMPORTANT: PLEASE RETURN THIS SHEET TO ITS ORIGINAL LOCATION.
PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT 37°/0°
CONTROL SETTING
Type A with Run / Start Capacitor
65°F (18°C) Ambient
90°F (32°C) Ambient
Operating Time
90 to 100%
100%
Freezer Temperature
-5° to 2°F
(-20° to -17°C)
-1° to 3°F
(-18° to -16°C)
Refrigerator Temperature
34° to 39°F
(1° to 4°C)
34° to 39°F
(1° to 4°C)
Low Side Pressure
-2 to 6 psig
(-14 to 41 kPa)
-2 to 6 psig
(-14 to 41 kPa)
High Side Pressure
(last 1/3 cycle)
85 to 105 psig
(586 to 724 kPa)
120 to 135 psig
(827 to 931 kPa)
Wattage (last 1/3 cycle)
30 to 50
50 to 70
Amps (running)
.4 to .8
.7 to .9
Base Voltage
115 vac (127 vac max)
DEFROST SPECIFICATIONS
Cabinet Size:
27’ & 28’ SD, 22’ CD
Thermal Cutout
Heater
Defrost
Heater
Termination
Cut-in
Cut-out
Watts
Ohms
Cut-out
110°F
(43.3°C)
135°F
(57.2°C)
500
26.5
48°F
(8°C)
CONDENSER FAN MOTOR
Watts
RPM
Amps
3.1
1100 CW
Opposite Shaft
0.03 Running
FREEZER ICE MAKER SPECIFICATIONS
Electrical
115 vac (127 vac max)
Thermostat
Opens at 48°F ( 9°C), Closes at 15° F ( -9°C)
Heater Voltage
115 vac
CAUTION
All electrical parts and wiring must be shielded from torch flame. DO NOT allow torch to
touch insulation; it will char at 200°F and flash ignite (burn) at 500°F. Excessive heat will
distort the plastic liner.
T
U
R
N
Mounting
Plate
Screws
Mounting
Plate
Screw
Motor
Gear
Timing
Gear
Water Fill
Adjustment
FREEZER ICE MAKER INFORMATION
(Where Applicable)
Test Cycling:
Remove cover by inserting screwdriver in notch at
bottom and prying cover from housing. Use screwdriver to rotate
motor gear counterclockwise until holding switch circuit is completed.
All components of ice maker should function to complete the cycle.
Water Fill Volume:
The water fill adjustment screw will change
the fill time. One full turn is equal to 20cc (.68 oz.). The correct fill
is 102 to 130cc (3.4 to 4.3 oz.). When a water valve is replaced,
the fill volume must be checked.
SYSTEM DIAGNOSTIC MODE
Activate:
Press
FZ
UP
and
FZ
DOWN
for up to 10 sec. simultaneously. Press
FF
UP
to advance through
tests.
Deactivate:
Press
FF
UP
for up to 10 sec. Diagnostic Mode will automatically deactivate after 5 min. of inactivity.
Note: Silence alarm.
• Tests marked with “*” may not be applicable to this unit and will not be displayed in System Diagnostic Mode.
• Tests displayed in diagnostic mode but not described below are for internal purposes only; advance through.
• View UI display for “on,” “off,” “CL,” “OP,” “SH,” “LO,” “HI” or numerical results of tests.
• Listen for operating sounds; feel for heat or air flow as appropriate to determine results of tests.
Test
To activate test:
Passing result
--
First Screen
--
Blank UI display, no LEDs illuminated.
--
Second Screen
--
All LED lights on UI illuminated.
--
Third Screen
--
Blank UI display, no LEDs illuminated.
46
Humidity Sensor
Activates automatically
“OP” if open, “SH” if short. AC Heater System: Displays %RH. DC
Heater System: “HI” - heater should be on. “Lo” - heater should be
off. %RH is displayed when humidity is between “Lo” and “HI” values;
heater could be on or off.
2
Freezer Defrost
Heater
Press power on-off
Freezer defrost heater on when “on”; off when “off”. Evaporator thermis-
tor temperature is flashed. Watch for temp increase with the heater on.
It may take a few minutes for the evaporator to heat up.
3
FF Lights powered
by external board
Press power on-off
FF lights on when “on”; off when “off”
12
Condenser Fan
Press power on-off
Fan running when “on”; stopped when “off”
41
Perfect Temp
Drawer (PTD)
Press power on-off
PTD UI illuminated when “on”; off when “off”
43
Mullion Anticonden-
sation Heater
Press power on-off
Flip Mullion Heater on when “on”; off when “off”
38
VCC Compressor
Press power on-off
Compressor on when “on”; off when “off”
15
Freezer Evapora-
tor Fan
Press power on-off
Press to toggle between “off”, “Lo” and “HI”. A current sensor reading is
flashed (units are not mA). OFF reading should be around 2. “Lo” speed
reading should settle down to around 9. “HI” speed reading should
settle down above 40.
20
FZ Lights
Press power on-off
FZ lights on when “on”; off when “off”
22
Damper
Press power on-off
With inspection mirror, observe damper open when “OP”; closed when “CL”
23
FF Door
Open/close FF door
“CL” on UI when door closed; “OP” when open
24
FZ Door
Open/close FZ door
“CL” on UI when door closed; “OP” when open
29
FF Thermistor
Activates automatically
UI shows temperature sensed by FF thermistor; pass if within 10°F of
temperature measured with gauge at FF thermistor location.
“OP” if open; “SH” if short
30
FZ Thermistor
Activates automatically
UI shows temperature sensed by FZ thermistor; pass if within 10°F of
temperature measured with gauge at FZ thermistor location.
“OP” if open; “SH” if short
33
Ambient Thermistor
@ Main Board
Activates automatically
UI shows temperature sensed at main board; pass if within +20°F/-10°F
of temperature measured with gauge at main board location.
“OP” if open; “SH” if short
34
Ambient Thermistor
@ UI
Activates automatically
UI shows temperature sensed at UI; pass if within +20°F/-10°F of tem-
perature measured with gauge at UI location. “OP” if open; “SH” if short
39
Freezer Evaporator
Thermistor
Activates automatically
UI shows temperature sensed by freezer evaporator thermistor; pass if
within 10°F of temperature measured with gauge at evaporator thermistor
location. “OP” if open; “SH” if short
0-
Firmware
Parameters
Press power on-off
Displays digit sequence; record
1-
Main Board
Firmware
Press power on-off
Displays digit sequence; record
3-
UI Firmware
Press power on-off
Displays digit sequence; record
ERROR CODES
SPECIAL MODES
Display
Interpretation
Mode
Display
Activate
Deactivate
FZ
FF
FZ
FF
(press for up to 10 sec. simultaneously)
--
OP
Open FF Cavity
Thermistor
Manual Defrost
d
F
FF
+
and FF -
Same to deactivate
OP
--
Open FZ Cavity
Thermistor
Demo / Showroom
77
77
FZ + and FF -
Unplug to deac-
tivate
--
SH
Shorted FZ Cavity
Thermistor
Sabbath
Sb
Sb
FZ - and
FF
-
Same to deactivate
SH
--
Shorted FZ Thermistor
System Diagnostic
Blank UI display,
no LEDs illumi-
nated
FZ + and FZ -
Press and hold FF
+
to deactivate
SY
CF
UI to Main Board com-
munication failure;
on start up
Current Air Temps
FZ
Temp
FF
Temp
Default Settings and
Temp Mode Buttons
Automatically after
10 seconds
SY
CE
UI to Main
Board com-
munication error;
after a
period of operation
Notes:
• Always check for pin back-outs, pinched or damaged wires before
replacing components.
• Determine whether failure is caused by the component, main control board or wiring.
Contact TID before replacing main control board.
• Refer to Service Manual for additional information.
SY
EF
Freezer Evaporator Fan
Failure
Service Mode For Perfect Temp™ Drawer
Activation
This mode is accessible only
when the drawer is in OFF
mode. Press and hold the
temperature decrease key (–)
and the temperature increase
key (+) for 5 seconds.
Deactivation
Press and hold the tempera-
ture (+) key for 5 seconds, or
no keys pressed in 5 minutes
returns to the OFF mode of
operation.
Test Operation
The up/down buttons
will be used to navigate
through the tests and
the ON/OFF button will
be used to initiate the
displayed test.
Fan Test
Display shows “F1”
for fan on or “F0” for
fan off.
Heater Test
Display shows “H1” for
heater ON or “H0” for
heater OFF.
Damper Test
Display shows “d1”
for damper open,
or “d0” for damper
closed. Damper
movement may take
30 seconds.
To Test Damper
1. Remove drawer.
2. Start damper test.
3. Observe damper
moving open and
closed.
4. Exit damper test.
Report NTC Temperature
Test
Display shows “b1” for
chamber sensor
test. The UI display will
show —°F until the main
board responds with asso-
ciated sensor temperature
reading.
Display Test
“L0” for display test. The
display test will cycle
through all the display seg-
ments with a minimal on
time for each segment.
Fault Codes Listed on Diagram Sheet
Check resistance between terminals 1 and
2, 2 and 3, 3 and 1.
If all resistances are equal,
compressor is operative.
VCC COMPRESSOR MOTOR RESISTANCE CHECK