Electrolux E23BC69SPS Wiring Diagram English - Page 1
Electrolux E23BC69SPS Manual
View all Electrolux E23BC69SPS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 1 highlights
PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT 37°/0° CONTROL SETTING Type A with Run / Start Capacitor 65°F (18°C) Ambient 90°F (32°C) Ambient Operating Time 90 to 100% 100% Freezer Temperature -5° to 2°F (-20° to -17°C) -1° to 3°F (-18° to -16°C) SERVICE DATA SHEET A06031201 FREEZER ICE MAKER - AUTOMATIC DEFROST BOTTOM FREEZER - R134a Refrigerator Temperature 34° to 39°F (1° to 4°C) 34° to 39°F (1° to 4°C) Low Side Pressure High Side Pressure (last 1/3 cycle) -2 to 6 psig (-14 to 41 kPa) 85 to 105 psig (586 to 724 kPa) -2 to 6 psig (-14 to 41 kPa) 120 to 135 psig (827 to 931 kPa) IMPORTANT: PLEASE RETURN THIS SHEET TO ITS ORIGINAL LOCATION. Wattage (last 1/3 cycle) Amps (running) Base Voltage 30 to 50 .4 to .8 115 vac (127 vac max) 50 to 70 .7 to .9 ERROR CODES Display Interpretation Mode SPECIAL MODES Display Activate Deactivate Cabinet Size: 27' & 28' SD, 22' CD Watts 3.1 Electrical Thermostat Heater Voltage LINE BLK P-3 THERMAL CUT-OUT DEFROST SPECIFICATIONS Thermal Cutout Heater Defrost Heater Termination Cut-in Cut-out Watts Ohms Cut-out 110°F 135°F 500 26.5 (43.3°C) (57.2°C) 48°F (8°C) CONDENSER FAN MOTOR RPM 1100 CW Opposite Shaft → Check at Athme cponsnector from the power cord harness into the inverter board, located in t(hPeURm0aa.nc0hd3inWeRHucTonwmniprineasgr)tment. Is Inverter Board receiving 115 VAC FREEZER ICE MAKER SPECIFICATIONfrSom power supply? 115 vac (127 vac max) no Opens at 48°F ( 9°C), Closes at 15° F ( -9°C) 115 vac POWER • Check voltage supply. • Check and repair power cord harness wiring and connections. NEUTRAL ICE MAKER BRN LT. BLUE ICE MAKER MOTOR RED HOLD SWITCH NO LT. BLUE RED C NC THERMOSTAT P-4 NO FZ FF FZ FF (press for up to 10 sec. simultaneously) -- OP Open FF Cavity Thermistor Manual Defrost d F FF + and FF - Same to deactivate OP -- Open FZ Cavity Thermistor Demo / Showroom 77 77 FZ + and FF - Unplug to deactivate -- SH Shorted FZ Cavity Thermistor Sabbath Sb Sb FZ - and FF - Same to deactivate SH -- Shorted FZ Thermistor System Diagnostic Blank UI display, FZ + and FZ - Press and hold FF + no LEDs illumi- to deactivate nated → CChomecpkreastSsIonYrverter BCoFard onUI to Main Board→ cRcooemmmpo-rveessinovreCarntuedrrcrbheoenxctkfrAoremisristThtaeenmceps FZ→ Check Board tcooFnCFnoemcptiroensDssoferrofamuIlnt vSeretettrings and Automatically after yes (BLK and RED wires) munication fyaeislure;across compressor winding pairs as Is Inverter Board receivoinngs1ta0r-t1u5p shown. yeTsempAre coTnenmepctionsTefrmomp IMnvoedrteerButtons 10 seconds Board to Compressor intact? VAC andS1Y-5 VDCCEfromUMIatoinMain Control Board? munication Board error; cIpsoaimrress-eisqtaunaclN?eoatceross:s all winding after a • Always check for pin back-outs, pinched or damaged wires before no period of operation noreplacing components. no SY EF Freezer Failure Evaporator FRIneavpnelartceer••CBooDCRmarpeedor.tfeneesrtrsmaotrocinatnSedTewIrDvhiecbteheeMfroafraneiluurareelpfioslarccaaiIwdundiedrsgeneisttdmiifooyrnbaapayniondlotirhrncecefpoooancnrinrometdmrcaatomiptolinaoobsgnneo.edanrt,dm. ain control board or wiring. between Inverter Board and → Check at Main Control Board Compressor. (BLK/WHT and RED/BLK wires) no yes Is Main Control Board sending Replace Main Control Board. 10-15 VAC and 1-5 VDC to Inverter Board? yes VCC COMPRESSOR MOTOR RESISTANCE CHECK VCC Resistance Check Replace Inverter Board Check resistance between terminals 1 and 2, 2 and 3, 3 and 1. Identify and repair damaged wires or If all resistances are equal, poor connections between Main Control compressor is operative. Board and Inverter Board. ICE MAKER BLK RED WATER VALVE BLK BLU NC C MOLD HEATER 165 WATTS SHUTOFF NO SWITCH GRN / YEL P-1 MOLD MOUNTING PLATE ICE MAKER NC C WATER FILL SWITCH YELLOW P-2 CAUTION All electrical parts and wiring must be shielded from torch flame. DO NOT allow torch to touch insulation; it will char at 200°F and flash ignite (burn) at 500°F. Excessive heat will distort the plastic liner. FREEZER ICE MAKER INFORMATION (Where Applicable) Test Cycling: Remove cover by inserting screwdriver in notch at bottom and prying cover from housing. Use screwdriver to rotate motor gear counterclockwise until holding switch circuit is completed. All components of ice maker should function to complete the cycle. Water Fill Adjustment Motor Gear N TUR Mounting Plate Screws Service Mode For Perfect Temp™ Drawer Activation This mode is accessible only when the drawer is in OFF mode. Press and hold the temperature decrease key (-) and the temperature increase key (+) for 5 seconds. Test Operation The up/down buttons will be used to navigate through the tests and the ON/OFF button will be used to initiate the displayed test. Damper Test Display shows "d1" for damper open, or "d0" for damper closed. Damper movement may take 30 seconds. Deactivation Press and hold the temperature (+) key for 5 seconds, or no keys pressed in 5 minutes returns to the OFF mode of operation. Fan Test Display shows "F1" for fan on or "F0" for fan off. Heater Test Display shows "H1" for heater ON or "H0" for heater OFF. To Test Damper 1. Remove drawer. 2. Start damper test. 3. Observe damper moving open and closed. 4. Exit damper test. Fault Codes Listed on Diagram Sheet Report NTC Temperature Test Display shows "b1" for chamber sensor test. The UI display will show -°F until the main board responds with associated sensor temperature reading. Display Test "L0" for display test. The display test will cycle through all the display segments with a minimal on time for each segment. Water Fill Volume: The water fill adjustment screw will change the fill time. One full turn is equal to 20cc (.68 oz.). The correct fill Mounting Plate is 102 to 130cc (3.4 to 4.3 oz.). When a water valve is replaced, Screw Timing the fill volume must be checked. Gear SYSTEM DIAGNOSTIC MODE Activate: Press FZ UP and FZ DOWN for up to 10 sec. simultaneously. Press FF UP to advance through tests. Deactivate: Press FF UP for up to 10 sec. Diagnostic Mode will automatically deactivate after 5 min. of inactivity. Note: Silence alarm. • Tests marked with "*" may not be applicable to this unit and will not be displayed in System Diagnostic Mode. • Tests displayed in diagnostic mode but not described below are for internal purposes only; advance through. • View UI display for "on," "off," "CL," "OP," "SH," "LO," "HI" or numerical results of tests. • Listen for operating sounds; feel for heat or air flow as appropriate to determine results of tests. Test To activate test: Passing result -- First Screen -- Blank UI display, no LEDs illuminated. -- Second Screen -- All LED lights on UI illuminated. -- Third Screen -- Blank UI display, no LEDs illuminated. 46 Humidity Sensor Activates automatically "OP" if open, "SH" if short. AC Heater System: Displays %RH. DC Heater System: "HI" - heater should be on. "Lo" - heater should be off. %RH is displayed when humidity is between "Lo" and "HI" values; heater could be on or off. 2 Freezer Defrost Heater Press power on-off Freezer defrost heater on when "on"; off when "off". Evaporator thermistor temperature is flashed. Watch for temp increase with the heater on. It may take a few minutes for the evaporator to heat up. 3 FF Lights powered Press power on-off by external board FF lights on when "on"; off when "off" 12 Condenser Fan Press power on-off Fan running when "on"; stopped when "off" 41 Perfect Temp Drawer (PTD) Press power on-off PTD UI illuminated when "on"; off when "off" 43 Mullion Anticonden- Press power on-off sation Heater Flip Mullion Heater on when "on"; off when "off" 38 VCC Compressor Press power on-off Compressor on when "on"; off when "off" 15 Freezer Evaporator Fan Press power on-off Press to toggle between "off", "Lo" and "HI". A current sensor reading is flashed (units are not mA). OFF reading should be around 2. "Lo" speed reading should settle down to around 9. "HI" speed reading should settle down above 40. 20 FZ Lights Press power on-off FZ lights on when "on"; off when "off" 22 Damper Press power on-off With inspection mirror, observe damper open when "OP"; closed when "CL" 23 FF Door Open/close FF door "CL" on UI when door closed; "OP" when open 24 FZ Door Open/close FZ door "CL" on UI when door closed; "OP" when open 29 FF Thermistor Activates automatically UI shows temperature sensed by FF thermistor; pass if within 10°F of temperature measured with gauge at FF thermistor location. "OP" if open; "SH" if short 30 FZ Thermistor Activates automatically UI shows temperature sensed by FZ thermistor; pass if within 10°F of temperature measured with gauge at FZ thermistor location. "OP" if open; "SH" if short 33 Ambient Thermistor Activates automatically UI shows temperature sensed at main board; pass if within +20°F/-10°F @ Main Board of temperature measured with gauge at main board location. "OP" if open; "SH" if short 34 Ambient Thermistor Activates automatically UI shows temperature sensed at UI; pass if within +20°F/-10°F of tem- @ UI perature measured with gauge at UI location. "OP" if open; "SH" if short 39 Freezer Evaporator Activates automatically UI shows temperature sensed by freezer evaporator thermistor; pass if Thermistor within 10°F of temperature measured with gauge at evaporator thermistor location. "OP" if open; "SH" if short 0- Firmware Parameters Press power on-off Displays digit sequence; record 1- Main Board Firmware Press power on-off Displays digit sequence; record 3- UI Firmware Press power on-off Displays digit sequence; record IMPORTANT SAFETY NOTE The information provided herein is designed to assist qualified repair personnel only. Untrained persons should not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before servicing this appliance. IMPORTANT If any green grounding wires are removed during servicing, they must be returned to their original position and properly secured.